Parham Rezaei

Parham Rezaei

Auto-generated profile, based on publicly available information

Parham Rezaei

Department of Mechanical Engineering, University of Maryland at College Park, College Park, MD, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Closed access
PDF file
PRParham Rezaei
Parham Rezaei
SLSang-Yoep Lee
Sang-Yoep Lee
KCkyujin Cho
kyujin Cho
JHJIN-OH HAHN
JIN-OH HAHN
Existing noninvasive breathing assist options compatible with out-of-hospital settings are limited and not appropriate to enable essential everyday activities, thereby deteriorating the quality of life. In our prior work, we developed the Exo-Abs, a novel wearable robotic platform for ubiquitous assistance of respiratory functions in patients with respiratory deficiency. This paper concerns the development of a model-based closed-loop control algorithm for the Exo-Abs to automate its breathing assistance. To facilitate model-based development of closed-loop control algorithms, we developed a control-oriented mathematical model of the Exo-Abs. Then, we developed a robust absolutely stabilizing gain-scheduled proportional-integral control algorithm for automating the breathing assistance with the Exo-Abs, by (i) solving a linear matrix inequality formulation of the Lyapunov stability condition against sector-bounded uncertainty and interindividual variability in the mechanics of the abdomen and the lungs and (ii) augmenting it with a heuristic yet effective gain scheduling algorithm. Using in silico evaluation based on realistic and plausible virtual patients, we demonstrated the efficacy and robustness of the automated breathing assistance of the Exo-Abs under a wide range of variability in spontaneous breathing and Exo-Abs efficiency: the absolutely stabilizing gain-scheduled proportional-integral control resulted in small exhalation trajectory tracking error (<30 ml) with smooth actuation, which was superior to (i) its proportional-integral control counterpart in tracking efficacy and to (ii) its proportional-integral-derivative control counterpart in chattering.

20 September 2024 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Closed access
PDF file
PRParham Rezaei
Parham Rezaei
JLJoshua L. Leibowitz
Joshua L. Leibowitz
BKBehzad KadkhodaeiElyaderani
Behzad KadkhodaeiElyaderani
YMYejin Moon
Yejin Moon
MAMorcos Awad
Morcos Awad
JHJIN-OH HAHN
JIN-OH HAHN
Circulation of perfluorocarbon (PFC) through corporeal cavities has received interest by virtue of its potential to supplement oxygenation via mechanical ventilation. However, the technology is not mature enough for clinical application, due to the knowledge gaps regarding the limiting factors hampering oxygen transport from PFC to blood. In this paper, we investigate a novel hypothesis that hypothermic peritoneal perfusion of cold oxygenated PFC may improve oxygenation of blood by facilitating the diffusion of oxygen from PFC to blood. Our hypothesis originates from physics-inspired insights that both hypothermia and PFC cooling may increase PFC-to-blood oxygen tension gradient: (i) hypothermia may decrease venous oxygen tension while (ii) cooling PFC may increase oxygen tension therein by increasing its oxygen solubility. Using a physics-based mathematical model capable of simulating oxygen tension responses to mechanical ventilation and peritoneal PFC perfusion under normothermic and hypothermic conditions, we analyzed the effect of hypothermic peritoneal cold PFC perfusion on blood oxygenation. The results predicted that peripheral oxygen saturation may be improved by 5–10% by peritoneal perfusion of oxygenated 15 °C PFC at 32 °C body temperature compared with peritoneal perfusion of oxygenated 37.5 °C PFC at 37.5 °C body temperature. The results also predicted that cooling PFC may play a more meaningful role than hypothermia. Pending the investigation of adverse impact of hypothermia and cold PFC on homeostasis, hypothermic cold PFC perfusion may improve peritoneal oxygenation by facilitating diffusion.

18 March 2026 in Physiological Measurement
Verified
Journal Article
Open access
PRParham Rezaei
Parham Rezaei
SSSina Masoumi Shahrbabak
Sina Masoumi Shahrbabak
JVJohn Vandenberge
John Vandenberge
YZYuanyuan Zhou
Yuanyuan Zhou
DTDemet Tangolar
Demet Tangolar
JHJIN-OH HAHN
JIN-OH HAHN
Objective: We investigated (i) if blood volume decompensation status (BVDS) can be trend-tracked by hemodynamic parameters, and (ii) if hemodynamic parameters capable of trend-tracking BVDS can be trend-tracked by the physio-markers derived from the physiological signals measured using wearable sensors. Approach: In 9 pigs undergoing controlled hemorrhage and blood transfusion, we measured gold standard arterial blood pressure (BP), heart rate (HR), stroke volume (SV), and cardiac output (CO) via invasive aortic BP and flow signals. In addition, we derived non-invasive physio-markers from the electrocardiogram (ECG), photoplethysmogram (PPG), and seismocardiogram (SCG) signals measured using wearable sensors. Then, we determined the best hemodynamic parameters to trend-track BVDS by comparing their correlation with BVDS. Finally, we investigated the feasibility of trend-tracking BVDS via non-invasive physio-markers in terms of their correlation with hemodynamic parameters as well as BVDS. Main Results: SV and CO could trend-track BVDS more consistently and explainably than BP and HR during hemorrhage and blood transfusion. The physio-markers of SV (the ratio between left ventricular ejection time (LVET) and pre-ejection period (PEP): LVET/PEP and PPG amplitude: APPG) and CO (HR·LVET/PEP and HR·APPG) showed close and monotonic relationships to SV (LVET/PEP: Spearman correlation 0.96 (0.93-0.98) and Pearson correlation 0.96 (0.93-0.98)) and CO (HR·LVET/PEP: Spearman correlation 0.95 (0.91-0.97) and Pearson correlation 0.91 (0.89-0.97)), and they likewise showed close and monotonic relationships to BVDS. However, substantial inter-individual variability in the hemodynamic parameters and their physio-markers was also observed. Significance: These findings suggest the feasibility of wearable-enabled hemodynamic monitoring during hemorrhage and blood transfusion, as well as the challenges therein.

9 December 2024 in IEEE Control Systems Letters
Verified
Journal Article
Closed access
PRParham Rezaei
Parham Rezaei
JFJoseph S. Friedberg
Joseph S. Friedberg
HFHosam K. Fathy
Hosam K. Fathy
JHJIN-OH HAHN
JIN-OH HAHN
Mixed venous oxygen saturation (SvO2) can play a pivotal role for patient monitoring and treatment in critical care and cardiopulmonary medicine. Unfortunately, its continuous measurement requires the use of invasive pulmonary artery catheters. This paper presents a novel population-informed personalized Gaussian sum extended Kalman filtering (PI-PGSEKF) approach to continuous SvO2 estimation from arterial oxygen saturation (SpO2) measurement. The main challenge in SvO2 estimation is large inter-individual variability in the cardiopulmonary dynamics, which seriously deteriorates the efficacy of standard EKF. To cope with this challenge, we employ the GSEKF in which individual EKFs are designed using a mathematical model of cardiopulmonary dynamics whose operating points are selected from (i) population-level generative sampling (thus “population-informed”) and (ii) Markov chain Monte Carlo (MCMC) sampling based on a one-time SpO2-SvO2 measurement (thus “personalized”). Using the experimental data collected from 8 hypoxia trials in 4 large animals, we showed the ability of the PI-P-GSEKF to estimate SvO2 from SpO2 in comparison with its PI-EKF (EKF with population-level generative sampling as the source of process noise) and PIGSEKF (GSEKF with population-level generative sampling alone) counterparts (average SvO2 root-mean-squared error: PI-EKF 4.7%, PI-GSEKF 4.3%, PI-P-GSEKF 3.0%). We also showed that population-level generative sampling and MCMC sampling both had respective roles in improving SvO2 estimation accuracy. In sum, the PI-P-GSEKF demonstrated its proof-of-principle to enable non-invasive continuous SvO2 estimation.

3 December 2025 in IEEE Control Systems Letters
Verified
Journal Article
Closed access
YKYi-Ming Kao
Yi-Ming Kao
PRParham Rezaei
Parham Rezaei
SSSina Masoumi Shahrbabak
Sina Masoumi Shahrbabak
JPJeremy Alanano Pepino
Jeremy Alanano Pepino
ISIan Sebastian Kirk Shogren
Ian Sebastian Kirk Shogren
JHJIN-OH HAHN
JIN-OH HAHN
Blood pressure (BP) management is a critical component of blood transfusion, but no mature technology capable of predicting BP response to blood transfusion exists. This paper concerns the development and preliminary in vivo testing of a BP prediction method applicable to hemorrhage and blood transfusion. Key obstacles are (i) large inter-individual variability in the BP response to blood transfusion, (ii) unknown hemorrhage, and (iii) input/state-dependent observability. To cope with these challenges, we developed a multi-modal sequential inference-enabled BP prediction method built upon a mathematical model of patient physiology parameterized by population-informed prior. The method infers patient-specific physiological state and hemorrhage, and uses them to predict future BP in a patient receiving blood transfusion. The in vivo testing of the method using the data collected from large animals undergoing hemorrhage and blood transfusion showed that it could adequately predict mean arterial BP with median absolute errors for 5-min and 15-min predictions of 3.1 mmHg and 7.4 mmHg as well as adequately infer physiological state and hemorrhage: all the hemorrhage events were detected with <3.5 min delay, with median F1 score of 85%. In sum, the prediction of BP response to blood transfusion may be feasible, even in the presence of unknown hemorrhage.

28 October 2025 in Journal of Dynamic Systems, Measurement, and Control
Verified
Journal Article
Open access
YZYuanyuan Zhou
Yuanyuan Zhou
SSSina Masoumi Shahrbabak
Sina Masoumi Shahrbabak
PRParham Rezaei
Parham Rezaei
RBRayan Bahrami
Rayan Bahrami
FRFarhan N. Rahman
Farhan N. Rahman
JHJIN-OH HAHN
JIN-OH HAHN
Cardiovascular arousal to acute mental stressors (AMSs) poses significant risks to health and contributes to cardiovascular and neurological disorders. Transcutaneous median nerve stimulation (TMNS) is an emerging noninvasive intervention with the potential to enable just-in-time mitigation of cardiovascular arousal to acute mental stressors. However, no prior work has addressed how to best control TMNS for this purpose. A critical limitation is the lack of basic knowledge of the dynamics between acute mental stressors and TMNS versus cardiovascular arousal. As an initial step toward investigating closed-loop controlled just-in-time TMNS for mitigating cardiovascular arousal to acute mental stressors, we developed and evaluated a data-driven virtual experiment generator (VEG) which can replicate the dynamics between acute mental stressors and TMNS versus cardiovascular arousal. In terms of a novel synthetic multimodal variable (SMV) intended to serve as feedback for just-in-time TMNS, we derived a fourth-order linear decoupled multi-input-single-output (MISO) representation to replicate the dynamics between acute mental stressors and TMNS as inputs versus SMV as output using data collected from 23 experiments. The representation could (i) replicate SMV responses in all experiments when parameterized with the experiment-specific parametric probability density functions (PDFs) and (ii) generate plausible virtual experiments when parameterized with the experiment-aggregated parametric PDFs. In sum, the VEG has the potential as a virtual platform to develop and evaluate closed-loop controlled just-in-time TMNS for mitigating acute mental stressor-induced cardiovascular arousal with SMV as feedback.