Ajit Nandawadekar

Ajit Nandawadekar

Auto-generated profile, based on publicly available information

Ajit Nandawadekar

Department of Electrical Engineering, Delhi Technological University, Delhi, India

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
VSVijay Soni
Vijay Soni
NSNavneet Suman
Navneet Suman
STSankar Ram Thekkethil
Sankar Ram Thekkethil
ANAjit Nandawadekar
Ajit Nandawadekar
RKRajesh Kumar
Rajesh Kumar
SKSoumen Kar
Soumen Kar
An actively shielded 1.5 T superconducting MRI magnet is designed for a whole-body clinical scanner. During a quench, its fast-decaying field induces a strong eddy current in all the conductive parts of the cryostat. The eddy current together with the decaying magnetic field generates Lorentz force, which generates stress and deformation in the bobbin structure, thermal shield, and other conductive parts of the cryostat. In this article, we report the analysis of the eddy current distribution induced in the bobbin structure and thermal shield made of various alloys of the MRI magnet system using a finite element analysis program. The net forces on each part of the bobbin structure and the thermal shield and the associated stress distribution, the deformation are analyzed in detail using OPERA-3D software. The eddy-current-induced effects on a few metallic alloys are compared for generating design inputs for the bobbin structure and the thermal shield of the MRI magnet system. We also report the transient behavior of the eddy current in correlation with the decaying current during a quench.

30 April 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ANAjit Nandawadekar
Ajit Nandawadekar
VSV. Soni
V. Soni
NSN. Suman
N. Suman
STSankar Ram T
Sankar Ram T
RKR. Kumar
R. Kumar
SKSoumen Kar
Soumen Kar
A prototype persistent current switch is developed for an actively shielded whole-body 1.5 T MRI magnet having an operating current of ~ 500A. The switch is developed using a six-strand CuNi-NbTi conductor. The total length of the conductor used in the PCS is ~ 40 m using a bifilar winding technique having a room temperature resistance of 15 and an inductance of 6.6 H. Two numbers of thermo-foil heaters having a resistance of 90 each are placed between the layers of the winding pack of the switch. The wet-winding technique is followed for the switch using a cryogenic grade epoxy. The characteristics of the switch are performed using a 4 K test rig for its applicability in the 1.5 T MRI magnet. The normal resistance of the switch is measured to be 12.5 at 15 K which is 15% less than the estimated value. The total energy loss onto the switch is estimated to be 0.24% of the ramping energy of the magnet at 6 V charging voltage. The thermal switching profile of the switch is studied and correlated with the total energy loss.

13 May 2022 in Journal of The Institution of Engineers (India): Series B
Verified
Journal Article
Closed access
PDF file
ANAjit Nandawadekar
Ajit Nandawadekar
MRM. R. Rashmi
M. R. Rashmi
KNK. K. Nipin
K. K. Nipin

1 December 2023 in Journal of Power Electronics
Verified
Journal Article
Closed access
PDF file
ANAjit Nandawadekar
Ajit Nandawadekar
MSMukhtiar Singh
Mukhtiar Singh
SKSoumen Kar
Soumen Kar

1 October 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
ANAjit Nandawadekar
Ajit Nandawadekar
MSMukhtiar Singh
Mukhtiar Singh
SKSoumen Kar
Soumen Kar
A multi-coil superconducting magnet is the heart of any modern Magnetic Resonance Imaging (MRI) scanner. The superconducting magnet in MRI produces a highly homogeneous field (±5 ppm) and stable field (<0.1 ppm/h) in its imaging volume. The temporal field stability depends on the electrical resistance of the inter-coil joints and the electrical resistance of the joint between the coil and the superconducting switch. To establish the joint technology, a 4 K test rig is required for testing the sample joints. This paper briefly discusses the details of the versatile 4 K insert recently developed at IUAC for the characterization of the superconducting joints using the field-decay measurement technique. It can measure the joint resistance up to ∼10−15 Ω in a straight or spiral joint configuration with lengths up to 150 mm. The maximum current that can be induced on the test coil is more than 600 A for the field-decay measurement. The behavior of the joint resistance can also be studied in the presence of a 1.5 T background field. We have characterized many superconducting joints using this versatile 4 K insert. The joints between two different conductors can also be studied using this 4 K insert. The lowest joint resistance measured is 8 × 10−15 Ω at zero field. The joint resistance is also measured in the presence of the background field.

9 March 2026 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ANAjit Nandawadekar
Ajit Nandawadekar
SCSara Casalbuoni
Sara Casalbuoni
PZPawel Ziolkowski
Pawel Ziolkowski
EFEnrico Fioresi
Enrico Fioresi
Superconducting undulators (SCUs) offer significant advantages for storage rings and free-electron laser (FEL) facilities by providing approximately three times stronger magnetic field compared to permanent-magnet undulators for the same period length and vacuum gap. This increase in field strength enhances the tunability of the photon energy over a wider range for a given electron beam energy. A compact short superconducting undulator coil mockup with 15 mm period length satisfying requirements for applications in the European XFEL is designed for a test in liquid helium. This contribution presents the magnetic design and the theoretical quench analysis.