Yunus Msayib

Yunus Msayib

Auto-generated profile, based on publicly available information

Yunus Msayib

Radiology Department, Stanford University, California, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 April 2017 in Journal of Medical Systems
Verified
Journal Article
Closed access
PDF file
YMYunus Msayib
Yunus Msayib
PGPatrick Gaydecki
Patrick Gaydecki
MCMichael Callaghan
Michael Callaghan
NDNicola Dale
Nicola Dale
SISheheera Ismail
Sheheera Ismail

28 December 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JPJoon Sik Park
Joon Sik Park
EMEppu Manninen
Eppu Manninen
YYYihong Yang
Yihong Yang
DBDan Benjamini
Dan Benjamini
Purpose: To develop a robust and efficient multidimensional MRI (MD‐MRI) data processing framework for accurately estimating joint frequency‐dependent diffusion‐relaxation distributions, while overcoming computational limitations and noise instability inherent to Monte Carlo (MC) inversion. Methods: We introduced an Informed Dictionary‐guided Monte Carlo (ID‐MC) strategy that incorporates data‐driven dictionary matching into the inversion process, followed by targeted local mutation refinement to enhance flexibility and reduce overfitting. This hybrid approach aims to improve the stability, accuracy, and reproducibility of MD‐MRI parameter estimation. We evaluated ID‐MC through in silico simulations across a range of signal‐to‐noise ratios and in vivo test–retest experiments in the human brain. Reproducibility was assessed using intraclass correlation coefficients (ICC) and within‐subject variability, allowing rigorous comparison with MC. Results: In simulations, the ID‐MC approach consistently achieved lower fitting errors and higher estimation accuracy across a wide range of noise levels, demonstrating its ability to balance local flexibility and global biological plausibility. Compared to MC inversion, ID‐MC also reduced computation time by approximately 69%, highlighting its potential for time‐efficient large‐scale applications. In in vivo test–retest analyses, ID‐MC substantially improved reproducibility, doubling the number of MD‐MRI parameters with ICC greater than 0.75 relative to MC. Notably, diffusion frequency‐dependent parameters, previously poorly reproducible with MC, showed up to 146% higher ICC with ID‐MC. Conclusion: By integrating data‐driven dictionary matching with targeted mutation refinement, ID‐MC improves the robustness, reproducibility, and computational efficiency of MD‐MRI inversion, supporting studies that require highly sensitive detection of subtle brain microstructural changes.

7 March 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
YMYunus Msayib
Yunus Msayib
GHGeorge W. J. Harston
George W. J. Harston
KRKevin J. Ray
Kevin J. Ray
JLJames R. Larkin
James R. Larkin
BSBrad A. Sutherland
Brad A. Sutherland
MCMichael A. Chappell
Michael A. Chappell
Purpose: In chemical exchange saturation transfer imaging, saturation effects between 2 to 5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4‐pool Bloch–McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3‐pool model.Methods: MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch–McConnell models (4 pools, and a 3‐pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naïve mouse brain.Results: The 4‐pool measure of NOEs exhibited a different association with tissue outcome compared to 3‐pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4‐pool measure was elevated in patient white matter () and in animals (). In the naïve brain pH phantoms, significant positive correlation between the NOE and pH was observed.Conclusion: Associations of NOEs with tissue pathology were found using the 4‐pool metric that were not observed using the 3‐pool approximation. The 4‐pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.

5 August 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
JZJunru Zhong
Junru Zhong
CHChaoxing Huang
Chaoxing Huang
ZYZiqiang Yu
Ziqiang Yu
FXFan Xiao
Fan Xiao
TBThierry Blu
Thierry Blu
WCWeitian Chen
Weitian Chen
Purpose: To propose and evaluate an accelerated quantification method that combines ‐weighted fast spin echo (FSE) images and proton density (PD)‐weighted anatomical FSE images, leveraging deep learning models for mapping. The goal is to reduce scan time and facilitate integration into routine clinical workflows for osteoarthritis (OA) assessment.Methods: This retrospective study utilized MRI data from 40 participants (30 OA patients and 10 healthy volunteers). A volume of PD‐weighted anatomical FSE images and a volume of ‐weighted images acquired at a non‐zero spin‐lock time were used as input to train deep learning models, including a 2D U‐Net and a multi‐layer perceptron (MLP). maps generated by these models were compared with ground truth maps derived from a traditional non‐linear least squares (NLLS) fitting method using four ‐weighted images. Evaluation metrics included mean absolute error (MAE), mean absolute percentage error (MAPE), regional error (RE), and regional percentage error (RPE).Results: The best‐performed deep learning models achieved RPEs below 5% across all evaluated scenarios. This performance was consistent even in reduced acquisition settings that included only one PD‐weighted image and one ‐weighted image, where NLLS methods cannot be applied. Furthermore, the results were comparable to those obtained with NLLS when longer acquisitions with four ‐weighted images were used.Conclusion: The proposed approach enables efficient mapping using PD‐weighted anatomical images, reducing scan time while maintaining clinical standards. This method has the potential to facilitate the integration of quantitative MRI techniques into routine clinical practice, benefiting OA diagnosis and monitoring.

10 July 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
NWNan Wang
Nan Wang
DADaniel Abraham
Daniel Abraham
ZSZachary Shah
Zachary Shah
YLYimeng Lin
Yimeng Lin
XCXiaozhi Cao
Xiaozhi Cao
KSKawin Setsompop
Kawin Setsompop
Purpose: To develop a Field-Correcting GRAPPA (FCG) technique to correct the spatiotemporal-varying phase errors in EPI caused by eddy currents. Methods: The fast-changing gradient in EPI causes strong eddy current effects and associated spatiotemporal-varying phase errors, producing significant image artifacts. The use of higher gradient amplitude, slew rate, and ramp sampling factor for faster imaging exacerbates this problem. In this work, FCG was developed to address this challenge by using a multi-layer perceptron (MLP) to provide a compact representation of a family of GRAPPA-like kernels that correct the spatiotemporal-varying phase errors in the data. A dedicated calibration pipeline was designed to acquire high-quality source and target data for MLP training in both slice-by-slice and simultaneous multi-slice (SMS) acquisitions. To validate FCG’s assumptions and performance, a field camera was used to provide ground-truth measurement of phase patterns. The performance of FCG was further validated on phantom and in vivo experiments using demanding EPI trajectories across multiple 3T and 7T systems. Results: Field camera measurements revealed strong spatiotemporal phase variations along the k x direction that repeat along ky during EPI readouts. The experiments on high-performance systems across 3T and 7T demonstrate that FCG can provide superior correction for the artifacts induced by spatiotemporal-varying phase errors compared with existing approaches. Conclusion: FCG is an effective and robust method for correcting spatiotemporal phase errors in EPI, enabling improved image quality on high-performance systems.

20 August 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
YMY. Msayib
Y. Msayib
MCM. Craig
M. Craig
MSM. A. Simard
M. A. Simard
JLJ. R. Larkin
J. R. Larkin
DSD. D. Shin
D. D. Shin
MCM. A. Chappell
M. A. Chappell
Purpose: Multi‐phase PCASL has been proposed as a means to achieve accurate perfusion quantification that is robust to imperfect shim in the labeling plane. However, there exists a bias in the estimation process that is a function of noise in the data. In this work, this bias is characterized and then addressed in animal and human data.Methods: The proposed algorithm to overcome bias uses the initial biased voxel‐wise estimate of phase tracking error to cluster regions with different off‐resonance phase shifts, from which a high‐SNR estimate of regional phase offset is derived. Simulations were used to predict the bias expected at typical SNR. Multi‐phase PCASL in 3 rat strains (n = 21) at 9.4 T was considered, along with 20 human subjects previously imaged using ASL at 3 T. The algorithm was extended to include estimation of arterial blood flow velocity.Results: Based on simulations, a perfusion estimation bias of 6‐8% was expected using 8‐phase data at typical SNR. This bias was eliminated when a high‐precision estimate of phase error was available. In the preclinical data, the bias‐corrected measure of perfusion (107 ± 14 mL/100g/min) was lower than the standard analysis (116 ± 14 mL/100g/min), corresponding to a mean observed bias across strains of 8.0%. In the human data, bias correction resulted in a 15% decrease in the estimate of perfusion.Conclusions: Using a retrospective algorithmic approach, it was possible to exploit common information found in multiple voxels within a whole region of the brain, offering superior SNR and thus overcoming the bias in perfusion quantification from multi‐phase PCASL.