11 October 2019 in Journal of Biomedical Optics
Riboflavin and UV-induced corneal collagen crosslinking (CXL) has been well-recognized as an effective treatment for progressive keratoconus.1 The main step of CXL is a photochemical reaction between the riboflavin photosensitizer and UV light. This reaction strengthens the biomechanical properties of the cornea by increasing the covalent bonding in the stroma.2 The widely used standard Dresden solution requires a 30-min infiltration of riboflavin solutions followed by 30 min of UV irradiation (, ).3 However, it is difficult for some patients, for example, children and patients with Down syndrome (a disease highly associated with keratoconus),4 to keep themselves focused on the target over a 30-min treatment. According to the Bunsen–Roscoe law, the same effect can be achieved theoretically with an equal radiant energy provided by less intense UV radiation over a longer period of time or a more intense UV radiation over a shorter period of time.5 This means the time of treatment could be shortened by increasing the irradiance within a safe range. However, several in vitro studies have found a decrease in the efficacy of accelerated CXL treatments due to oxygen depletion in the photochemical reaction. Although accelerated CXL treatments have shown promise in the clinic, an appropriate evaluation technique is necessary to find the balance between the time-consumption of CXL procedures and the efficiency.
18 October 2019 in Journal of Biophotonics
5 May 2020 in Journal of Biophotonics
29 November 2022 in Biomedical Optics Express
Lens biomechanics has great potential for application in clinical diagnostics and treatment monitoring of presbyopia and cataracts. However, current approaches to lens elastography do not meet the desired safety or sensitivity for clinical application. In this regard, we propose a noncontact optical coherence elastography (OCE) method to facilitate quantitative in situ imaging of lens elasticity. Elastic waves induced by air-pulse stimulation on the limbus propagate to the lens and are then imaged using custom-built swept-source optical coherence tomography to obtain the elastic wave velocity and Young’s modulus. The proposed OCE method was first validated by comparing the results of in situ and in vitro measurements of porcine lenses. The results demonstrate that the Young’s modulus measured in
situ was highly consistent with that measured in
vitro and had an intraclass correlation coefficient of 0.988. We further investigated the elastic changes induced by cold storage and microwave heating. During 36-hour cold storage, the mean Young’s modulus gradually increased (from 5.62 ± 1.24 kPa to 11.40 ± 2.68 kPa, P < 0.0001, n = 9) along with the formation of nuclear opacities. 15-second microwave heating caused a greater increase in the mean Young’s modulus (from 6.86 ± 1.21 kPa to 25.96 ± 8.64 kPa, P < 0.0025, n = 6) without apparent cataract formation. Accordingly, this study reports the first air-pulse OCE measurements of in situ lenses, which quantified the loss of lens elasticity during simulated cataract development with good repeatability and sensitivity, thus enhancing the potential for adoption of lens biomechanics in the clinic.
29 May 2021 in Journal of Biophotonics
2 June 2020 in Eye and Vision
Background: To quantitatively assess anterior chamber angle (ACA) structure by anterior segment optical coherence tomography (AS-OCT) and develop a model to evaluate angle width as defined by gonioscopy.Methods: The ACAs of each quadrant were evaluated by gonioscopy, classified by the Scheie grading system, and assigned into one of the three grades: small angle (SA), moderate angle (MA), and large angle (LA). The eyes were imaged by AS-OCT, and ACA structural parameters including angle opening distance at the scleral spur (AODSS) and at 750 μm anterior to the scleral spur (AOD750), trabecular-iris space area at 750 μm anterior to the scleral spur (TISA750), and a newly defined parameter “light intersection distance” (LID), were measured. The ACA structural data were used to construct an ordered logistic regression model for assignment of ACAs to one of the three angle grades. The validity of the model was then tested.Results: A total of 169 quadrants from 53 subjects were included in the analysis, of which 111 quadrants were included in the modeling data and 58 in the testing data. In pairwise comparisons of SA, MA, and LA by ANOVA, the measured parameters were as follows: AOD750 (0.174 ± 0.060 vs. 0.249 ± 0.068 vs. 0.376 ± 0.114 mm;P < 0.001), TISA750 (0.075 ± 0.035 vs. 0.117 ± 0.036 vs. 0.181 ± 0.062 mm2;P < 0.001), and LID (− 0.300 ± 0.187 vs. -0.085 ± 0.170 vs. 0.122 ± 0.156 mm;P < 0.001). The ACA grading model based on LID showed a relatively high correction rate of 72.4%, and the model efficiency, calculated using the receiver operating characteristic, showed an area under the curve of 0.740. Weighted kappa statistics showed a good agreement for multiple ACA grades (0.772).Conclusions: The AS-OCT-based multiple ACA grades model was demonstrated as a non-contact approach for ACA assessment with high speed and high spatial resolution, providing guidance for diagnosis of angle closure.