Ifte Khairul Amin

Ifte Khairul Amin

Auto-generated profile, based on publicly available information

Ifte Khairul Amin

Shahjalal University of Science and Technology, Sylhet, Bangladesh

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NRNima Rezaei
Nima Rezaei
MUMohammad Nasir Uddin
Mohammad Nasir Uddin
IAIfte Khairul Amin
Ifte Khairul Amin
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
MMMarayati Marsadek
Marayati Marsadek

29 February 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
Mohammad Kamruzzaman Khan PrinceMohammad Kamruzzaman Khan Prince
Mohammad Kamruzzaman Khan Prince
Mohammad Taufiqul ArifMohammad Taufiqul Arif
Mohammad Taufiqul Arif
AGAmeen Gargoom
Ameen Gargoom
MAMuhammad Waseem Altaf
Muhammad Waseem Altaf
IAIfte Khairul Amin
Ifte Khairul Amin
Enamul HaqueEnamul Haque
Enamul Haque
This paper designs three coordinated control schemes for a grid-connected wind energy conversion system based on a permanent magnet synchronous generator. The system includes a static synchronous compensator (STATCOM) and a supercapacitor energy storage (SCES) to maintain stable operation during different operating conditions. Coordinated control scheme-I (CCS-I) integrates the SCES into the DC-link via a bidirectional DC/DC converter to stabilize the voltage under varying wind speeds and grid disturbances. Coordinated control scheme-II (CCS-II) uses a STATCOM at the point of common coupling (PCC) to enhance the grid voltage stability during voltage sag or swell, where the SCES balances active power, and the grid side converter (GSC) provides reactive power support. The STATCOM is only activated when the PCC's reactive power requirement exceeds the GSC's support capacity. Coordinated control scheme-III (CCS-III) considers simultaneous disturbances on both the wind turbine and grid side to stabilize the DC-link and grid voltage. The proposed control schemes have been experimentally implemented with a dSpace MicroLabBox. Additionally a Lyapunov function based stability analysis of the system including the SCES is presented in the paper.

27 April 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
NRNima Rezaei
Nima Rezaei
MUMohammad Nasir Uddin
Mohammad Nasir Uddin
KIKhairul Amin Ifte
Khairul Amin Ifte
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
MMMARAYATI BINTI MARSADEK
MARAYATI BINTI MARSADEK
MHMehedi Hasan
Mehedi Hasan
The protection of intertie zone between wind farm and grid line is critical for stable and safe operation of both the grid line and wind farm in the event of fault within or outside the intertie zone. As a reliable source of renewable energy doubly fed induction generator (DFIG) based wind farms have been increasingly integrated to the power grid over the last two decades. Nowadays with the enormous penetration of large-scale DFIG wind farms, the commonly used distance relays are no longer reliable due to their incapability of providing accurate impedance measurement during internal and external faults. Thus, it results in maloperation, false tripping and/or delayed operation. Therefore, in this paper a digital differential-based protective relay (DBPR) scheme is designed and developed to provide reliable protection for wind farm intertie zone. Additionally, a new Bayesian-based optimized Support Vector Machine (SVM) as a supervised machine learning classifier approach is developed to take into account both the dynamic behaviors of wind speed and the current measured by the current transformers. Thus, the proposed hybrid SVM-DBPR scheme can distinguish among the normal operation, internal and external faults correctly that helps to avoid any false tripping. In a laboratory environment the proposed DBPR is implemented in real-time using FPGA DE2-115 board equipped with Cyclone IV-E device (EP4CE115F29C7). It is found from both simulation and experimental results that the proposed hybrid SVM-DBPR is able to provide reliable, efficient and robust protection for the intertie zone of wind farms with 97.5% accuracy rate.

22 November 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
IAIfte Khairul Amin
Ifte Khairul Amin
MUMohammad Nasir Uddin
Mohammad Nasir Uddin
This paper presents a novel adaptive backstepping based nonlinear control scheme incorporated with machine loss reduction and parameter uncertainties for grid-connected doubly fed induction generator (DFIG) driven wind energy conversion system (WECS). The proposed nonlinear controller is developed to stabilize both the grid and rotor side current control loops of direct-drive DFIG based WECS. Traditional feedback linearization controllers are sensitive to system parameter variations and disturbances on DFIG based WECS, which demands advanced control techniques for stable and efficient performance considering the nonlinear system dynamics. The proposed nonlinear controller incorporates the system uncertainty and nonlinearities in the design stage while ensuring the stability of the drive system through Lyapunov stability criteria. A machine loss reduction algorithm is also incorporated in the design to achieve enhanced efficiency. The performance of the proposed nonlinear scheme is compared with conventional benchmark fixed gain PI control and sliding mode control scheme for the RSC controller. The proposed nonlinear controller for DFIG based WECS integrated with machine loss reduction scheme is successfully implemented in real-time using DSP board DS 1104 for a prototype 350W DFIG. The simulation and experimental results prove the efficacy of the proposed scheme under variable operating conditions such as wind speed variation, grid voltage disturbances and parameter uncertainties.

23 May 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MUMohammad Nasir Uddin
Mohammad Nasir Uddin
ZZZhuoqun Zhai
Zhuoqun Zhai
IAIfte Khairul Amin
Ifte Khairul Amin
This paper presents a port controlled Hamilton with dissipation (PCHD) based control technique for high precision speed regulation of interior permanent magnet synchronous motor (IPMSM) drive. The PCHD controller is designed by assigning proper interconnection and damping matrix for multivariate, nonlinear and time-varying IPMSM system to prove its passivity and ensure its global stability. A torque observer is also designed based on pole placement method to monitor the external load. The stability analysis of the proposed PCHD and uniformity between the proposed controller and PI controller are analyzed subsequently. The performance of the proposed controller is investigated in both simulation and experimental environment using MATLAB-Simulink and dSPACE DS1104 board, respectively, at different operating conditions for a laboratory 5 hp motor. It is found that the proposed PCHD controller shows better performance than that of the conventional benchmark tuned PI controller in terms of speed tracking capability with load variations.

14 December 2018 in Electric Power Components and Systems
Verified
Journal Article
Closed access
MUMohammad Nasir Uddin
Mohammad Nasir Uddin
IAIfte Khairul Amin
Ifte Khairul Amin
One of the major challenges in harnessing wind energy is to extract maximum power from intermittent generation of wind farms as wind power generation strongly depends on wind speed variation. Among different maximum power point tracking (MPPT) algorithms, traditionally, hill climb search (HCS) method is widely used because of its simple implementation and turbine parameter-independence. However, the conventional HCS algorithm has some drawbacks such as power fluctuation and speed-efficiency tradeoff. Similarly constant tip-speed ratio (TSR) MPPT control method requires precise knowledge of optimal TSR of the turbine. Therefore, in this paper a new adaptive step size based HCS controller is proposed to mitigate the deficiencies of other techniques by incorporating wind speed measurement. The function-based adaptive control scheme evaluates the step size by the variation of the wind speed and extracted power range. The proposed variable step size based HCS-MPPT system is simulated at variable wind speed. A prototype system is also built with a low-power doubly-fed induction generator (DFIG). It is found from the results that the proposed controller reduces the steady-state power fluctuation of the DFIG based wind energy conversion system significantly compared to the conventional HCS-MPPT controller and constant TSR based MPPT controller at variable wind speeds.