Stabilizing orthogonal phase bias is highly required in Mach-Zehnder interferometer (MZI) to achieve sufficiently high sensitivity and long-term stability. To this end, we demonstrated a stabilized MZI using dual-wavelength feedback and a geometric phase shifter (GPS). The two beams at the wavelengths of 632.8 nm and 532 nm, respectively, propagate almost in the common path in the MZI, so that the beams have the same sensitivity to ambient disturbance. The beam at 632.8 nm is used to sense the displacement, and the other one at 532 nm is used for feedback and orthogonal phase bias stabilization. The phase shift error of the two separate wavelengths can be compensated by a GPS consisting of a rotating half waveplate sandwiched between two static quarter waveplates. The results of the proof-of-concept experiment showed that the phase shift error between 632.8 nm and 532 nm was reduced to within (-0.08π, 0.09π) by the GPS, and can be further reduced by two orders of magnitude if more appropriate wavelengths or waveplates were selected. The stabilized MZI showed a displacement resolution of 5 nm, and was proved to be effective in suppressing the low-frequency noise less than 10 Hz.