The influence of slot-and-pole-number combinations on the leakage inductance of double-layer fractional-slot concentrated nonoverlapping winding (i.e., tooth-coil winding) permanent-magnet synchronous machines is studied. A Fourier-analysis-based method for calculating the harmonic air-gap leakage inductance applied to the current-linkage waveform (winding function) in the air gap is suggested. Different slot-and-pole combinations are considered, and their influence, in particular, on the air-gap leakage inductance is indicated. In tooth-coil machines, the air-gap harmonic leakage can have a surprisingly large impact on the machine performance.
6 August 2015 in IEEE Transactions on Industrial Electronics
Thermal properties are a key issue in many applications associated with electrical machines. Because of its special configuration, an axial-flux electrical machine usually uses self-ventilation. However, this cooling method has a significant impact degrading the machine operating characteristics, and thus, an independent cooling system is desirable. The focus of this paper is on the steady-state thermal modeling and laboratory testing of an axial-flux permanent-magnet (AFPM) electrical machine intended for a traction application. The proposed hybrid cooling arrangement consists of a frame cooling circuit with a water flow inside, a set of copper bars inserted in the teeth, and a segment of potting material around the end windings. Computational fluid dynamics and finite-element analysis are applied for the preliminary design. This paper provides experimental verification of the simulation results on a 100-kW AFPM electrical machine.
Analytical calculation methods for all the major components of the synchronous inductance of tooth-coil permanent-magnet synchronous machines are reevaluated in this paper. The inductance estimation is different in the tooth-coil machine compared with the one in the traditional rotating field winding machine. The accuracy of the analytical torque calculation highly depends on the estimated synchronous inductance. Despite powerful finite element method (FEM) tools, an accurate and fast analytical method is required at an early design stage to find an initial machine design structure with the desired performance. The results of the analytical inductance calculation are verified and assessed in terms of accuracy with the FEM simulation results and with the prototype measurement results.
A high demand for electrification of the transport sector has resulted in a need to provide compact and reliable electric power trains where the electric machine is a key element. The cooling system has a strong impact on the specific torque and power capability of the machine. The selection of the cooling solution should not be based on the steady-state cooling performance only but also on the transient characteristics owing to the typical operational load nature of the propulsion system, where the load is not continuous (as it usually is in industrial applications), but it frequently varies in time depending on the vehicle type and the driving style. This article investigates in detail the cooling capabilities of a direct winding liquid cooling solution and compares it with a traditional frame liquid cooling arrangement in the transient condition. As a result of the comparison, it was found that the location of heat removal close to the heat source makes the temperature transient time faster, which allows to apply overload operating points more frequently.