23 September 2024 in IEEE Access
Integrating renewable energy resources into the existing generation capacity can handle the additional load resulting from the EV charging system, even when the majority of the EVs are charged during off-peak hours. This paper comprehensively analyzes EV charging methods with a particular focus on both grid-based direct charging and the utilization of renewable energy sources. However, the most practical approach for EV charging is through large-scale grid-based renewable energy stations. This study outlines the significant challenges facing the application of EV chargers. Overcoming these challenges is vital for the widespread adoption of new technologies such asWireless power transfer charging systems in the EV sector. Wireless charging technology still faces several issues, such as energy loss during transmission, alignment between the coils, and quick and safe power delivery. One of the significant challenges facing wireless chargers is the need to optimize efficiency while ensuring convenient and reliable charging as outlined in this study. Different wireless charger configurations are presented for stationary EV charging systems by incorporating photovoltaic systems into charging stations and supervisory bases. The application of series-series wireless charger system as an emerging technology for EV chargers is analyzed and simulated as a recommended solution for EV wireless chargers. The system overall efficiency is approximately 98%. The charging system can operate reliably by mitigating the effects of load and grid disturbances.
9 July 2018 in IEEE Transactions on Power Electronics
In this paper, a practical online open-switch fault detection method is presented. The proposed open-switch fault detection method is used to detect the open-circuited fault switch in the parallel inverters system. This method can relieve the severe effects of the over-current stress, to avoid the secondary fault to the electrical components in the parallel inverters system. This method is based on the detection of the resulting zero-sequence current, under the fault conditions. The proposed algorithm is activated by detecting the zero-sequence current between the parallel units, under the open-switch fault conditions. The sign of the resulting zero-sequence current is related to the upper or the lower open-switch fault case. The faulty phase identification relies on the analysis and the investigation of only the current measurements information of the faulty inverter. This method can get rid of the effects of the load, to obtain a reliable identification. The effectiveness of the proposed open-switch fault detection algorithm, is theoretically analyzed and validated by the simulations and the experiments.
6 May 2023 in Sustainable Energy, Grids and Networks
25 August 2023 in IEEE Transactions on Electromagnetic Compatibility
In regions having high activity of lightning flashes, it is important to investigate the lightning-induced electromagnetic (EM) transients affecting buried cables, particularly if such buried conductors are extending close to grounded towers, such as wind towers. In this article, the impact of the grounded wind tower, ground conductivity and permittivity, depth of the cable, and its position from the return stroke on the lightning-induced EM fields on the cable sheath are investigated. In addition, the lightning-induced EM fields on the cable sheath are also calculated with the presence of bare-underground wire above the cable as a protection against lightning strikes. The 3-D finite difference time domain method with nonuniform grid technique is implemented for this study. From the results, it is shown that the presence of wind tower increases the magnitude of lightning-induced EM fields on the cable sheath, particularly for close distances between cable and tower. Moreover, the impact of soil permittivity on lightning-induced EM surges becomes significant for low soil conductivity. Also, the impact of cable depth becomes more significant for higher soil conductivity. Furthermore, the bare-underground wire reduces the magnitude of lightning-induced electric field.
17 May 2022 in IEEE Access
Parallel operation of multiple AC/DC inverters is favorable in hybrid AC/DC microgrids to avert consecutive conversion stages and increase the system’s efficacy. Yet, several emerging technical challenges impede the expansion of such layout such as the circulating currents, sensitiveness to the input voltage disturbances, load variations and complexity of the control structures caused by using several required measurements. This paper proposes a one-loop sensorless controller which is based on the flatness technique for a non-isolated power supply consisting of n-parallel inverters. The proposed control scheme primarily relies on employing a nonlinear online observer to estimate the line inductor currents and the dc link voltage via information from the input voltage, output voltage, and load conditions to avoid using excessive sensors. In this way, the system reliability is improved by reducing burdens of the communication delays and/or the failures, signal noise, thus the system is featured by simple control. Besides, the system entire losses are modeled by equivalent voltage sources and one current source which implicitly represent all types of the losses by using an online nonlinear estimator for the control purposes. The proposed controller not only has high dynamic performance, wide-bandwidth, low voltage THD but also robust to the abrupt variations in the load and the input voltage. To validate the applicability of the proposed control method and the observer, both simulations and experimental investigations are performed for two paralleled three-phase inverters setup. The obtained results assure the effectiveness of the proposed control method in regulating the output voltage of the parallel DC/AC inverters with fewer number of the sensors against the fluctuations of the input dc voltage and the load perturbations.
21 January 2025 in Electric Power Systems Research