Zhipeng Tian

Zhipeng Tian

Auto-generated profile, based on publicly available information

Zhipeng Tian

Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei, Anhui, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZTZhipeng Tian
Zhipeng Tian
SLSiyuan Lou
Siyuan Lou
AWAng Wu
Ang Wu
MLMr. Lu
Mr. Lu
LYLu Yuan
Lu Yuan
JDJingtao Dong
Jingtao Dong
Stabilizing orthogonal phase bias is highly required in Mach-Zehnder interferometer (MZI) to achieve sufficiently high sensitivity and long-term stability. To this end, we demonstrated a stabilized MZI using dual-wavelength feedback and a geometric phase shifter (GPS). The two beams at the wavelengths of 632.8 nm and 532 nm, respectively, propagate almost in the common path in the MZI, so that the beams have the same sensitivity to ambient disturbance. The beam at 632.8 nm is used to sense the displacement, and the other one at 532 nm is used for feedback and orthogonal phase bias stabilization. The phase shift error of the two separate wavelengths can be compensated by a GPS consisting of a rotating half waveplate sandwiched between two static quarter waveplates. The results of the proof-of-concept experiment showed that the phase shift error between 632.8 nm and 532 nm was reduced to within (-0.08π, 0.09π) by the GPS, and can be further reduced by two orders of magnitude if more appropriate wavelengths or waveplates were selected. The stabilized MZI showed a displacement resolution of 5 nm, and was proved to be effective in suppressing the low-frequency noise less than 10 Hz.

1 August 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
JDJingtao Dong
Jingtao Dong
LXLiyuan Xie
Liyuan Xie
SWShuo Wang
Shuo Wang
EZEnxi Zhao
Enxi Zhao
YLYangyang Li
Yangyang Li
ZTZhipeng Tian
Zhipeng Tian
The dynamic measurement of surface deformation with an axisymmetric profile at nanometer- to micrometer-scale is of great interest in understanding micromechanical and thermophysical dynamics. We propose a carrier optical vortex interferometer (COVI) to measure such surface deformation dynamically by segmentation demodulation of the petal-like interferogram that is produced by the coaxial superposition of conjugated p-radial order Laguerre–Gaussian beams. Specifically, a rotating chopper placed at the exit of the interferometer introduces a carrier frequency in the absence of surface deformation. A camera placed behind the chopper uses a multi-ring segmentation detection scheme to produce a Doppler shift relative to the carrier frequency at the radius of each ring in the presence of axisymmetric surface deformation. Locating the Doppler shifts gives the surface deformation velocities at those radii. Thus, the dynamic surface deformation profile can be obtained by integrating the velocities over time. We reveal the basic principles of the carrier frequency and the Doppler shifts in the COVI theoretically. As a proof-of-concept, an external force-induced axisymmetric mechanical surface deformation is measured dynamically to demonstrate the validity of the COVI. The results show that the measurement error of the surface deformation velocity is within (−2.1, 1.1 nm/s) for the velocity ranging from 20 to 86 nm/s. The lower limit of the measurable velocity can reach 20 nm/s. The measurement error of the surface deformation profile is less than 2.5 nm for the amplitude of the surface deformation of 500 nm.