We present an imaging phosphor thermometry system using the time-domain intensity ratio technique and demonstrate surface temperature measurements that are traceable to ITS-90 with a calibration Standard uncertainty of 0.5 °C, over the range 20 °C to 450 °C. The thermographic phosphor used was Mg 4 FGeO 6 :Mn. Typically, imaging phosphor thermometry systems make use of the intensity ratio of the phosphor emission in two discrete wavelength bands, measured simultaneously using two cameras viewing the same surface. However, difficulties can arise with image registration (the requirement to spatially align the two images) due to lens distortion, non-normal viewing angles and camera alignment, and this can result in large temperature errors. The time-domain intensity ratio technique presented here avoids these difficulties by capturing two images at different times during the phosphorescence decay process using a single monochrome camera. Each pixel of the camera integrates the light collected over the exposure time. By careful selection of an appropriate exposure time, along with the timing of each exposure (image gating), it is possible to collect two specific time integrated portions of the phosphor decay curve. The phosphor decay time can then be calculated quickly and uniquely from the ratio of these two signals and related to the temperature through calibration. With this technique, there is no requirement for high frame-rates and satisfactory results can be obtained using a relatively inexpensive camera provided that suitable triggering and exposure control are available. Here, we provide a description of the technique, the instrumentation, calibration, and preliminary measurement made on a resistively heated steel coupon, where the standard uncertainty for a single imaged pixel (80 μm × 80 μm) was 7.7 °C, 6.6 °C and 3.8 °C at temperatures of 200 °C, 300 °C and 400 °C respectively. Additionally, a sensitivity analysis and an uncertainty budget are provided.
10 January 2022 in International Journal of Thermophysics
Accurate temperature measurements are critical in manufacturing, affecting both product quality and energy consumption. At elevated temperatures, non-contact thermometers are often the only option. However, such instruments require prior knowledge of the surface emissivity, which is often unknown or difficult to determine, leading to large errors. Here we present a novel imaging luminescence thermometer based on the intensity ratio technique using magnesium fluorogermanate phosphor, with the potential to overcome this limitation. We describe measurements performed on a number of engineering alloys undergoing heat treatment at temperatures of up to 750 °C and compare these measurements against a traditional contact thermocouple and thermal imager system. Agreement between the luminescence and embedded thermocouple temperatures was found to be better than 45 °C at all temperatures. However, the thermal imager measurement on the bare metal samples, with the instrument emissivity set to 1.0, showed differences of up to 500 °C at 750 °C, a factor of 10 larger. In an effort to improve the thermal imager accuracy, its instrument emissivity was adjusted until its temperature agreed with that of the thermocouple. When measuring on the bare metal, the effective emissivity was strongly sample dependent, with mean values ranging from 0.205 to 0.784. Since the phosphor derived temperatures exhibited substantially smaller errors compared to the thermal imager, it is suggested that this method can be used to compliment the thermal imaging technique, by providing a robust mechanism for adjustment of the instrument emissivity until agreement between the thermal imager and phosphor thermometer is obtained.
6 November 2019 in International Journal of Thermophysics
Accurate measurement of post-flame temperatures can significantly improve combustion efficiency and reduce harmful emissions, for example, during the development phase of new internal combustion engines and gas turbine combustors. Non-perturbing optical diagnostic techniques are capable of measuring temperatures in such environments but are often technically complex and validation is challenging, with correspondingly large uncertainties, often as large as 2 % to 5 % of temperature. This work aims to reduce these uncertainties by developing a portable flame temperature standard, calibrated via the Rayleigh scattering thermometry technique, traceable to ITS-90, with an uncertainty of 0.5 % of temperature (k = 1). By suitable burner selection and accurate gas flow control, a stable, square, flat flame with uniform post-flame species and temperature is realised. Following development, the standard flame is used to validate two IR emission spectroscopy systems, both measuring the line-integrated emission spectra in the post-flame region. The first utilises a Hyperspectral imaging FTIR spectrometer capable of measuring 2D species and temperature maps and the second, a high-precision single line-of-sight FTIR spectrometer. In the central post-flame region, the agreement between the Rayleigh and FTIR temperatures is within the combined measurement uncertainties and amounts to 1 % (k = 1) of temperature.
29 January 2022 in International Journal of Thermophysics
Temperature measurement of stored nuclear waste is important for long-term monitoring. Conventional sensors can degrade in ionizing radiation from induced transmutations and their frequent replacement is inconvenient. A thermometer based on suitable phosphors can overcome some problems, but the optical signal needs to be transmitted through an optical fibre and processed remotely away from the dangerous area. This requires that the optical fibre itself be suitably resistant to radiation-induced damage. Here, we report transmission measurements through a type of hollow-core fibre based on anti-resonance and with transmission windows at wavelengths suitable for use with the thermographic phosphor magnesium fluorogermanate whilst subjected to gamma radiation. Its performance is compared to commercially available standard fibres (single mode and radiation hard fibres) at dose rates equivalent to decades of use in a storage facility. Transmission was unchanged for the anti-resonant fibre at the phosphor emission wavelength and it was successfully incorporated into a fibre thermometer that worked from $${20}\,^{\circ }\hbox {C}$$ to $$200\,^{\circ }\hbox {C}$$ . Performance at the phosphor excitation wavelength needs to be improved by modification to the hollow-core fibre design, but we show that a hybrid of single mode and anti-resonant fibres can already be made into a thermometer with suitable gamma immunity.
11 June 2019 in Progress in Photovoltaics: Research and Applications
Accurate temperature measurements of a photovoltaic (PV) device are not always straightforward. Compromises between accuracy and spatial resolution often have to be made to give either quantitative single point measurements or qualitative spatial measurements. Phosphor thermometry is demonstrated in this work to measure the temperature of an encapsulated silicon photovoltaic device with uncertainty less than 1 °C. Comparisons with contact thermocouple probes are made under external white‐light illumination and internal resistive heating. Under similar conditions, phosphor thermal imaging shows less sensitivity to sources of uncertainty such as poor probe positioning and reduced thermal contact, allowing the detection of faults and shunt induced thermal hot spots in encapsulated PV devices with a higher degree of confidence.
In preparation for the new challenges posed by the higher temperature environments which are likely to be encountered in the next generation of nuclear power plants, to maintain the safety and to ensure the long-term reliability of such plants, it is crucial that new temperature sensors and methods for in-situ measurement are investigated and developed. This is the general objective of the first workpackage of the joint research project, ENG08 MetroFission, funded in the framework of the European metrology research program. This paper will review the results obtained in developing and testing new temperature sensors and references during the course of the project. The possible continuation of these activities in the future is discussed.