This paper presents a detailed experimental wavelength modulation spectroscopy approach and demonstrates its applicability to various types of semiconductor lasers in the near infrared and mid-infrared. A 5250 nm continuous-wave distributed feedback quantum cascade laser, a 2004 nm vertical cavity surface emitting laser, and a 1650 nm distributed feedback edge-emitting laser are used to extract the concentration and pressure values of nitric oxide, carbon dioxide, and methane, respectively, using the 2f wavelength modulation spectroscopy (WMS) technique under controlled conditions. The generality of the technique is demonstrated by extending it to 3f WMS for the three different kinds of lasers used in this study. The methodology required to provide in-situ real-time measurements of both gas parameters and operating characteristics of the laser are described in detail. Finally, the advantages and limitations of the technique are discussed in view of the fact that the characteristic behavior of the laser sources is significantly different. We specifically discuss the issue of targeting non-absorbing wavelength regions and the choice of modulation frequency and modulation amplitude of the laser, as well as the choice of the detection harmonic.
In this paper, the 2f/1f tunable diode laser wavelength modulation spectroscopy is used for the simultaneous measurement of concentration and temperature of CO 2 in the exhaust plume of an aero engine. The suitability of the R48 spectral feature of CO 2 at 1997.2 nm is discussed for this project and for further application of CO 2 tomographic imaging on large-scale aero-engines. To ensure accurate recovery of gas parameters at the high exhaust temperatures, a full spectral characterization of the absorption feature is presented using a direct spectroscopy. The 2f/1f method is validated in the laboratory for controlled gas mixtures and temperatures to recover concentration and temperature. Good agreement with the actual temperature and concentration values is demonstrated. Finally, single path measurements are presented for an aero engine exhaust showing good correlation with the measured engine conditions.
1 March 2017 in Flow Measurement and Instrumentation
A calibration-free 1f wavelength modulation spectroscopy (1f-WMS) technique for gas species parameter measurement is demonstrated. In this technique, the total magnitude of the first harmonic (1f) WMS signal is normalised by a component of the 1f residual amplitude modulation (1f-RAM) signal. This method preserves the advantages of traditional nf/1f-WMS (n×2) technique, such as immunity to the non-absorbing systematic losses and accurate recovery of gas parameters without the requirement for non-absorbing regions for normalisation at high pressure or high modulation index values (m-values). The proposed technique only requires the first harmonic signal, which has the largest magnitude of all the harmonics signals, and therefore fundamentally has a higher sensitivity to the nf/1f technique. Furthermore, since only the 1f-WMS signal is used the technique is less complex in terms of signal processing and data acquisition. The paper also shows a comparison of the proposed technique and 2f/1f for measuring CO $_{2}$ in the exhaust of a combuster. This data highlights how nonlinearities in the optical detection system as a function of frequency have a considerable effect on the recovered 2f/1f spectra causing variation in the recovered gas concentrations. This effect is not seen in the methodology proposed in this paper.
10 January 2022 in International Journal of Thermophysics
Accurate temperature measurements are critical in manufacturing, affecting both product quality and energy consumption. At elevated temperatures, non-contact thermometers are often the only option. However, such instruments require prior knowledge of the surface emissivity, which is often unknown or difficult to determine, leading to large errors. Here we present a novel imaging luminescence thermometer based on the intensity ratio technique using magnesium fluorogermanate phosphor, with the potential to overcome this limitation. We describe measurements performed on a number of engineering alloys undergoing heat treatment at temperatures of up to 750 °C and compare these measurements against a traditional contact thermocouple and thermal imager system. Agreement between the luminescence and embedded thermocouple temperatures was found to be better than 45 °C at all temperatures. However, the thermal imager measurement on the bare metal samples, with the instrument emissivity set to 1.0, showed differences of up to 500 °C at 750 °C, a factor of 10 larger. In an effort to improve the thermal imager accuracy, its instrument emissivity was adjusted until its temperature agreed with that of the thermocouple. When measuring on the bare metal, the effective emissivity was strongly sample dependent, with mean values ranging from 0.205 to 0.784. Since the phosphor derived temperatures exhibited substantially smaller errors compared to the thermal imager, it is suggested that this method can be used to compliment the thermal imaging technique, by providing a robust mechanism for adjustment of the instrument emissivity until agreement between the thermal imager and phosphor thermometer is obtained.
Intrapulse quantum cascade laser spectrometers are able to produce both saturation and molecular alignment of the gas sample. This is due to the rapid sweep of the radiation through the absorption features. The intrapulse time domain spectra closely resemble those recorded in coherent optical nutation experiments. In the present paper, the frequency down-chirped technique is employed to investigate the nitrous oxide–foreign gas collisions. We have demonstrated that the measurements may be characterized by the induced polarization dominated and collision dominated measurement limits. The first of these is directly related to the time dependence of the long range collision cross sections. Among the collisional partners considered, carbon dioxide shows a very unusual behavior of rapid polarization damping, resulting in the production of symmetrical line shapes at very low gas buffer pressures. In the collision dominated regime, the pressure broadening parameters, which we have derived, are comparable at slow chirp rates, with those derived from other experimental methods. By comparing the pressure broadening coefficients of Ar, , and with those of He, making use of the chirp rate independence of the pressure broadening by helium, we have shown that at higher chirp rates there is clear evidence of the chirp-rate dependence of the pressure broadening parameters of and .