In aeronautical jet engines, internal cooling is commonly employed to keep the blade surface temperature below the material's thermal limit to ensure the structural integrity and performance of turbine blades. This study aims to evaluate the heat transfer characteristics of internal cooling channel in gas turbine blades with perforated pin-fins compared to regular pin-fins (without perforated pin-fins) configurations using the Reynolds averaged Navier–Stokes equations with the k–ω turbulence model. The numerical results demonstrated that perforated pin-fins configurations increase the averaged Nusselt numbers (Nu¯) and heat transfer efficiency index = η and reduce friction factor (f) compared to the regular pin-fins. The cooling flow through the perforated pin-fins creates the jet-like flow, breaking the wake vortices behind the pin-fins near the heated endwalls surface and creating a high heat transfer zone. With the Reynolds numbers from 14 000 to 36 000, the numerical results of the perforated pin-fins (reference case) show an increase in Nu¯ and η by 61.28%–69.89% and 69.97%–80.19%, respectively, while f decreased by 14.56%–16.18% compared to the regular pin-fins. With perforated expansion at Re = 21,500, the heat transfer performance could be improved by up to 77.18% and the friction factor (f) was considerably reduced as low as 19.42% at WP/D = 0.8. This study provides valuable insights into the potential improvements in thermal performance achievable through perforated pin-fin configurations in gas turbine blade cooling channels.
For internal cooling of the turbine blade, pin-fin arrays located near the blade's trailing edge are essential for enhancing heat transfer and preserving structural integrity. However, the flat end wall of a conventional pin-fin channel tends to generate wake vortices, resulting in low heat transfer regions. To overcome this limitation, a new end wall design, termed the coupled trapezoidal ribbed end wall (CTRE), is proposed to improve overall heat transfer performance. Numerical simulations were performed by solving the Reynolds-averaged Navier–Stokes equations with the k−ω turbulence model. The CTRE design consists of an upstream rib and a downstream rib positioned lower and higher than the pin-fin base, respectively. The recirculating flow generated by the CTRE continuously interacts with the pin-fins and strengthens the horseshoe vortices, thereby expanding the high heat transfer regions. Moreover, the upward flow induced by the downstream rib interacts with the wake flow and weakens the wake vortices, further diminishing the low heat transfer regions behind the pin-fins. Consequently, the CTRE configuration yields a significant enhancement in the average Nusselt number (Nu) and the heat transfer efficiency index (HTEI), while introducing only a slight increase in the friction factor. Specifically, the new end wall design enhances average Nu by approximately 91.88%–103.04% and HTEI by 74.15%–78.05% over a Reynolds number range of Re=7400–36000. Six geometric parameters of the CTRE design were investigated, including the height, long-base length, and short-base length of the upstream and downstream ribs. The results provide valuable insights into the physical mechanisms associated with geometric variations.