Paula Immonen

Paula Immonen

Auto-generated profile, based on publicly available information

Paula Immonen

Lappeenranta University of Technology, Lappeenranta, Finland

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2016 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TLTutkijaopettaja Pia Lindh
Tutkijaopettaja Pia Lindh
MTMohammad Gerami Tehrani
Mohammad Gerami Tehrani
TLTuomo Lindh
Tuomo Lindh
JMJan-Henri Montonen
Jan-Henri Montonen
JPJuha Pyrhonen
Juha Pyrhonen
MPMaria Polikarpova
Maria Polikarpova
An electrical and mechanical design process for a traction motor in a hybrid bus application is studied. Usually, the design process of an electric machine calls for close cooperation between various engineering disciplines. Compromises may be required to satisfy the boundary conditions of electrical, thermal, and mechanical performances. From the mechanical point of view, the stress values and the safety factors should be at a reasonable level and the construction lifetime predicted by a fatigue analysis. In a vehicle application, the motor has to be capable of generating high torque when accelerating, and in normal operation, the losses of the machine should be low to be able to cool the machine. Minimization of the no-load iron losses becomes a very important electrical design requirement if the traction motor and the generator are mechanically connected with an internal combustion engine when it is operating as the only source of torque. The manufacturing costs of the motor are also taken into account in this paper.

1 April 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
TLTutkijaopettaja Pia Lindh
Tutkijaopettaja Pia Lindh
IPIlya Petrov
Ilya Petrov
JPJuha Pyrhonen
Juha Pyrhonen
ESEero Scherman
Eero Scherman
MNMarkku Niemelä
Markku Niemelä
PIPaula Immonen
Paula Immonen
Direct liquid cooling (DLC) of electrical machine windings is a clearly effectual cooling method for high-torque and high-power-density applications needed, especially, in heavy vehicles. Usually, in electric vehicles, the stator copper winding losses are the most dominating losses during the accelerating or decelerating (recuperation) modes, and therefore, traditional windings may heat up significantly during high-torque periods. Removing the heat directly from the winding in which most of the heat is generated, allows the most straightforward and effective way of cooling. This paper investigates the feasibility of the direct liquid cooling in a radial-flux permanent-magnet traction motor. This case provides experimental information of the behavior of the direct liquid cooling of the windings. The prototype motor equipped with directly liquid-cooled windings is installed in an electric bus so that typical bus load cycles can be tested.

11 December 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HMHenri Montonen
Henri Montonen
NNNiko Nevaranta
Niko Nevaranta
TLTuomo Lindh
Tuomo Lindh
JAJani Alho
Jani Alho
PIPaula Immonen
Paula Immonen
OPOlli Pyrhonen
Olli Pyrhonen
Driveline resonances are one of the major reasons for poor vehicle drivability, passenger discomfort, and premature wear of the mechanical parts of the driveline. Therefore, adequate models generated by system identification are essential in order to analyze resonances, and especially to design solutions to mitigate these adverse effects by means of control. In this paper, the resonating mechanical driveline of a hybrid city bus is identified by feeding different excitation signals, such as a pseudo-random binary signal, stepped sine, and chirp to the driveline, and by measuring the frequency response at a standstill and during on-road experiments. The identification experiments are conducted by operating the bus in the series electric hybrid mode, that is, in an operating mode that corresponds to a full electric mode powered by energy storages. Resonating two-mass system models are parametrized based on the obtained frequency responses and used to validate the identification experiments.

1 November 2021 in Renewable Energy
Verified
Journal Article
Open access
JKJere Knuutinen
Jere Knuutinen
HBHerman Böök
Herman Böök
VRVesa Ruuskanen
Vesa Ruuskanen
AKAntti Kosonen
Antti Kosonen
PIPaula Immonen
Paula Immonen
JAJero Ahola
Jero Ahola

1 December 2014 in IET Electrical Systems in Transportation
Verified
Journal Article
Open access
PDF file
PPPavel Ponomarev
Pavel Ponomarev
RÅRafael Åman
Rafael Åman
HHHeikki Handroos
Heikki Handroos
PIPaula Immonen
Paula Immonen
JPJuha Pyrhönen
Juha Pyrhönen
LLLasse Laurila
Lasse Laurila
Novel high power density integrated electro‐hydraulic machine for electrical hybrid working vehicles is presented. The machine is dedicated to be used as a mechanical power source for hydraulic actuators with possibility of electrical energy recuperation. Advantages of using such a machine in mobile environments are discussed. The efficiency of the device is studied and compared with the traditional valve controlled systems.

20 August 2013 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TLTutkijaopettaja Pia Lindh
Tutkijaopettaja Pia Lindh
JMJuho Montonen
Juho Montonen
PIPaula Immonen
Paula Immonen
JTJuan A. Tapia
Juan A. Tapia
JPJuha Pyrhonen
Juha Pyrhonen
Traction motor design significantly differs from industrial machine design. The starting point is the load cycle instead of the steady-state rated operation point. The speed of the motor varies from zero to very high speeds. At low speeds, heavy overloading is used for starting, and the field-weakening region also plays an important role. Finding a suitable field-weakening point is one of the important design targets. At the lowest speeds, a high torque output is desired, and all current reserves of the supplying converter unit are used to achieve the torque. In this paper, a 110-kW 2.5-p.u. starting torque and a maximum 2.5-p.u. speed permanent-magnet traction motor will be studied. The field-weakening point is altered by varying the number of winding turns of machine. One design is selected for prototyping. Theoretical results are verified by measurements.