Andrea Němcová

Mrs. Andrea Němcová

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2020 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
ANAndrea Němcová
Andrea Němcová
VSVeronika Svozilova
Veronika Svozilova
KBKaterina Bucsuhazy
Katerina Bucsuhazy
RSRadovan Smisek
Radovan Smisek
MMMartin Mezl
Martin Mezl
RKRadim Kolář
Radim Kolář
Driver fatigue and stress significantly contribute to higher number of car accidents worldwide. Although, different detection approaches have been already commercialized and used by car producers (and third party companies), research activities in this field are still needed in order to increase the reliability of these alert systems. Also, in the context of automated driving, the driver mental state assessment will be an important part of cars in future. This paper presents state-of-the-art review of different approaches for driver fatigue and stress detection and evaluation. We describe in details various signals (biological, car and video) and derived features used for these tasks and we discuss their relevance and advantages. In order to make this review complete, we also describe different datasets, acquisition systems and experiment scenarios.

1 May 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
ANAndrea Němcová
Andrea Němcová
IJIvana Jordanova
Ivana Jordanova
MVMartin Varecka
Martin Varecka
RSRadovan Smisek
Radovan Smisek
LMLucie Marsanova
Lucie Marsanova
MVMartin Vitek
Martin Vitek

27 January 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LSLukas Smital
Lukas Smital
CHClifton Haider
Clifton Haider
MVMartin Vitek
Martin Vitek
PLPavel Leinveber
Pavel Leinveber
PJPavel Jurak
Pavel Jurak
DHDavid R. Holmes
David R. Holmes
Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.

11 September 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LMLucie Maršánová
Lucie Maršánová
MRMarina Ronzhina
Marina Ronzhina
RSRadovan Smisek
Radovan Smisek
MVMartin Vítek
Martin Vítek
ANAndrea Němcová
Andrea Němcová
MNMarie Nováková
Marie Nováková
Accurate detection of cardiac pathological events is an important part of electrocardiogram (ECG) evaluation and subsequent correct treatment of the patient. The paper introduces the results of a complex study, where various aspects of automatic classification of various heartbeat types have been addressed. Particularly, non-ischemic, ischemic (of two different grades) and subsequent ventricular premature beats were classified in this combination for the first time. ECGs recorded in rabbit isolated hearts under non-ischemic and ischemic conditions were used for analysis. Various morphological and spectral features (both commonly used and newly proposed) as well as classification models were tested on the same data set. It was found that: a) morphological features are generally more suitable than spectral ones; b) successful results (accuracy up to 98.3% and 96.2% for morphological and spectral features, respectively) can be achieved using features calculated without time-consuming delineation of QRS-T segment; c) use of reduced number of features (3 to 14 features) for model training allows achieving similar or even better performance as compared to the whole feature sets (10 to 29 features); d) k-nearest neighbours and support vector machine seem to be the most appropriate models (accuracy up to 98.6% and 93.5%, respectively).

18 July 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
ANAndrea Němcová
Andrea Němcová
RSRadovan Smisek
Radovan Smisek
LMLucie Maršánová
Lucie Maršánová
LSLukáš Smital
Lukáš Smital
MVMartin Vítek
Martin Vítek
The assessment of ECG signal quality after compression is an essential part of the compression process. Compression facilitates the signal archiving, speeds up signal transmission, and reduces the energy consumption. Conversely, lossy compression distorts the signals. Therefore, it is necessary to express the compression performance through both compression efficiency and signal quality. This paper provides an overview of objective algorithms for the assessment of both ECG signal quality after compression and compression efficiency. In this area, there is a lack of standardization, and there is no extensive review as such. 40 methods were tested in terms of their suitability for quality assessment. For this purpose, the whole CSE database was used. The tested signals were compressed using an algorithm based on SPIHT with varying efficiency. As a reference, compressed signals were manually assessed by two experts and classified into three quality groups. Owing to the experts’ classification, we determined corresponding ranges of selected quality evaluation methods’ values. The suitability of the methods for quality assessment was evaluated based on five criteria. For the assessment of ECG signal quality after compression, we recommend using a combination of these methods: PSim SDNN, QS, SNR1, MSE, PRDN1, MAX, STDERR, and WEDD SWT.

1 January 2021 in BioMed Research International
Verified
Journal Article
Open access
PDF file
ANAndrea Němcová
Andrea Němcová
EVEnikö Vargova
Enikö Vargova
RSRadovan Smisek
Radovan Smisek
LMLucie Marsanova
Lucie Marsanova
LSLukas Smital
Lukas Smital
MVMartin Vitek
Martin Vitek
To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10‐second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user‐friendly, cheap, on‐the‐spot, self‐home‐monitoring of heart rate with the potential of widespread using.