Alessandro Spoladore

Alessandro Spoladore

Auto-generated profile, based on publicly available information

Alessandro Spoladore

DIME—Dipartimento di Ingegneria Meccanica, Energetica, Gestionale e dei Trasporti, Università degli Studi di Genova, Via All’Opera Pia 15/A, 16145 Genova, Italy

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2016 in Energies
Verified
Journal Article
Open access
PDF file
Davide BorelliDavide Borelli
Davide Borelli
FDFrancesco Devia
Francesco Devia
ECErmanno Lo Cascio
Ermanno Lo Cascio
Corrado SchenoneCorrado Schenone
Corrado Schenone
ASAlessandro Spoladore
Alessandro Spoladore
Within the framework of the European Combined Efficient Large Scale Integrated Urban Systems (CELSIUS) project, the Genoa demonstrator involves the insertion of a turbo expander (TE) to substitute the standard throttling process in a natural gas expansion station. In this way, the currently wasted mechanical energy will be recovered, while an internal combustion combined heat and power (CHP) unit will be used to meet the heating requirements of the gas before the expansion and to serve a small district heating network (DHN). Both TE and CHP are capable of delivering electric power (EP) up to 1 MW. In order to match the EP production vs demand is highly desirable to use the EP extra capacity for local EP final users, such as a nearby public school and a gas refueling station (RS). For limiting the school’s consumption of fossil fuel, it is possible to use the EP surplus generated by the demonstrator to feed a heat pump in parallel to the heating conventional system. With regard to the RS, the compressors are currently driven by electric motors, with a high-energy consumption. The integrated system gives the possibility of exploiting the surplus of electricity production and of recovering heat, which would be otherwise wasted, from the intercooling of compressed gas, thus powering the DHN through a preheating system. The result expected from this strategy is a relevant energy and emissions saving due to an integrated use of the electricity generated by the Genoese demonstrator for feeding the nearby school and RS.

18 December 2015 in Sustainability
Verified
Journal Article
Open access
PDF file
Davide BorelliDavide Borelli
Davide Borelli
FDFrancesco Devia
Francesco Devia
MBMargherita Marré Brunenghi
Margherita Marré Brunenghi
Corrado SchenoneCorrado Schenone
Corrado Schenone
ASAlessandro Spoladore
Alessandro Spoladore
Increasing energy efficiency by the smart recovery of waste energy is the scope of the CELSIUS Project (Combined Efficient Large Scale Integrated Urban Systems). The CELSIUS consortium includes a world-leading partnership of outstanding research, innovation and implementation organizations, and gather competence and excellence from five European cities with complementary baseline positions regarding the sustainable use of energy: Cologne, Genoa, Gothenburg, London, and Rotterdam. Lasting four-years and coordinated by the City of Gothenburg, the project faces with an holistic approach technical, economic, administrative, social, legal and political issues concerning smart district heating and cooling, aiming to establish best practice solutions. This will be done through the implementation of twelve new high-reaching demonstration projects, which cover the most major aspects of innovative urban heating and cooling for a smart city. The Genoa demonstrator was designed in order to recover energy from the pressure drop between the main supply line and the city natural gas network. The potential mechanical energy is converted to electricity by a turboexpander/generator system, which has been integrated in a combined heat and power plant to supply a district heating network. The performed energy analysis assessed natural gas saving and greenhouse gas reduction achieved through the smart systems integration.

20 September 2017 in International Journal of Heat and Technology
Verified
Journal Article
Open access
SCSanto Cogliandro
Santo Cogliandro
CCCarlo Cravero
Carlo Cravero
Martino MariniMartino Marini
Martino Marini
ASAlessandro Spoladore
Alessandro Spoladore

1 December 2015 in Energy Procedia
Verified
Journal Article
Open access
DBDavide Borelli
Davide Borelli
FDFrancesco Devia
Francesco Devia
CSCorrado Schenone
Corrado Schenone
ASAlessandro Spoladore
Alessandro Spoladore
In this paper a numerical model aimed at studying dynamic behavior of CHP (Combined Heat and Power) plants is presented, paying particular attention to the components in which heat transfers take place. The analysis refers to a system powered by an internal combustion engine for a compression ignition type in cogeneration configuration, equipped with two heat extractors: the first one for coolant / water, the second one for exhaust gas / water. The numerical model has been implemented by using Matlab-Simulink software. After a description of the simplifying assumptions adopted for implementing the simulator, the model is exposed in detail with regards to each single element. Then simulation results are reported for two different operating conditions aiming to assess the effectiveness of the model in analyzing the dynamic behavior of CHP plants

10 April 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Carlo CraveroCarlo Cravero
Carlo Cravero
ASAlessandro Spoladore
Alessandro Spoladore
The glass production industry has one of the highest energy consumption rates and environmental emission impacts with respect to the existing industrial sectors. Glass furnaces nowadays are conceived with regenerative systems to take advantage of the residual heat from the combustion exhausts in order to increase the thermal efficiency of the system. The exhaust gases are also used in innovative systems to reduce the NOx emissions in specifically designed gas recirculation systems tailored to the glass furnace. In this paper, a numerical model for the simulation of the regenerative chambers in both steady and unsteady conditions is presented. The option of gas recirculation is also included. Special attention has been focused on the radiative heat transfer from the recirculated gases using a gas emissivity model previously developed by the authors.