Sankar Ram Thekkethil

Sankar Ram Thekkethil

Auto-generated profile, based on publicly available information

Sankar Ram Thekkethil

Inter-University Accelerator Centre

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2016 in Procedia Technology
Verified
Journal Article
Open access
STS.R. Thekkethil
S.R. Thekkethil
KRK.E. Reby Roy
K.E. Reby Roy
RTR.J. Thomas
R.J. Thomas
HNH. Neumann
H. Neumann
RRR. Ramalingam
R. Ramalingam
In this work, a mathematical model is presented for a newly developed cryogenic flow meter which is based on fibre Bragg grating (FBG) principle. The principle of operation is to use the viscous drag force induced by a flowing fluid on an optical fibre placed transverse to the flow. An optical fibre will have a 5mm long grating element inscribed in it and will be placed so that the sensor is at the centre of the pipe. The fibre will act as the bluff body, while the FBG sensor will pick up the bending strain induced in the fibre due to the drag force. The amount of bending strain which can be measured as a shift in Bragg wavelength can be calibrated to provide the mass flow rate. Here a mathematical model is being presented to predict the operation of the sensor and to calculate the sensor characteristics so that the sensor design can be optimised. The sensor exhibits an exponential relationship between sensitivity and mass flow rate. It is also seen that the sensitivity depends greatly on the fluid properties such as density and viscosity

1 November 2015
Verified
Conference Paper
Closed access
STS. R. Thekkethil
S. R. Thekkethil
VVV. Narayanan Venkatesan
V. Narayanan Venkatesan
HNH. Neumann
H. Neumann
RRR. Ramalingam
R. Ramalingam
This paper describes a novel technique to measure cryogenic fluid flow rate using fiber Bragg grating (FBG) sensors. The proposed design utilizes the drag force caused by fluid flow on the FBG sensor. The strain thus induced in the sensor will cause a Bragg wavelength shift, which can be utilized to estimate the flow rate. Theoretical calculations are done using mathematical models and the design is found to be feasible for a wide range of flow rates and cryogenic temperatures. Calibration experiments are performed for Helium at ambient conditions and the results obtained are regressed to obtain its calibration equation. The sensor shows an overall sensitivity of 20 pm/(g/s) in the range of operation between 0 and 2 g/s and 50 pm/(g/s) in the range of 2 to 5 g/s.

19 November 2022 in Physica C: Superconductivity and its Applications
Verified
Journal Article
Closed access
STSankar Ram Thekkethil
Sankar Ram Thekkethil
SKSoumen Kar
Soumen Kar
VRVikas Rastogi
Vikas Rastogi

28 February 2017 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
STS. R. Thekkethil
S. R. Thekkethil
RTR. J. Thomas
R. J. Thomas
HNH. Neumann
H. Neumann
RRRajinikumar Ramalingam
Rajinikumar Ramalingam
Flow measurement and control of cryogens is one of the major requirements of systems such as superconductor magnets for fusion reactors, MRI magnets etc. They can act as an early diagnostic tool for detection of any faults and ensure correct distribution of cooling load while also accessing thermal performance of the devices. Fibre Bragg Grating (FBG) sensors provide compact and accurate measurement systems which have added advantages such as immunity towards electrical and magnetic interference, low attenuation losses and remote sensing. This paper summarizes the initial experimental investigations and calibration of a novel FBG based mass flow meter. This design utilizes the viscous drag due to the flow to induce a bending strain on the fibre. The strain experienced by the fibre will be proportional to the flowrate and can be measured in terms of Bragg wavelength shift. The flowmeter is initially tested at atmospheric conditions using helium. The results are summarized and the performance parameters of the sensor are estimated. The results were also compared to a numerical model and further results for liquid helium is also reported. An overall sensitivity of 29 pm.(g.s-1)-1 was obtained for a helium flow, with a resolution of 0.2 g.s-1. A hysteresis error of 8 pm was also observed during load-unload cycles. The sensor is suitable for further tests using cryogens.

7 July 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
VSVijay Soni
Vijay Soni
NSNavneet Suman
Navneet Suman
STSankar Ram Thekkethil
Sankar Ram Thekkethil
ANAjit Nandawadekar
Ajit Nandawadekar
RKRajesh Kumar
Rajesh Kumar
SKSoumen Kar
Soumen Kar
An actively shielded 1.5 T superconducting MRI magnet is designed for a whole-body clinical scanner. During a quench, its fast-decaying field induces a strong eddy current in all the conductive parts of the cryostat. The eddy current together with the decaying magnetic field generates Lorentz force, which generates stress and deformation in the bobbin structure, thermal shield, and other conductive parts of the cryostat. In this article, we report the analysis of the eddy current distribution induced in the bobbin structure and thermal shield made of various alloys of the MRI magnet system using a finite element analysis program. The net forces on each part of the bobbin structure and the thermal shield and the associated stress distribution, the deformation are analyzed in detail using OPERA-3D software. The eddy-current-induced effects on a few metallic alloys are compared for generating design inputs for the bobbin structure and the thermal shield of the MRI magnet system. We also report the transient behavior of the eddy current in correlation with the decaying current during a quench.

1 January 2018 in Indian Journal of Cryogenics
Verified
Journal Article
Closed access
PDF file
STSankar Ram Thekkethil
Sankar Ram Thekkethil
SKSoumen Kar
Soumen Kar
NSNavneet Suman
Navneet Suman
MKMukesh Kumar
Mukesh Kumar
VSVijay Soni
Vijay Soni
TDTripti Sekhar Datta
Tripti Sekhar Datta
The paper presents the analysis of stresses due to winding tension in a 1.5 T MRI magnet with a clear bore of ~1 m and an outer diameter of ~1.8 m. The magnet has four pairs of symmetric coils arranged over a length of ~1.5 m. The stringent requirement of field homogeneity makes it critical to design a structurally stable magnet system. It is essential to evaluate the 3-dimensional stresses that would be generated in the magnet during winding, cool down and operation. The bobbin structure also has to be designed so as to reduce the relative movements of theeight superconducting coils, which otherwise can adversely affect the field homogeneity at the Field of View (FOV). The bobbin will be made of aluminium 5083 alloy, while the magnet winding will be a composite structure which consists of NbTi, copper and polyester insulation. The paper discusses the stress distribution over the aluminium bobbin and the coil caused due to winding tension applied during magnet winding. The article also discusses the element death and birth method in FEA to accurately simulate the winding process.