Achintya Haldar

Achintya Haldar

Auto-generated profile, based on publicly available information

Achintya Haldar

University of Arizona

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2017 in Sensors
Verified
Journal Article
Open access
PDF file
QTQuang Huy Tran
Quang Huy Tran
DHDongyeob Han
Dongyeob Han
CKChoonghyun Kang
Choonghyun Kang
AHAchintya Haldar
Achintya Haldar
Jungwon HuhJungwon Huh
Jungwon Huh
Active thermal imaging is an effective nondestructive technique in the structural health monitoring field, especially for concrete structures not exposed directly to the sun. However, the impact of meteorological factors on the testing results is considerable and should be studied in detail. In this study, the impulse thermography technique with halogen lamps heat sources is used to detect defects in concrete structural components that are not exposed directly to sunlight and not significantly affected by the wind, such as interior bridge box-girders and buildings. To consider the effect of environment, ambient temperature and relative humidity, these factors are investigated in twelve cases of testing on a concrete slab in the laboratory, to minimize the influence of wind. The results showed that the absolute contrast between the defective and sound areas becomes more apparent with an increase of ambient temperature, and it increases at a faster rate with large and shallow delaminations than small and deep delaminations. In addition, the absolute contrast of delamination near the surface might be greater under a highly humid atmosphere. This study indicated that the results obtained from the active thermography technique will be more apparent if the inspection is conducted on a day with high ambient temperature and humidity.

18 July 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Jungwon HuhJungwon Huh
Jungwon Huh
QTQuang Huy Tran
Quang Huy Tran
AHAchintya Haldar
Achintya Haldar
IPInnjoon Park
Innjoon Park
JAJin-Hee Ahn
Jin-Hee Ahn
Tunnels, culverts, and subway stations are the main parts of an integrated infrastructure system. Most of them are constructed by the cut-and-cover method at shallow depths (mainly lower than 30 m) of soil deposits, where large-scale seismic ground deformation can occur with lower stiffness and strength of the soil. Therefore, the transverse racking deformation (one of the major seismic ground deformation) due to soil shear deformations should be included in the seismic design of underground structures using cost- and time-efficient methods that can achieve robustness of design and are easily understood by engineers. This paper aims to develop a simplified but comprehensive approach relating to vulnerability assessment in the form of fragility curves on a shallow two-story reinforced concrete underground box structure constructed in a highly-weathered soil. In addition, a comparison of the results of earthquakes per peak ground acceleration (PGA) is conducted to determine the effective and appropriate number for cost- and time-benefit analysis. The ground response acceleration method for buried structures (GRAMBS) is used to analyze the behavior of the structure subjected to transverse seismic loading under quasi-static conditions. Furthermore, the damage states that indicate the exceedance level of the structural strength capacity are described by the results of nonlinear static analyses (or so-called pushover analyses). The Latin hypercube sampling technique is employed to consider the uncertainties associated with the material properties and concrete cover owing to the variation in construction conditions. Finally, a large number of artificial ground shakings satisfying the design spectrum are generated in order to develop the seismic fragility curves based on the defined damage states. It is worth noting that the number of ground motions per PGA, which is equal to or larger than 20, is a reasonable value to perform a structural analysis that produces satisfactory fragility curves.

4 June 2015 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
AAAbdullah Al-Hussein
Abdullah Al-Hussein
AHAchintya Haldar
Achintya Haldar

1 June 2005 in Journal of Structural Engineering
Verified
Journal Article
Closed access
HKHasan Katkhuda
Hasan Katkhuda
RMRene Martinez
Rene Martinez
AHAchintya Haldar
Achintya Haldar
A finite-element-based procedure is proposed to identify defects in existing structures and evaluate their extent at the local element level for the purpose of health assessment. The procedure is a time-domain system identification technique where input excitation is not required to identify a structure. It estimates the dynamic properties of a structure in terms of stiffness and damping at the element level in a finite-element representation. The method can be used to precisely locate a defective spot in an element. Although input excitation information is not required, examples are used to show that the algorithm is robust enough to identify a structure excited by different types of loading. Structures can be excited simultaneously by multiple loadings, and the response information can be noise-free or noise-contaminated. Defects can be small or relatively large. In all cases, the algorithm identified the structures correctly. The error in the identification is considerably smaller than that of other av...

13 September 2007 in Structural Control and Health Monitoring
Verified
Journal Article
Closed access
PDF file
HKHasan Katkhuda
Hasan Katkhuda
AHAchintya Haldar
Achintya Haldar
A novel structural health assessment method is proposed for detecting defects at the element level using only minimum measured response information considering imperfect mathematical model representing the structure, various sources of uncertainty in the mathematical model, and uncertainty in the measured response information. It is a linear time domain finite element-based system identification procedure capable of detecting defects at the local element level using only limited response measurements and without using any information on the exciting dynamic forces. The technique is a combination of the modified iterative least-squares technique with unknown input excitation (MILS-UI) proposed earlier by the research team at the University of Arizona and the extended Kalman filter with a weighted global iteration (EKF-WGI) procedures to address different sources of uncertainty in the problem. The authors denote the new method as GILS-EKF-UI. To implement the concept, a two-stage substructure approach is used. In the first stage, a substructure is selected that satisfies all the requirements for the MILS-UI procedure. This provides information on the initial state vector and the input excitation required to implement any EKF-based procedure. In the second stage, the EKF-WGI is applied to identify the whole structure. This way the whole structure, defect free or defective, can be identified with limited response measurements in the presence of uncertainty and without using excitation information. The theoretical concept behind this novel method is presented in this paper. Copyright © 2007 John Wiley & Sons, Ltd.

1 July 1995 in Journal of Structural Engineering
Verified
Journal Article
Closed access
LGLiwei Gao
Liwei Gao
AHAchintya Haldar
Achintya Haldar
An efficient nonlinear stochastic finite-element method is proposed for the design of frame structures, specifically applicable to steel structures. The assumed stress-based finite-element method is used to compute nonlinear structural responses and the corresponding response gradients. Nonlinearities due to geometry, material, and partially restrained (PR) connections are considered in the algorithm. Elastoplastic material behavior is considered and the PR connections are modeled by the four-parameter Richard model. The material properties, geometry, connections parameters, and external loads are considered to be random variables. Both the strength and serviceability limit states are considered. The efficiency, robustness, desirability, and application potential of the method are demonstrated by two examples. Several observations with design implications can be made from these examples. Frames designed for strength may not be safe when serviceability is considered. The presence of PR connections makes th...