Wenhua Wu

Wenhua Wu

Auto-generated profile, based on publicly available information

Wenhua Wu

College of Electrical and Information Engineering, Hunan University, Changsha, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WWWenhua Wu
Wenhua Wu
LZLeming Zhou
Leming Zhou
YCYandong Chen
Yandong Chen
ALAn Luo
An Luo
YDYanting Dong
Yanting Dong
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Traditional grid-connected inverters (TGCI) could suffer from small-signal instability owing to the dynamic interactions among inverters and a weak grid. In this letter, the small-signal sequence impedance model of the virtual synchronous generator (VSG) is built, and the sequence impedance characteristics of the VSG and the TGCI are compared and analyzed. The sequence impedance of the TGCI is mainly capacitive in the middle-frequency area, and the impedance amplitude is quite high. By contrast, the sequence impedance of the VSG, being consistent with the grid impedance characteristics, is generally inductive, and the impedance amplitude is quite low. Based on the sequence impedance model and the Nyquist stability criterion, the influence of the grid stiffness, the number of paralleled inverters, and the phase-locked loop (PLL) bandwidth on the stability of the VSG and the TGCI systems is analyzed. The stability analysis results show that the TGCI loses stability easily, whereas the VSG still works well without PLL restrictions under an ultraweak grid or with a large number of inverters connected to the grid. Therefore, the VSG is more suitable than the TGCI for achieving high penetration of renewable energy generation in an ultraweak grid from a system stability viewpoint. Finally, the experimental results validate the sequence impedance model and the stability analysis.

8 October 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
WWWenhua Wu
Wenhua Wu
MZMingmin Zhang
Mingmin Zhang
YCYandong Chen
Yandong Chen
LZLeming Zhou
Leming Zhou
ALAn Luo
An Luo
JLJinming Liu
Jinming Liu
The premise that the virtual synchronous generator (VSG) can actively support the weak grid is that the VSG can operate stably. In this paper, the small-signal sequence impedance models of the voltage-controlled VSG and the current-controlled VSG are built and the sequence impedance characteristics of these two types of VSGs are compared and analyzed. The sequence impedance of the voltage-controlled VSG, being consistent with the grid impedance characteristics, is generally inductive. By contrast, the sequence impedance of the current-controlled VSG is mainly negative impedance in the middle- and high-frequency areas and the impedance amplitude is quite low. Based on the built sequence impedance models and the impedance stability criterion, the influence of the weakness of the grid on the stability of these two types of VSG grid-connected system is analyzed. The results of stability analysis show that the current-controlled VSG is prone to instability while the voltage-controlled VSG remains stable. Therefore, the voltage-controlled VSG is more suitable than the current-controlled VSG for grid-connected renewable energy generation in an ultra-weak grid from the point of view of system stability. Finally, experiment results validate the stability analysis.

3 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Gaoxiang LiGaoxiang Li
Gaoxiang Li
YCYandong Chen
Yandong Chen
ALAn Luo
An Luo
ZHZhixing He
Zhixing He
HWHaining Wang
Haining Wang
LZLeming Zhou
Leming Zhou
Analogizing the sub-synchronous resonance (SSR) phenomenon of the series-compensated grid-connected system based on synchronous generator, the virtual synchronous generator (VSG) also has the low-frequency oscillation problem owing to the impedance interaction between VSG and series-compensated network. Stability of the series-compensated grid-connected system controlled by VSG is analyzed by the impedance-based Nyquist stability criterion. Due to the inductive impedance of VSG, VSG is easy to couple with the series-compensated network in the low-frequency areas, which can lead to the SSR. With the increase of the series compensation level, the stability of VSG becomes worse and the induced oscillation frequency becomes higher. Therefore, a mod-ulation signal feedforward active damping control strategy with time delay compensation is proposed to suppress this SSR, which directly feeds the active-damping control signal to the PWM modulator for reshaping the output impedance of VSG from the inductance to the resistance-inductance. Moreover, a value range of virtual resistance is given with considering the influence on the regular operation of VSG. Finally, simulation and experimental results verify the correctness of the SSR analysis and the feasibility of the proposed active-damping control strategy.

31 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JGJian Guo
Jian Guo
YCYandong Chen
Yandong Chen
LWLei Wang
Lei Wang
WWWenhua Wu
Wenhua Wu
XWXiangyu Wang
Xiangyu Wang
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
In recent years, the virtual synchronous generator (VSG) concept has been widely studied to integrate renewable energy sources. However, instability occurs due to the implementation of the dc-link voltage controllers under the weak grid, and its mechanism remains unclear, which is investigated in this article. At first, the wideband dq -frame impedance models of the VSGs with the dc-link voltage controllers for two cases are established. Then, the stability analyses of the VSGs are compared based on these impedance models. It is revealed that the interaction dynamics between the dc-link voltage loop and the active loop lead to the negative resistor behavior of the q–q channel impedances for both VSGs, which induces the emerging oscillations of the system in a weak grid. Besides, as a useful design guideline, the parameter design of the VSGs is proposed to enhance the system stability. Finally, the experimental results obtained from a 100-kW prototype system show good agreement with simulated results, validating the impedance models and theoretical analysis.

23 January 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
LZLeming Zhou
Leming Zhou
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
XZXiaoping Zhou
Xiaoping Zhou
YCYandong Chen
Yandong Chen
ZLZhipeng Lv
Zhipeng Lv
ALAn Luo
An Luo
For the LCL-type grid-connected distributed generation system, the grid-current-feedback active damping (GCFAD) methods have a conflict between the resonance-suppression ability and harmonic-currents amplification. For this, an inverter-current-feedback reso-nance-suppression (ICFRS) method without additional sensors is proposed to reduce resonance-frequency offset and grid-inductance effect due to its unattenuated damping characteristic under high-frequency bandwidth. By analyzing two types of equivalent impedance models of ICFRS and GCFAD with a high-pass filter (HPF), GCFAD can suppress the resonance peak well only with a large resonance-frequency offset and might result in a narrow control bandwidth. However, ICFRS can suppress the resonance peak well with smaller resonance-frequency offset and maintain a high power quality compared with GCFAD. Considering the influence of control delay and grid inductance, the positive/negative critical point of an equivalent virtual resistance of ICFRS derived in the interval of [1/6, 1/3) is obtained, and a robust ICFRS is further proposed to improve system stability by maintaining a positive resistance regardless of grid-inductance variation. The stable-state and dynamic properties of the overall system are analyzed in detail in this paper, and its proper control parameters are selected without a complicated trial. Finally, simulation and experimental results verify the validity of the proposed method.

8 June 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
LZLeming Zhou
Leming Zhou
SLSiyi Liu
Siyi Liu
YCYandong Chen
Yandong Chen
WYWeilang Yi
Weilang Yi
SWShuke Wang
Shuke Wang
ALAoyang Liu
Aoyang Liu
For VSG, the voltage-controlled harmonic-suppression-method will seriously deteriorate the magnitude of inrush fault current in the moment of grid symmetrical fault, because the suppression effects of harmonic current and inrush fault current are mutually constrained from the perspective of its output impedance. For this issue, a harmonic current and inrush fault current coordinated suppression method is proposed to achieve both good results of harmonic current suppression in normal grid and inrush fault current limitation in fault grid, which mainly includes a passive branch, an active branch and an improved VSG control. The passive branch is installed between PCC and grid to introduce an additional voltage variable. Meanwhile, with the proper feed-forward of PCC voltage and additional voltage, the active branch increases the mid/high frequency impedance viewed from grid fault point to VSG, and decreases harmonic impedance viewed from PCC to VSG. Then, not only transient inrush fault current is limited, but also harmonic current introduced from nonlinear load is mostly absorbed. Moreover, the improved VSG control is used to limit steady-state fundamental frequency fault current. Therefore, the contradictory between harmonic current and inrush fault current suppression for VSG is well solved. Finally, the experiment results validate the proposed control method.