Radovan Smisek

Mr. Radovan Smisek

Brno University of Technology, Faculty of Electrical Engineering and Communication
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2020 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
ANAndrea Němcová
Andrea Němcová
VSVeronika Svozilova
Veronika Svozilova
KBKaterina Bucsuhazy
Katerina Bucsuhazy
RSRadovan Smisek
Radovan Smisek
MMMartin Mezl
Martin Mezl
RKRadim Kolář
Radim Kolář
Driver fatigue and stress significantly contribute to higher number of car accidents worldwide. Although, different detection approaches have been already commercialized and used by car producers (and third party companies), research activities in this field are still needed in order to increase the reliability of these alert systems. Also, in the context of automated driving, the driver mental state assessment will be an important part of cars in future. This paper presents state-of-the-art review of different approaches for driver fatigue and stress detection and evaluation. We describe in details various signals (biological, car and video) and derived features used for these tasks and we discuss their relevance and advantages. In order to make this review complete, we also describe different datasets, acquisition systems and experiment scenarios.

1 August 2021 in Heart Rhythm
Verified
Journal Article
Open access
KCkarol curila
karol curila
PJPavel Jurak
Pavel Jurak
MJMarek Jastrzebski
Marek Jastrzebski
FPFrits Prinzen
Frits Prinzen
PWPetr Waldauf
Petr Waldauf
POPavel Osmancik
Pavel Osmancik
Nonselective His-bundle pacing (nsHBp), nonselective left bundle branch pacing (nsLBBp), and left ventricular septal myocardial pacing (LVSP) are recognized as physiological pacing techniques. The purpose of this study was to compare differences in ventricular depolarization between these techniques using ultra-high-frequency electrocardiography (UHF-ECG). In patients with bradycardia, nsHBp, nsLBBp (confirmed concomitant left bundle branch [LBB] and myocardial capture), and LVSP (pacing in left ventricular [LV] septal position without proven LBB capture) were performed. Timings of ventricular activations in precordial leads were displayed using UHF-ECG, and electrical dyssynchrony (e-DYS) was calculated as the difference between the first and last activation. Duration of local depolarization (Vd) was determined as width of the UHF-QRS complex at 50% of its amplitude. In 68 patients, data were collected during nsLBBp (35), LVSP (96), and nsHBp (55). nsLBBp resulted in larger e-DYS than did LVSP and nsHBp [- 24 ms (-28;-19) vs -12 ms (-16;-9) vs 10 ms (7;14), respectively; P <.001]. nsLBBp produced similar values of Vd in leads V5-V8 (36-43 ms vs 38-43 ms; P = NS in all leads) but longer Vd in leads V1-V4 (47-59 ms vs 41-44 ms; P <.05) as nsHBp. LVSP caused prolonged Vd in leads V1-V8 compared to nsHBp and longer Vd in leads V5-V8 compared to nsLBBp (44-51 ms vs 36-43 ms; P <.05) regardless of R-wave peak time in lead V5 or QRS morphology in lead V1 present during LVSP. nslbbp preserves physiological LV depolarization but increases interventricular electrical dyssynchrony. LV lateral wall depolarization during LVSP is prolonged, but interventricular synchrony is preserved.

1 May 2020 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
ANAndrea Němcová
Andrea Němcová
IJIvana Jordanova
Ivana Jordanova
MVMartin Varecka
Martin Varecka
RSRadovan Smisek
Radovan Smisek
LMLucie Marsanova
Lucie Marsanova
MVMartin Vitek
Martin Vitek

27 January 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LSLukas Smital
Lukas Smital
CHClifton Haider
Clifton Haider
MVMartin Vitek
Martin Vitek
PLPavel Leinveber
Pavel Leinveber
PJPavel Jurak
Pavel Jurak
DHDavid R. Holmes
David R. Holmes
Nowadays, methods for ECG quality assessment are mostly designed to binary distinguish between good/bad quality of the whole signal. Such classification is not suitable to long-term data collected by wearable devices. In this paper, a novel approach to estimate long-term ECG signal quality is proposed. The real-time quality estimation is performed in a local time window by calculation of continuous signal-to-noise ratio (SNR) curve. The layout of the data quality segments is determined by analysis of SNR waveform. It is distinguished between three levels of ECG signal quality: signal suitable for full wave ECG analysis, signal suitable only for QRS detection, and signal unsuitable for further processing. The SNR limits for reliable QRS detection and full ECG waveform analysis are 5 and 18 dB respectively. The method was developed and tested using synthetic data and validated on real data from wearable device. The proposed solution is a robust, accurate and computationally efficient algorithm for annotation of ECG signal quality that will facilitate the subsequent tailored analysis of ECG signals recorded in free-living conditions. The field of long-term ECG signals self-monitoring by wearable devices is swiftly developing. The analysis of massive amount of collected data is time consuming. It is advantageous to characterize data quality in advance and thereby limit consequent analysis to useable signals.

17 February 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LHLuuk Heckman
Luuk Heckman
JLJustin G.L.M. Luermans
Justin G.L.M. Luermans
KCkarol curila
karol curila
ASAntonius M.W. Van Stipdonk
Antonius M.W. Van Stipdonk
SWS.W. Westra
S.W. Westra
KVKevin Vernooy
Kevin Vernooy
Background: Left bundle branch area pacing (LBBAP) has recently been introduced as a novel physiological pacing strategy. Within LBBAP, distinction is made between left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP, no left bundle capture). Objective: To investigate acute electrophysiological effects of LBBP and LVSP as compared to intrinsic ventricular conduction. Methods: Fifty patients with normal cardiac function and pacemaker indication for bradycardia underwent LBBAP. Electrocardiography (ECG) characteristics were evaluated during pacing at various depths within the septum: starting at the right ventricular (RV) side of the septum: the last position with QS morphology, the first position with r’ morphology, LVSP and—in patients where left bundle branch (LBB) capture was achieved—LBBP. From the ECG’s QRS duration and QRS morphology in lead V1, the stimulus- left ventricular activation time left ventricular activation time (LVAT) interval were measured. After conversion of the ECG into vectorcardiogram (VCG) (Kors conversion matrix), QRS area and QRS vector in transverse plane (Azimuth) were determined. Results: QRS area significantly decreased from 82 ± 29 µVs during RV septal pacing (RVSP) to 46 ± 12 µVs during LVSP. In the subgroup where LBB capture was achieved (n = 31), QRS area significantly decreased from 46 ± 17 µVs during LVSP to 38 ± 15 µVs during LBBP, while LVAT was not significantly different between LVSP and LBBP. In patients with normal ventricular activation and narrow QRS, QRS area during LBBP was not significantly different from that during intrinsic activation (37 ± 16 vs. 35 ± 19 µVs, respectively). The Azimuth significantly changed from RVSP (−46 ± 33°) to LVSP (19 ± 16°) and LBBP (−22 ± 14°). The Azimuth during both LVSP and LBBP were not significantly different from normal ventricular activation. QRS area and LVAT correlated moderately (Spearman’s R = 0.58). Conclusions: ECG and VCG indices demonstrate that both LVSP and LBBP improve ventricular dyssynchrony considerably as compared to RVSP, to values close to normal ventricular activation. LBBP seems to result in a small, but significant, improvement in ventricular synchrony as compared to LVSP.

11 September 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
LMLucie Maršánová
Lucie Maršánová
MRMarina Ronzhina
Marina Ronzhina
RSRadovan Smisek
Radovan Smisek
MVMartin Vítek
Martin Vítek
ANAndrea Němcová
Andrea Němcová
MNMarie Nováková
Marie Nováková
Accurate detection of cardiac pathological events is an important part of electrocardiogram (ECG) evaluation and subsequent correct treatment of the patient. The paper introduces the results of a complex study, where various aspects of automatic classification of various heartbeat types have been addressed. Particularly, non-ischemic, ischemic (of two different grades) and subsequent ventricular premature beats were classified in this combination for the first time. ECGs recorded in rabbit isolated hearts under non-ischemic and ischemic conditions were used for analysis. Various morphological and spectral features (both commonly used and newly proposed) as well as classification models were tested on the same data set. It was found that: a) morphological features are generally more suitable than spectral ones; b) successful results (accuracy up to 98.3% and 96.2% for morphological and spectral features, respectively) can be achieved using features calculated without time-consuming delineation of QRS-T segment; c) use of reduced number of features (3 to 14 features) for model training allows achieving similar or even better performance as compared to the whole feature sets (10 to 29 features); d) k-nearest neighbours and support vector machine seem to be the most appropriate models (accuracy up to 98.6% and 93.5%, respectively).