1 June 2012 in Sleep Medicine Reviews
1 September 2018 in Physiological Measurement
Objective : Use of wearable ECG devices for arrhythmia screening is limited due to poor signal quality, small number of leads and short records, leading to incorrect recognition of pathological events. This paper introduces a novel approach to classification (normal/‘N’, atrial fibrillation/‘A’, other/‘O’, and noisy/‘P’) of short single-lead ECGs recorded by wearable devices. Approach : Various rhythm and morphology features are derived from the separate beats (‘local’ features) as well as the entire ECGs (‘global’ features) to represent short-term events and general trends respectively. Various types of atrial and ventricular activity, heart beats and, finally, ECG records are then recognised by a multi-level approach combining a support vector machine (SVM), decision tree and threshold-based rules. Main results : The proposed features are suitable for the recognition of ‘A’. The method is robust due to the noise estimation involved. A combination of radial and linear SVMs ensures both high predictive performance and effective generalisation. Cost-sensitive learning, genetic algorithm feature selection and thresholding improve overall performance. The generalisation ability and reliability of this approach are high, as verified by cross-validation on a training set and by blind testing, with only a slight decrease of overall F1-measure, from 0.84 on training to 0.81 on the tested dataset. ‘O’ recognition seems to be the most difficult (test F1-measures: 0.90/‘N’, 0.81/‘A’ and 0.72/‘O’) due to high inter-patient variability and similarity with ‘N’. Significance : These study results contribute to multidisciplinary areas, focusing on creation of robust and reliable cardiac monitoring systems in order to improve diagnosis, reduce unnecessary time-consuming expert ECG scoring and, consequently, ensure timely and effective treatment.
8 April 2015 in Cardiovascular Engineering and Technology
4 August 2017 in BMC Cardiovascular Disorders
Detailed quantitative analysis of the effect of left ventricle (LV) hypertrophy on myocardial ischemia manifestation in ECG is still missing. The associations between both phenomena can be studied in animal models. In this study, rabbit isolated hearts with spontaneously increased LV mass were used to evaluate the effect of such LV alteration on ischemia detection criteria and performance. Electrophysiological effects of increased LV mass were evaluated on sixteen New Zealand rabbit isolated hearts under non-ischemic and ischemic conditions by analysis of various electrogram (EG) parameters. To reveal hearts with increased LV mass, LV weight/heart weight ratio was proposed. Standard paired and unpaired statistical tests and receiver operating characteristics analysis were used to compare data derived from different groups of animals, monitor EG parameters during global ischemia and evaluate their ability to discriminate between unchanged and increased LV as well as non-ischemic and ischemic state. Successful evaluation of both increased LV mass and ischemia is lead-dependent. Particularly, maximal deviation of QRS and area under QRS associated with anterolateral heart wall respond significantly to even early phase (the 1st-3rd min) of ischemia. Besides ischemia, these parameters reflect increased LV mass as well (with sensitivity reaching approx. 80%). However, the sensitivity of the parameters to both phenomena may lead to misinterpretations, when inappropriate criteria for ischemia detection are selected. Particularly, use of cut-off-based criteria defined from control group for ischemia detection in hearts with increased LV mass may result in dramatic reduction (approx. 15%) of detection specificity due to increased number of false positives. Nevertheless, criteria adjusted to particular experimental group allow achieving ischemia detection sensitivity of 89–100% and specificity of 94–100%, respectively. It was shown that response of the heart to myocardial ischemia can be successfully evaluated only when taking into account heart-related factors (such as LV mass) and other methodological aspects (such as recording electrodes position, selected EG parameters, cut-off criteria, etc.). Results of this study might be helpful for developing new clinical diagnostic strategies in order to improve myocardial ischemia detection in patients with LV hypertrophy.
3 November 2015 in Artificial Organs