A series of cobalt and metal-free phthalocyanine ambipolar semiconductors, MPc[β/α-O(4-CF3-Ph)4] (M = Co, 2H) (1–4), are synthesized and fabricated into self-assembled microstructures. The Co[Pc(β/α-OPhCF3)4] (1 and 3) molecules formed one-dimensional (1D) nanoribbons (400–300 nm) with a larger width of 1 relative to 3, whereas the H2Pc[β/α-O(4-CF3-Ph)4] (2 and 4) molecules self-assembled into wider microbelts (5–4 μm) with 2 larger than 4, showing the effect of the M center and the substituent positions of the Pc rings on the dimensions of the microstructures. An increased crystallinity is revealed in the order of 4 < 3 < 2 < 1, resulting in an increased conductivity in the same order. Towards NO2 and NH3, both positive and negative current changes are found among the sensors 1–4, with the lowest limit of detection (LOD) as low as 3 ppb for NO2 and 420 ppb for NH3 from 1, while a positive current response to H2S is obtained only from 1 with a LOD of 100 ppb, respectively, achieving the best results for the room-temperature detection of NO2, NH3 and H2S gases based on all of the solution-processed phthalocyanine-based sensors reported so far. Accordingly, the sensor responses are dominated by both M-analyst interaction (M = Co, 2H) and conductivity among the sensors 1–4. In particular, different sensor arrays consisting of the sensor of 1 combined with one of the other three sensors of 2–4 are established. NO2, NH3 and H2S gases at ppb levels can be accurately identified by the combination of two parameters, namely current change direction and sensitivity.
1 August 2023 in IEEE Transactions on Power Electronics
Accurate identification of fault control parameters (FCPs) in the inverter-interfaced renewable energy source (IIRES) is crucial for simulating fault characteristics and designing protection. However, accurate identification can be challenging due to the correlation among FCPs. To address this issue, the correlation of parameters (COP) in the IIRES fault control process is comprehensively investigated in the s-domain and time-domain for the first time, and a multistage parameter identification method is proposed. This method partitions fault transients in different time sequences and control state spaces, allowing the COP to be decoupled and FCPs to be identified independently. The Mahalanobis distance-based objective function is used to further enhance the identification of low-sensitive parameters. Hardware-in-loop experiments and field short-circuit tests demonstrate that this method eliminates the influence of COP on parameter identification, and reliably identifies all FCPs involved during IIRES fault transients with an error of less than 9%.