28 May 2018 in IEEE Transactions on Power Electronics
Traditional grid-connected inverters (TGCI) could suffer from small-signal instability owing to the dynamic interactions among inverters and a weak grid. In this letter, the small-signal sequence impedance model of the virtual synchronous generator (VSG) is built, and the sequence impedance characteristics of the VSG and the TGCI are compared and analyzed. The sequence impedance of the TGCI is mainly capacitive in the middle-frequency area, and the impedance amplitude is quite high. By contrast, the sequence impedance of the VSG, being consistent with the grid impedance characteristics, is generally inductive, and the impedance amplitude is quite low. Based on the sequence impedance model and the Nyquist stability criterion, the influence of the grid stiffness, the number of paralleled inverters, and the phase-locked loop (PLL) bandwidth on the stability of the VSG and the TGCI systems is analyzed. The stability analysis results show that the TGCI loses stability easily, whereas the VSG still works well without PLL restrictions under an ultraweak grid or with a large number of inverters connected to the grid. Therefore, the VSG is more suitable than the TGCI for achieving high penetration of renewable energy generation in an ultraweak grid from a system stability viewpoint. Finally, the experimental results validate the sequence impedance model and the stability analysis.
8 October 2018 in IEEE Transactions on Industrial Electronics
The premise that the virtual synchronous generator (VSG) can actively support the weak grid is that the VSG can operate stably. In this paper, the small-signal sequence impedance models of the voltage-controlled VSG and the current-controlled VSG are built and the sequence impedance characteristics of these two types of VSGs are compared and analyzed. The sequence impedance of the voltage-controlled VSG, being consistent with the grid impedance characteristics, is generally inductive. By contrast, the sequence impedance of the current-controlled VSG is mainly negative impedance in the middle- and high-frequency areas and the impedance amplitude is quite low. Based on the built sequence impedance models and the impedance stability criterion, the influence of the weakness of the grid on the stability of these two types of VSG grid-connected system is analyzed. The results of stability analysis show that the current-controlled VSG is prone to instability while the voltage-controlled VSG remains stable. Therefore, the voltage-controlled VSG is more suitable than the current-controlled VSG for grid-connected renewable energy generation in an ultra-weak grid from the point of view of system stability. Finally, experiment results validate the stability analysis.
3 March 2020 in IEEE Transactions on Power Electronics
Analogizing the sub-synchronous resonance (SSR) phenomenon of the series-compensated grid-connected system based on synchronous generator, the virtual synchronous generator (VSG) also has the low-frequency oscillation problem owing to the impedance interaction between VSG and series-compensated network. Stability of the series-compensated grid-connected system controlled by VSG is analyzed by the impedance-based Nyquist stability criterion. Due to the inductive impedance of VSG, VSG is easy to couple with the series-compensated network in the low-frequency areas, which can lead to the SSR. With the increase of the series compensation level, the stability of VSG becomes worse and the induced oscillation frequency becomes higher. Therefore, a mod-ulation signal feedforward active damping control strategy with time delay compensation is proposed to suppress this SSR, which directly feeds the active-damping control signal to the PWM modulator for reshaping the output impedance of VSG from the inductance to the resistance-inductance. Moreover, a value range of virtual resistance is given with considering the influence on the regular operation of VSG. Finally, simulation and experimental results verify the correctness of the SSR analysis and the feasibility of the proposed active-damping control strategy.
23 January 2018 in IEEE Transactions on Industrial Electronics
For the LCL-type grid-connected distributed generation system, the grid-current-feedback active damping (GCFAD) methods have a conflict between the resonance-suppression ability and harmonic-currents amplification. For this, an inverter-current-feedback reso-nance-suppression (ICFRS) method without additional sensors is proposed to reduce resonance-frequency offset and grid-inductance effect due to its unattenuated damping characteristic under high-frequency bandwidth. By analyzing two types of equivalent impedance models of ICFRS and GCFAD with a high-pass filter (HPF), GCFAD can suppress the resonance peak well only with a large resonance-frequency offset and might result in a narrow control bandwidth. However, ICFRS can suppress the resonance peak well with smaller resonance-frequency offset and maintain a high power quality compared with GCFAD. Considering the influence of control delay and grid inductance, the positive/negative critical point of an equivalent virtual resistance of ICFRS derived in the interval of [1/6, 1/3) is obtained, and a robust ICFRS is further proposed to improve system stability by maintaining a positive resistance regardless of grid-inductance variation. The stable-state and dynamic properties of the overall system are analyzed in detail in this paper, and its proper control parameters are selected without a complicated trial. Finally, simulation and experimental results verify the validity of the proposed method.
8 June 2020 in IEEE Transactions on Power Electronics
For VSG, the voltage-controlled harmonic-suppression-method will seriously deteriorate the magnitude of inrush fault current in the moment of grid symmetrical fault, because the suppression effects of harmonic current and inrush fault current are mutually constrained from the perspective of its output impedance. For this issue, a harmonic current and inrush fault current coordinated suppression method is proposed to achieve both good results of harmonic current suppression in normal grid and inrush fault current limitation in fault grid, which mainly includes a passive branch, an active branch and an improved VSG control. The passive branch is installed between PCC and grid to introduce an additional voltage variable. Meanwhile, with the proper feed-forward of PCC voltage and additional voltage, the active branch increases the mid/high frequency impedance viewed from grid fault point to VSG, and decreases harmonic impedance viewed from PCC to VSG. Then, not only transient inrush fault current is limited, but also harmonic current introduced from nonlinear load is mostly absorbed. Moreover, the improved VSG control is used to limit steady-state fundamental frequency fault current. Therefore, the contradictory between harmonic current and inrush fault current suppression for VSG is well solved. Finally, the experiment results validate the proposed control method.
12 February 2018 in IEEE Transactions on Industrial Informatics
In the maritime VSC-HVDC system supplying power to passive network on the island, the dc-side of the system is prone to oscillation and even instability, which is resulted from the negative incremental input resistance characteristic of the inverter station. Firstly, a virtual phase-lead impedance stability control strategy aiming at rectifier station is proposed. This control strategy can ef-fectively mitigate the dc-side oscillation of the VSC-HVDC system without affecting the load performance of the in-verter station. Then, the dc impedance model of the VSC-HVDC system is built, including the output impedance of the rectifier station, dc cable impedance and the input im-pedance of the inverter station. In addition, the oscillation mechanism of the VSC-HVDC system is analyzed by im-pedance-based Nyquist stability criterion. The reason why rectifier station fails to mitigate the dc-side oscillation us-ing traditional virtual resistance stability control is that the output impedance of the rectifier station exhibits negative damping characteristic outside the control bandwidth of voltage outer-loop. For this issue, the proposed control strategy can correct the output impedance of the rectifier station to exhibit positive damping characteristic outside the control bandwidth of voltage outer-loop, thus mitigating the dc-side oscillation of the VSC-HVDC system. Finally, simulation and experiment results validate the proposed control strategy and analysis.