Yulei Chen

Dr. Yulei Chen

Dongguan Tungwah Hospital, Dongguan, Guangdong, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2022 in Biomedical Optics Express
Verified
Journal Article
Closed access
Yulei ChenYulei Chen
Yulei Chen
SYShuling Ye
Shuling Ye
QWQingying Wang
Qingying Wang
MSMeixiao Shen
Meixiao Shen
FLFan Lu
Fan Lu
DZDexi Zhu
Dexi Zhu
Lens biomechanics has great potential for application in clinical diagnostics and treatment monitoring of presbyopia and cataracts. However, current approaches to lens elastography do not meet the desired safety or sensitivity for clinical application. In this regard, we propose a noncontact optical coherence elastography (OCE) method to facilitate quantitative in situ imaging of lens elasticity. Elastic waves induced by air-pulse stimulation on the limbus propagate to the lens and are then imaged using custom-built swept-source optical coherence tomography to obtain the elastic wave velocity and Young’s modulus. The proposed OCE method was first validated by comparing the results of in situ and in vitro measurements of porcine lenses. The results demonstrate that the Young’s modulus measured in situ was highly consistent with that measured in vitro and had an intraclass correlation coefficient of 0.988. We further investigated the elastic changes induced by cold storage and microwave heating. During 36-hour cold storage, the mean Young’s modulus gradually increased (from 5.62 ± 1.24 kPa to 11.40 ± 2.68 kPa, P < 0.0001, n = 9) along with the formation of nuclear opacities. 15-second microwave heating caused a greater increase in the mean Young’s modulus (from 6.86 ± 1.21 kPa to 25.96 ± 8.64 kPa, P < 0.0025, n = 6) without apparent cataract formation. Accordingly, this study reports the first air-pulse OCE measurements of in situ lenses, which quantified the loss of lens elasticity during simulated cataract development with good repeatability and sensitivity, thus enhancing the potential for adoption of lens biomechanics in the clinic.

29 May 2021 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
SYShuling Ye
Shuling Ye
YZYuheng Zhou
Yuheng Zhou
CBChenhong Bao
Chenhong Bao
Yulei ChenYulei Chen
Yulei Chen
FLFan Lu
Fan Lu
DZDexi Zhu
Dexi Zhu

22 March 2024 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
JWJiefang Wang
Jiefang Wang
XLXinting Liu
Xinting Liu
JHJing Huang
Jing Huang
RDRuoyun Deng
Ruoyun Deng
SZSijun Zhao
Sijun Zhao
XMXinjie Mao
Xinjie Mao
Purpose: To investigate the contrast sensitivity function (CSF) changes in simple high myopia (SHM) and evaluate the correlations between these changes with the early changes in the retinal microstructure.Methods: This prospective study comprised 81 subjects, 20 with emmetropia (EM), 26 with low myopia and moderate myopia (LM/MM), and 35 with SHM. The area under the log CSF curve (AULCSF) and the cut-off spatial frequency (Cut-off SF) were employed as measures of CSF. Adaptive optics (AO) was employed to quantify the cone density, spacing, and regularity. The thickness and blood flow of the retinal sublayers were determined from vertical and horizontal optical coherence tomography angiography (OCTA) A-scans. Swept-source optical coherence tomography (SS-OCT) was employed to analyze the choroidal thickness (CT) and choroidal vascularity using a custom algorithm. Differences in the retinal and choroidal parameters, cone distribution, AULCSF, and Cut-off SF were compared among the three groups. Multivariate linear mixed models were used to elucidate the associations between photoreceptor morphological alterations, retinal and choroidal parameters, and AULCSF.Results: The AULCSF and Cut-off SF were significantly lower in the SHM group compared to the EM and LM groups (p < 0.05). The SHM group had less cone density, larger cone spacing, and lower cone regularity than the EM and LM/MM groups (p < 0.05). Moreover, the thickness of the inner segment of photoreceptors (IS), retinal pigment epithelium (RPE) layer and choroid were reduced, and the outer segment of photoreceptors (OS) was thicker in the SHM group compared to the EM and LM/MM groups (all p < 0.05). A longer axial length (AL) was correlated with decreased AULCSF, cone density, and cone spacing (r = −0.800 to 0.752, all p < 0.050). Additionally, decreased CSF was correlated with lower cone density (r = 0.338, p = 0.035).Conclusion: Decreased contrast sensitivity was observed in patients with SHM and cone density was significantly correlated with reduced AUCSF.

7 March 2024 in Journal of Biophotonics
Verified
Journal Article
Closed access
QWQingying Wang
Qingying Wang
Yulei ChenYulei Chen
Yulei Chen
KSKexin Shen
Kexin Shen
XZXingyu Zhou
Xingyu Zhou
MSMeixiao Shen
Meixiao Shen
DZDexi Zhu
Dexi Zhu

6 November 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
TXTing Xie
Ting Xie
WLWangting Li
Wangting Li
LWLinli Wang
Linli Wang
JNJiafeng Ning
Jiafeng Ning
ZLZhi Li
Zhi Li
QCQingshan Chen
Qingshan Chen
Purpose: To assess the safe, lowest effective laser power of subthreshold micropulse laser (SML) for treating acute and chronic central serous chorioretinopathy (CSC) in Chinese patients.Methods: Patients were distinguished with acute or chronic CSC based on focal or diffuse retinal pigment epithelium (RPE) leakage on fundus fluorescein angiography (FFA), with or without widespread RPE decompensation. Patients were categorized into five groups and treated with 577 nm yellow SML according to 50% titration power. The change of best-corrected visual acuity (BCVA) and central macular thickness (CMT) were set as primary outcomes. A linear regression model assessed the correlation between different factors and outcome indicators.Results: A total of 103 patients with 127 eyes (61 with acute CSC and 66 with chronic CSC) were enrolled. The baseline characteristics were balanced between the five groups (all p > 0.05). The decrease of CMT and the improvement of BCVA were related to the CMT at baseline (all p < 0.05). We found that the lowest effective laser power for acute CSC was 425 mW (−225.50 μm vs. −171.24 μm vs. −114.50 μm vs. −130.54 μm vs. −68.00 μm, p < 0.001), showing a significant CMT reduction at this power, but no significant increase in BCVA (−0.15 ± 0.10 logMAR vs. −0.20 ± 0.16 logMAR vs. −0.14 ± 0.11 logMAR vs. −0.17 ± 0.30 logMAR vs. −0.11 ± 0.14 logMAR, p > 0.05). For chronic CSC, the lowest effective laser power was 375 mW (p = 0.01), the change of CMT was significant in 375 mW (−93.91 ± 109.06 μm, −119.32 ± 105.56 μm, −88.67 ± 67.26 μm, −60.89 ± 106.86 μm, and −99.11 ± 157.32 μm, p = 0.04). The change of BCVA was similar trend (−0.54 ± 0.66 logMAR vs. −0.17 ± 0.23 logMAR vs. −0.10 ± 0.21 logMAR vs. −0.02 ± 0.30 logMAR vs. 0.05 ± 0.19 logMAR, p < 0.001).Conclusion: In this study, our results suggested 425 mW and 375 mW laser power is the lowest effective SML power for treating acute and chronic CSC in Chinese patients respectively, And the power of SML for chronic CSC requires lower power than acute CSC.

24 October 2024 in Frontiers in Medicine
Verified
Journal Article
Open access
PDF file
Yulei ChenYulei Chen
Yulei Chen
HXHaoxiong Xian
Haoxiong Xian
MLMinghui Liu
Minghui Liu
XDXiuqing Dong
Xiuqing Dong
SDShaolin Du
Shaolin Du
Purpose: To characterize the regional variations of choroidal vascularity index (CVI) in patients with diabetes mellitus (DM) using ultra-wide-field optical coherence tomography angiography (UWF-OCTA) and identify their correlations with the onset of diabetic retinopathy (DR).Methods: This cross-sectional, monocular-sampling study recruited 141 participants from four age-matched groups: no DM (NDM), no DR with early DM (EDM) and late DM (LDM), and mild–moderate non-proliferative diabetic retinopathy (mNPDR). UWF-OCTA was employed for circular scans centered on the fovea. CVI in the central region (0–1 mm) and four quadrants of the concentric rings with different ranges (1–3, 3–6, 6–9, 9–12, 12–15, 15–18 mm) was obtained for analysis together with their demographic and clinical data. The Area under the receiver operating characteristic curve (AUC) was calculated to assess the diagnostic efficacy for mNPDR and compared using the DeLong test.Results: The average CVI was lower in patients with mNPDR compared to other groups across all regions. Although there was no significant difference in DM duration between the LDM and mNPDR groups, a notable variance in CVI was observed, particularly (p = 0.0004) in the temporal quadrant of the 15–18 mm range (T18). CVI in T18 region was negatively correlated with creatinine levels, while positively correlated with body mass index and estimated glomerular filtration rate (ps < 0.05). The CVI in the T18 region demonstrated superior diagnostic efficacy (AUC = 0.755), and when combined with those in other regions and clinical data, the AUC rose to 0.907, which was significantly better (p = 0.0280) than using clinical data alone.Conclusion: Reduced CVI was observed in the most peripheral region, highly predictive for mNPDR and associated with the declining renal function, thus enhancing the potential of UWF-OCTA to integrate into DM management and promote early DR screening.