Navneet Suman

Navneet Suman

Auto-generated profile, based on publicly available information

Navneet Suman

Inter-University Accelerator Centre

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
VSVijay Soni
Vijay Soni
NSNavneet Suman
Navneet Suman
STSankar Ram Thekkethil
Sankar Ram Thekkethil
ANAjit Nandawadekar
Ajit Nandawadekar
RKRajesh Kumar
Rajesh Kumar
SKSoumen Kar
Soumen Kar
An actively shielded 1.5 T superconducting MRI magnet is designed for a whole-body clinical scanner. During a quench, its fast-decaying field induces a strong eddy current in all the conductive parts of the cryostat. The eddy current together with the decaying magnetic field generates Lorentz force, which generates stress and deformation in the bobbin structure, thermal shield, and other conductive parts of the cryostat. In this article, we report the analysis of the eddy current distribution induced in the bobbin structure and thermal shield made of various alloys of the MRI magnet system using a finite element analysis program. The net forces on each part of the bobbin structure and the thermal shield and the associated stress distribution, the deformation are analyzed in detail using OPERA-3D software. The eddy-current-induced effects on a few metallic alloys are compared for generating design inputs for the bobbin structure and the thermal shield of the MRI magnet system. We also report the transient behavior of the eddy current in correlation with the decaying current during a quench.

10 June 2022 in Journal of Pressure Vessel Technology
Verified
Journal Article
Closed access
PDF file
NSNavneet Kumar Suman
Navneet Kumar Suman
ASArshad Noor Siddiquee
Arshad Noor Siddiquee
SKSoumen Kar
Soumen Kar
A whole-body 1.5 T superconducting MRI magnet is operated in 4.2 K inside a zero-boil-off helium cryogenic vessel, i.e., cryostat. The cryostat has horizontal bore of 850 mm used as the patient bore. The cryostat houses the 1.5 T superconducting magnet in a coaxial position maintaining a high degree of alignment along with the gradient coil, the birdcage RF coil necessary for any MRI scanner. A set of support link having low thermal conductivity and higher mechanical strength would provide structural support to the cold mass at 4.2 K, which includes the superconducting magnet, helium vessel. A two stage 4.2 K G-M cryocooler is used to recondense helium to achieve a “zero boil-off” condition. The helium vessel and the vacuum vessel of the cryostat experience stresses during the normal operation, transportation etc. The ASME B&PV Code and the Finite Element Analysis has been used for the engineering design and stress analysis of cryostat. The modal analysis of the cryostat has been done during the transportation of the cryostat. The seismic behavior of the cryostat has also been analyzed extensively for a 1.5 T MRI cryostat.

1 January 2018 in Indian Journal of Cryogenics
Verified
Journal Article
Closed access
PDF file
NSNavneet Suman
Navneet Suman
SKSoumen Kar
Soumen Kar
MKMukesh Kumar
Mukesh Kumar
STSankar Ram Thekkethi
Sankar Ram Thekkethi
VSVijay Soni
Vijay Soni
TDTripti Sekhar Datta
Tripti Sekhar Datta
Support system is one of the most critical components of any zero boil off MRI cryostat. We have designed and analysed twelve self-centring support structures for the warm bore horizontal cryostat for testing of 1.5T superconducting MRI magnet. The design has been optimized to have maximum tensile strength, minimum resonant frequency, heat load, maximum pretension force and with allowable accelerations. The dimensional constraints as well as requirements for structural stability has been established. The s-glass support straps with intermediate thermal intercepts at 60–80K and has been designed to suspend the five tons cold mass during assembly, shipment and normal operation of the MRI magnet. This paper briefly discusses the static and dynamic stress simulation of cryogenic support link of the MRI cryostat using ANSYS.

1 January 2020 in Indian Journal of Cryogenics
Verified
Journal Article
Closed access
PDF file
NSNavneet Suman
Navneet Suman
ASArshad Noor Siddiquee
Arshad Noor Siddiquee
STSankar Ram Thekkethil
Sankar Ram Thekkethil
VSVijay Soni
Vijay Soni
ANAjit Nandwadekar
Ajit Nandwadekar
SKSoumen Kar
Soumen Kar
Present-day whole-body MRI scanners are of “zero boil-off" type which hardly need liquid helium refill. To realize this requirement, the cryostat housing of the superconducting magnet system and many several sub-systems need highly innovative design. This includes the state-of-art design of the support system for the large cold mass (~ 4 tons) meeting the stringent requirements of minimum heat input to the LHe-bath, possessing high strength to take care of the high thermo-mechanical stresses, heavy load, transportation and keeping the magnet center unaffected through self-regulation. In this paper, we report coupled thermomechanical and modal analysis of the support system, performed using ANSYS to study temperature deformation and stress in the support assembly. The design includes mechanical strength, minimum resonant frequency, heat load calculations, maximum pretension force and allowable accelerations for the maximum pre-tension. The design incorporates carbon- glass (HS carbon) rods supporting nearly four tons cold mass during assembly, shipment and the normal operation of the MRI magnet.

1 January 2016 in Indian Journal of Cryogenics
Verified
Journal Article
Closed access
PDF file
NSNavneet Suman
Navneet Suman
VSVijay Soni
Vijay Soni
SKSoumen Kar
Soumen Kar
ACAnup Choudhury
Anup Choudhury
SSSunil Kumar Sarangi
Sunil Kumar Sarangi
TDTripti Sekhar Datta
Tripti Sekhar Datta
Two stage GM cryocooler is one of the major components for development of any conduction cooled superconducting magnet system. Recently, IUAC New Delhi has developed a 6T conduction cooled NbTi magnet system using a two stage GM cryocooler (Sumitomo SRDK - 415D) of refrigeration capacity of 1.5W at 4.2K and 40W at 50K. The commercially available typical load map of the SRDK-415D cryocooler shows few ‘discrete’ points. The commercial load map most of the time is not sufficient to analyse the thermal characteristics of the NbTi magnet system. This paper briefly discusses the full scaled practical load map for the SRDK - 415D cryocooler generated using a test rig. This paper also gives the detail of the continuous load curves for both the stages of the cryocooler. Details of the test setup, measurement methodology to generate the practical load curves, parameters responsible for temperature fluctuation, have been described.

1 January 2016 in Indian Journal of Cryogenics
Verified
Journal Article
Closed access
PDF file
VSVijay Soni
Vijay Soni
NSNavneet Suman
Navneet Suman
SSSunil Kumar Sarangi
Sunil Kumar Sarangi
TDTripti Sekhar Datta
Tripti Sekhar Datta
SKSoumen Kar
Soumen Kar
Hybrid current lead is one of the important parts for the development of cryogen free superconducting magnet system. The thermal stability of the NbTi magnet is greatly dependent on the performance of the hybrid current lead. Hybrid current lead, which is a combination of the metallic (copper) lead and HTS lead, has some inter-lead joints which need to be electrically insulating and thermally conducting with the different stages of the cryocooler. A thermal anchoring block of oxygen-free high-conductivity (OFHC) copper is developed for inter-lead thermal joint. A detailed experimental study is carried out using Kapton and Aluminium nitride (AlN) as interlayer insulation material in the thermal anchoring block. The thermal resistance of the interface for 19 mm2 contact surface area, is found to be ˜7 K/W and ˜15 K/W for Kapton and Aluminium nitride (AlN) respectively at 4.2 K temperature range and ˜0.6 K/W (nearly similar) for both Kapton and Aluminium nitride (AlN) at 40 K temperature range. Dependency of the thermal impedance on the contact surface area is also discussed in details.