Hyoung-Ki Lee

Hyoung-Ki Lee

Auto-generated profile, based on publicly available information

Hyoung-Ki Lee

Mayo Clin, Dept Radiol, 200 First St SW, Rochester, MN 55905 USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2014 in Ultrasonography
Verified
Journal Article
Open access
PDF file
WJWoo Kyoung Jeong
Woo Kyoung Jeong
HLHyo K. Lim
Hyo K. Lim
HLHyoung-Ki Lee
Hyoung-Ki Lee
JJJae Moon Jo
Jae Moon Jo
YKYongsoo Kim
Yongsoo Kim
Accurate assessment of the degree of liver fibrosis is important for estimating prognosis and deciding on an appropriate course of treatment for cases of chronic liver disease (CLD) with various etiologies. Because of the inherent limitations of liver biopsy, there is a great need for non-invasive and reliable tests that accurately estimate the degree of liver fibrosis. Ultrasound (US) elastography is considered a non-invasive, convenient, and precise technique to grade the degree of liver fibrosis by measuring liver stiffness. There are several commercial types of US elastography currently in use, namely, transient elastography, acoustic radiation force impulse imaging, supersonic shear-wave imaging, and real-time tissue elastography. Although the low reproducibility of measurements derived from operator-dependent performance remains a significant limitation of US elastography, this technique is nevertheless useful for diagnosing hepatic fibrosis in patients with CLD. Likewise, US elastography may also be used as a convenient surveillance method that can be performed by physicians at the patients' bedside to enable the estimation of the prognosis of patients with fatal complications related to CLD in a non-invasive manner.

24 February 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HLHyoung-Ki Lee
Hyoung-Ki Lee
DKDonggeon Kong
Donggeon Kong
KCKiwan Choi
Kiwan Choi
RMReem Mislati
Reem Mislati
MDMarvin M. Doyley
Marvin M. Doyley
We developed a new method, called the tangent plane method (TPM), for estimating 2D shear wave speed (SWS) from any direction of wave propagation more efficiently and accurately. In this technique, we estimate SWS by solving the Eikonal equation because this approach is more robust to noise. To further enhance performance, we computed the tangent plane of the arrival time surface. To evaluate the approach, we performed simulations and also conducted phantom studies. Simulation studies showed that TPM was more robust to noise than the conventional methods such as 2D CC (cross-correlation) and the distance method. Contrast/CNR for an inclusion (69kPa : manufacturer provided stiffness) of an inclusion phantom is 0.54/4.17, 0.54/1.82, and 0.46/1.22, respectively. SWS results (mean and standard deviation) were 4.41±0.49 m/sec, 4.62±0.85 m/sec, and 3.66±0.99 m/sec, respectively while the manufacturer’s reported value (mean and range) is 4.81±0.49 m/sec. This shows that TPM has the higher CNR and lower standard deviation than other methods. To increase computation speed, an iterative version of TPM (ITPM) was also developed, which calculated the time-of-flight iteratively. ITPM reduced the computation time to 3.6%, from 748 sec to 27 sec. In vivo case analysis demonstrated the feasibility of using the conventional ultrasound scanner for the proposed 2D SWS algorithms.

16 December 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HLHyoung-Ki Lee
Hyoung-Ki Lee
JGJames F. Greenleaf
James F. Greenleaf
MUMatthew W Urban
Matthew W Urban
Plane wave (PW) transmission has enabled multiple new applications, such as shear wave elastography, ultrafast Doppler imaging, and functional ultrasound imaging. PW compounding (PWC), which coherently sums the echo signals from multiple PW transmits with different angles, is widely used to improve B-mode image quality. When the motion between two speckle images is estimated, PWC suffers from an inherent displacement estimation error. This is derived theoretically and experimentally demonstrated in this work. We show that the phase difference between the acquired data with PW emissions with different angles is related to this error. When the absolute value of the phase difference is larger than $\pi $ /2, the displacement estimation error occurs. A new scheme, named initial-phase-compensated PWC (IPCPWC), is proposed, which compensates the phase of echo signals from each PW transmit and maintains the absolute value of the phase difference smaller than $\pi $ /2. The increased signal-to-noise ratio and reduced jitter of IPCPWC in motion data are demonstrated using tissue mimicking phantoms compared with PWC.

4 September 2023 in Ultrasonics
Verified
Journal Article
Closed access
PHPhilip M. Holmes
Philip M. Holmes
HLHyoung-Ki Lee
Hyoung-Ki Lee
MUMatthew W Urban
Matthew W Urban

11 November 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
HLHyoung-Ki Lee
Hyoung-Ki Lee
CCCharles B Capron
Charles B Capron
Hsiao-Chuan LiuHsiao-Chuan Liu
Hsiao-Chuan Liu
TRTuhin Roy
Tuhin Roy
MGMurthy N Guddati
Murthy N Guddati
MUMatthew W Urban
Matthew W Urban
Objective. Measuring waves induced with acoustic radiation force (ARF) in arteries has been studied over the last decade. To date, it remains a challenge to quantitatively assess the local arterial biomechanical properties. The cylindrical shape and waveguide behavior of waves propagating in the arterial wall pose complexities to determining the mechanical properties of the artery. Approach . In this paper, an artery-mimicking tube in water is examined utilizing three-dimensional measurements. The cross-section of the tube is measured while a transducer is translated over 41 different positions along the length of the tube. Motion in the radial direction is calculated using two components of motion which are measured from the two orthogonal views of the cross-section. This enables more accurate estimation of motion along the circumference of tube. Main results . The results provide more information to categorize the motion in tube wall into two types of responses: a transient response and a steady state response. The transient response is caused by ARF application and the waves travel along the length of the tube for a relatively short period of time. This corresponds to the axial and circumferential propagating waves. The two circumferential waves travel along the circumference of tube in CW (clockwise) and CCW (counter-clockwise) direction and result in a standing wave. By using a directional filter, the two waves were successfully separated, and their propagation was more clearly visualized. As a steady state response, a circumferential mode is generated showing a symmetric motion (i.e. the proximal and distal walls move in the opposite direction) following the transient response. Significance. This study provides a more comprehensive understanding of the waves produced in an artery-mimicking tube with ARF application, which will provide opportunities for improving measurement of arterial mechanical properties.

20 July 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
HLHyoung-Ki Lee
Hyoung-Ki Lee
PHPhilip M. Holmes
Philip M. Holmes
JGJames F. Greenleaf
James F. Greenleaf
MUMatthew W Urban
Matthew W Urban
Plane wave compounding (PWC) is widely used to measure the propagation of shear waves. Implementing PWC on most commercial ultrasound scanners is challenging because all channel (>128) data must be processed or transferred to the host computing unit in real time. Comb detection transmits multiple focused beams simultaneously and results in a reduced number of receive lines to be processed in parallel. These comb beams are scanned laterally to acquire receive lines at different lateral positions in order to obtain data over a large region-of-interest. One of the potential issues with using multiple simultaneously transmitted beams is the issue of crosstalk between the beams. Crosstalk is analyzed through simulated beam patterns, simulated B-mode images, and motion data from shear wave elastography experiments. Using a Hamming window on transmit and receive can suppress crosstalk to 1.2% root mean square error (RMSE, normalized RMSE to the peak magnitude of the reference signal) for shear wave motion signals. Four comb beams with three laterally scanned locations covers almost the entire field of view (FOV) and achieves the same frame rate as PWC with three angles. Phantom and in vivo studies demonstrate comparable motion data of comb detection to PWC in terms of motion signal quality and measured phase velocity. In addition, comb detection provides motion with lower noise and stronger signals than PWC, which is believed to be due to the advantages of transmitting focused beams rather than plane waves.