Electric ducted fans are gaining prominence in aviation due to their compact size, low noise, and zero emissions compared to conventional gas turbines. This study presents an experimental test system for a 390 mm electric Ducted Propulsion Fan developed by the Aerospace Propulsion Systems group at Hanoi University of Science and Technology. The carbon fiber composite thruster, driven by a centrally located BLDC motor, was mounted on a test stand equipped with force and rotational speed (rpm) sensors. Power was supplied through two battery configurations, eight-pack and nine-pack, with voltage and current monitored and controlled via an ESC module. Experiments conducted from 2000 to 7000 rpm explored the relationship between electrical inputs and aero-propulsive outputs. The results revealed that input power, current, and sound pressure level (SPL) amplified meaningfully with rpm, while the voltage slightly declined. The maximum rpm reached 6500 rpm for the eight-pack and 7000 rpm for the nine-pack configurations. When greater than 6000 rpm, the SPL reaches close to 120 dB. The eight-pack configuration provided higher thrust per volt, whereas the nine-pack offered better thrust per ampere and improved starting power. Although dimensionless indices, including power coefficient (CP), thrust coefficient (CT), and figure of merit (FM), reduced with rpm, the FM remained between 0.7 and 0.75 at medium speeds, demonstrating effective energy conversion.
27 August 2024 in International Journal of Heat and Fluid Flow
In aeronautical jet engines, internal cooling is commonly employed to keep the blade surface temperature below the material's thermal limit to ensure the structural integrity and performance of turbine blades. This study aims to evaluate the heat transfer characteristics of internal cooling channel in gas turbine blades with perforated pin-fins compared to regular pin-fins (without perforated pin-fins) configurations using the Reynolds averaged Navier–Stokes equations with the k–ω turbulence model. The numerical results demonstrated that perforated pin-fins configurations increase the averaged Nusselt numbers (Nu¯) and heat transfer efficiency index = η and reduce friction factor (f) compared to the regular pin-fins. The cooling flow through the perforated pin-fins creates the jet-like flow, breaking the wake vortices behind the pin-fins near the heated endwalls surface and creating a high heat transfer zone. With the Reynolds numbers from 14 000 to 36 000, the numerical results of the perforated pin-fins (reference case) show an increase in Nu¯ and η by 61.28%–69.89% and 69.97%–80.19%, respectively, while f decreased by 14.56%–16.18% compared to the regular pin-fins. With perforated expansion at Re = 21,500, the heat transfer performance could be improved by up to 77.18% and the friction factor (f) was considerably reduced as low as 19.42% at WP/D = 0.8. This study provides valuable insights into the potential improvements in thermal performance achievable through perforated pin-fin configurations in gas turbine blade cooling channels.
Electric ducted fans are increasingly being applied in the aviation sector due to their advantages in compact size, low noise, and zero emissions when compared to conventional gas turbine engines. This paper presents a test system for an electric Ducted Propulsion Fan (eDPF) developed by the Aerospace Propulsion Systems group at the School of Mechanical Engineering, Hanoi University of Science and Technology, Vietnam. The core component of the experimental system is a 390 mm diameter eDPF, made of carbon fiber composite and driven by a BLDC electric motor located within the fan core. The eDPF is mounted on a test stand equipped with force sensors and an optical RPM sensor, which are connected to digital display gauges. The power supply consists of LiFePO₄ battery packs, with voltage and current monitored by multimeters and controlled via a potentiometer connected to an ESC module. This electric thruster was experimentally operated at rotational speeds ranging from 2000 rpm to 7000 rpm in order to establish the relationship between its electrical and aero-propulsion characteristics. Initially, the testing aimed to determine the operational thrust range of the eDPF. Subsequently, comparisons were made between the electrical and aero-propulsion performance, as well as dimensionless parameters—including power coefficient (CP), thrust coefficient (CT), and figure of merit (FM)—under two configurations: 8-pack and 9-pack battery setups. In addition, an acoustic test was performed to measure the sound pressure level (SPL) at a distance of 1.0 m. The experimental results provide insights and recommendations for operating the eDPF at different power levels to achieve optimal thrust efficiency.
For internal cooling of the turbine blade, pin-fin arrays located near the blade's trailing edge are essential for enhancing heat transfer and preserving structural integrity. However, the flat end wall of a conventional pin-fin channel tends to generate wake vortices, resulting in low heat transfer regions. To overcome this limitation, a new end wall design, termed the coupled trapezoidal ribbed end wall (CTRE), is proposed to improve overall heat transfer performance. Numerical simulations were performed by solving the Reynolds-averaged Navier–Stokes equations with the k−ω turbulence model. The CTRE design consists of an upstream rib and a downstream rib positioned lower and higher than the pin-fin base, respectively. The recirculating flow generated by the CTRE continuously interacts with the pin-fins and strengthens the horseshoe vortices, thereby expanding the high heat transfer regions. Moreover, the upward flow induced by the downstream rib interacts with the wake flow and weakens the wake vortices, further diminishing the low heat transfer regions behind the pin-fins. Consequently, the CTRE configuration yields a significant enhancement in the average Nusselt number (Nu) and the heat transfer efficiency index (HTEI), while introducing only a slight increase in the friction factor. Specifically, the new end wall design enhances average Nu by approximately 91.88%–103.04% and HTEI by 74.15%–78.05% over a Reynolds number range of Re=7400–36000. Six geometric parameters of the CTRE design were investigated, including the height, long-base length, and short-base length of the upstream and downstream ribs. The results provide valuable insights into the physical mechanisms associated with geometric variations.