1 August 2023 in IEEE Transactions on Power Electronics
Accurate identification of fault control parameters (FCPs) in the inverter-interfaced renewable energy source (IIRES) is crucial for simulating fault characteristics and designing protection. However, accurate identification can be challenging due to the correlation among FCPs. To address this issue, the correlation of parameters (COP) in the IIRES fault control process is comprehensively investigated in the s-domain and time-domain for the first time, and a multistage parameter identification method is proposed. This method partitions fault transients in different time sequences and control state spaces, allowing the COP to be decoupled and FCPs to be identified independently. The Mahalanobis distance-based objective function is used to further enhance the identification of low-sensitive parameters. Hardware-in-loop experiments and field short-circuit tests demonstrate that this method eliminates the influence of COP on parameter identification, and reliably identifies all FCPs involved during IIRES fault transients with an error of less than 9%.
8 February 2024 in IEEE Transactions on Power Delivery
In the photovoltaic DC medium voltage integration system, inter-pole short-circuit faults pose challenges to the protection in tripping faulty branches before converter blocks, consequently leading to a system-wide outage. To address this issue, active protection based on the incipient fault (IF) identification is developed to promptly trip incipient-faulty branches before the emergence of short-circuit faults. However, the minute voltage and current changes during the IF do not provide sufficient information for active protection. Given this, this research thoroughly analyzes the characteristics of the electrical and temperature fields during the IF. The finding indicates that the mutation of arc power can be effectively employed for IF identification. Therefore, an algorithm combining current and temperature measurements is proposed to accurately capture the arc's power mutation during the IF. Subsequently, an active protection criterion is established. Laboratory tests and simulation results validate the reliability of the proposed method in identifying the IF before the occurrence of short-circuit faults.
15 January 2025 in IEEE Transactions on Industrial Electronics
This study focuses on the low-voltage ride-through (LVRT) control in large-scale renewable power plants (RPPs) connected to weak grids, where grids fail to offer adequate reactive power, resulting in voltage fluctuations and necessitating additional reactive support from RPPs. However, in weak grids, the impact of system-side responses on LVRT control—especially transformer connections (TCs)—becomes increasingly significant. The existing research overlooks this factor as its negligible effects in strong grid scenarios. However, in weak grids, this oversight becomes critical, as it can lead to voltage overruns at certain voltage levels, posing risks to system safety. Given this, a system-level LVRT control is proposed, focusing on safety constraints from system-side responses. This work introduces a novel voltage boundary vector trajectory model that captures the geometric relationships of the system-side response, allowing for a more accurate determination of voltage controllable boundaries. To compute optimal commands in the constructed boundaries, a discrete and clustering matrix-based calculation algorithm is proposed. Based on the hardware-in-loop experimental platform, comparisons are made with both the latest literature and widely adopted engineering practices. It is proven that voltage overruns can easily occur with the short circuit ratio (SCR) of less than 3, which can be up to 14%. This study effectively solves this security problem and simultaneously increases reactive power support by at least 30% when the voltage sag is not below 0.3 p.u.
9 October 2025 in IEEE Transactions on Industrial Electronics
In a modular multilevel converter-based multiterminal high-voltage direct current (MMC-HVdc) system, unbalanced active power (UAP) between converters is easily induced after ac/dc faults, resulting in severe dc transient overvoltage. To solve this problem, a postfault dc transient overvoltage control is proposed. The generation mechanism of UAP among multiterminal MMCs is analyzed, and the coupling model linking UAP to dc overvoltage is established, revealing a positive correlation between the peak voltage and UAP amplitude. Within the MMC region connected to the wind farm (WF), the proposed method achieves optimal allocation of UAP to suppress the overvoltage peak by dynamically coordinating multiple power units in accordance with the time sequence. Specifically, the submodule capacitor voltage boosting capability in the MMC serves as temporary energy storage, and UAP is redistributed between the WF and the DBR based on the energy equal area criterion. The real-time digital tests show that the proposed method reduces the peak transient overvoltage by over 9.1%, stabilizing at 1.0 p.u. and exhibits superior voltage control capability compared to other methods. Additionally, it minimizes reliance on the DBR, reducing DBR capacity and head dissipation by more than 25% and 25.58%, respectively, thereby enhancing the safety of the MMC-HVdc system.
30 April 2026 in IEEE Transactions on Sustainable Energy
Large-scale renewable power plants (RPPs) should coordinate numerous differentiated inverter-based resources (IBRs) to provide reliable voltage support under low-voltage ride-through (LVRT). Yet the reactive-power controllable boundary (RCB) of multiple IBRs under asymmetric LVRT remains insufficiently explored, limiting support capability and risking local over-voltage. This study develops a unified RCB model that considers the impacts of interactive coupling, phase-locking deviation, and voltage propagation. Then, four tight constraints are derived from RCB vector trajectories on the complex domain plane to shrink the original RCB equations, yielding a linear and decoupled minimum RCB intersection under various fault conditions. The minimum RCB can regulate the conservative distribution of sequence voltage boundaries allowed for each bus based on the RPP's pre-event state. During LVRT, a coordinated voltage support strategy is proposed to distributed adjust reactive outputs of multiple IBRs following an optimal trajectory in the pre-given RCB, which maximizes voltage support capability. The hardware-in-the-loop experiment referred to an actual large-scale RPP project shows that the proposed strategy eliminates local over-voltage risks observed in existing strategies (up to 17.3%) and improves the faulted-phase voltage support capability by 17.48% on average across various fault conditions.