Marcel J. Rost

Marcel J. Rost

Auto-generated profile, based on publicly available information

Marcel J. Rost

Huygens-Kamerlingh Onnes Laboratory Leiden University Niels Bohrweg 2 2333 CA Leiden The Netherlands

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2005 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MRM. J. Rost
M. J. Rost
LCL. Crama
L. Crama
PSP. Schakel
P. Schakel
ETE. van Tol
E. van Tol
GVG. B. E. M. van Velzen-Williams
G. B. E. M. van Velzen-Williams
JFJ. W. M. Frenken
J. W. M. Frenken
In this article we introduce a, video-rate, control system that can be used with any type of scanning probe microscope, and that allows frame rates up to 200images∕s. These electronics are capable of measuring in a fast, completely analog mode as well as in the more conventional digital mode. The latter allows measurements at low speeds and options, such as, e.g., atom manipulation, current–voltage spectroscopy, or force–distance curves. For scanning tunneling microscope (STM) application we implemented a hybrid mode between the well-known constant-height and constant-current modes. This hybrid mode not only increases the maximum speed at which the surface can be imaged, but also improves the resolution at lower speeds. Acceptable image quality at high speeds could only be obtained by pushing the performance of each individual part of the electronics to its limit: we developed a preamplifier with a bandwidth of 600kHz, a feedback electronics with a bandwidth of 1MHz, a home-built bus structure for the fast data transfer, fast analog to digital converters, and low-noise drivers. Future improvements and extensions to the control electronics can be realized easily and quickly, because of its open architecture with its modular plug-in units. In the second part of this article we show our high-speed results. The ultrahigh vacuum application of these control electronics on our (UHV)-STM enabled imaging speeds up to 0.3mm∕s, while still obtaining atomic step resolution. At high frame rates, the images suffered from noticeable distortions, which we have been able to analyze by virtue of the unique access to the error (dZ) signal. The distortions have all been associated with mechanical resonances in the scan head of the UHV-STM. In order to reduce such resonance effects, we have designed and built a scan head with high resonance frequencies (⩾64kHz), especially for the purpose of testing the fast electronics. Using this scanner we have reached video-rate imaging speeds up to 200frames∕s (5ms∕image), while still obtaining atomically resolved structures.

1 January 2008 in Materials Today
Verified
Journal Article
Open access
GSGeorg Schitter
Georg Schitter
MRMarcel J. Rost
Marcel J. Rost

1 March 2009 in Asian Journal of Control
Verified
Journal Article
Closed access
PDF file
MRM. J. Rost
M. J. Rost
GBG. J. C. van Baarle
G. J. C. van Baarle
AKA. J. Katan
A. J. Katan
WSW. M. van Spengen
W. M. van Spengen
PSP. Schakel
P. Schakel
JFJ. W. M. Frenken
J. W. M. Frenken

10 March 2015 in Nature Communications
Verified
Journal Article
Open access
PDF file
GVG.J. Verbiest
G.J. Verbiest
MRM.J. Rost
M.J. Rost
Heterodyne detection schemes are widely used to detect and analyse high-frequency signals, which are unmeasurable with conventional techniques. It is the general conception that the heterodyne signal is generated only by mixing and that beating can be fully neglected, as it is a linear effect that, therefore, cannot produce a heterodyne signal. Deriving a general analytical theory, we show, in contrast, that both beating and mixing are crucial to explain the heterodyne signal generation. Beating even dominates the heterodyne signal, if the nonlinearity of the mixing element (mixer) is of higher order than quadratic. The specific characteristic of the mixer determines its sensitivity for beating. We confirm our results with both a full numerical simulation and an experiment using heterodyne force microscopy, which represents a model system with a highly non-quadratic mixer. As quadratic mixers are the exception, many results of previously reported heterodyne measurements may need to be reconsidered.

23 January 2013 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
YYYuriy I. Yanson
Yuriy I. Yanson
MRMarcel J. Rost
Marcel J. Rost

18 February 2016 in Nature Communications
Verified
Journal Article
Open access
ASAmirmehdi Saedi
Amirmehdi Saedi
MRMarcel J. Rost
Marcel J. Rost
Vapour deposition on polycrystalline films can lead to extremely high levels of compressive stress, exceeding even the yield strength of the films. A significant part of this stress has a reversible nature: it disappears when the deposition is stopped and re-emerges on resumption. Although the debate on the underlying mechanism still continues, insertion of atoms into grain boundaries seems to be the most likely one. However, the required driving force has not been identified. To address the problem we analyse, here, the entire film system using thermodynamic arguments. We find that the observed, tremendous stress levels can be explained by the flux-induced entropic effects in the extremely dilute adatom gas on the surface. Our analysis justifies any adatom incorporation model, as it delivers the underlying thermodynamic driving force. Counterintuitively, we also show that the stress levels decrease, if the barrier(s) for adatoms to reach the grain boundaries are decreased.