The dataset presents a 43 year-long reanalysis of pollen seasons for three major allergenic genera of trees in Europe: alder (Alnus), birch (Betula), and olive (Olea). Driven by the meteorological reanalysis ERA5, the atmospheric composition model SILAM predicted the flowering period and calculated the Europe-wide dispersion pattern of pollen for the years 1980–2022. The model applied an extended 4-dimensional variational data assimilation of in-situ observations of aerobiological networks in 34 European countries to reproduce the inter-annual variability and trends of pollen production and distribution. The control variable of the assimilation procedure was the total pollen release during each flowering season, implemented as an annual correction factor to the mean pollen production. The dataset was designed as an input to studies on climate-induced and anthropogenically driven changes in the European vegetation, biodiversity monitoring, bioaerosol modelling and assessment, as well as, in combination with intra-seasonal observations, for health-related applications.
28 October 2024 in Geoscientific Model Development
A multiscale modeling ensemble chain has been assembled as a first step towards an air quality analysis and forecasting (AQF) system for Latin America. Two global and three regional models were tested and compared in retrospective mode over a shared domain (120–28° W, 60° S–30° N) for the months of January and July 2015. The objective of this experiment was to understand their performance and characterize their errors. Observations from local air quality monitoring networks in Colombia, Chile, Brazil, Mexico, Ecuador and Peru were used for model evaluation. The models generally agreed with observations in large cities such as Mexico City and São Paulo, whereas representing smaller urban areas, such as Bogotá and Santiago, was more challenging. For instance, in Santiago during wintertime, the simulations showed large discrepancies with observations. No single model demonstrated superior performance over others or among pollutants and sites available. In general, ozone and NO 2 exhibited the lowest bias and errors, especially in São Paulo and Mexico City. For SO 2 , the bias and error were close to 200 %, except for Bogotá. The ensemble, created from the median value of all models, was evaluated as well. In some cases, the ensemble outperformed the individual models and mitigated extreme over- or underestimation. However, more research is needed before concluding that the ensemble is the path for an AQF system in Latin America. This study identified certain limitations in the models and global emission inventories, which should be addressed with the involvement and experience of local researchers.
11 August 2020 in Atmospheric Chemistry and Physics
We have developed an integrated assessment tool that can be used for evaluating the public health costs caused by the concentrations of fine particulate matter (PM 2.5 ) in ambient air. The model can be used to assess the impacts of various alternative air quality abatement measures, policies and strategies. The model has been applied to evaluate the costs of the domestic emissions that influence the concentrations of PM 2.5 in Finland in 2015. The model includes the impacts on human health; however, it does not address the impacts on climate change or the state of the environment. First, the national Finnish emissions were evaluated using the Finnish Regional Emission Scenarios (FRESs) model on a resolution of 250×250 m 2 for the whole of Finland. Second, the atmospheric dispersion was analysed by using the chemical transport model, namely the System for Integrated modeLling of Atmospheric coMposition (SILAM) model, and the source receptor matrices contained in the FRES model. Third, the health impacts were assessed by combining the spatially resolved concentration and population data sets and by analysing the impacts for various health outcomes. Fourth, the economic impacts of the health outcomes were evaluated. The model can be used to evaluate the costs of the health damages for various emission source categories and for a unit of emissions of PM 2.5 . It was found that the economic benefits, in terms of avoided public health costs, were largest for measures that will reduce the emissions of (i) road transport, (ii) non-road vehicles and machinery, and (iii) residential wood combustion. The reduction in the precursor emissions of PM 2.5 resulted in clearly lower benefits when compared with directly reducing the emissions of PM 2.5 . We have also designed a user-friendly, web-based assessment tool that is open access.
A coordinated observational and modelling campaign targeting biogenic aerosols in the air was performed during spring 2021 at two locations in Northern Europe: Helsinki (Finland) and Siauliai (Lithuania), approximately 500 km from each other in north-south direction. The campaign started on March 1, 2021 in Siauliai (12 March in Helsinki) and continued till mid-May in Siauliai (end of May in Helsinki), thus recording the transition of the atmospheric biogenic aerosols profile from winter to summer. The observations included a variety of samplers working on different principles. The core of the program was based on 2- and 2.4--hourly sampling in Helsinki and Siauliai, respectively, with sticky slides (Hirst 24-h trap in Helsinki, Rapid-E slides in Siauliai). The slides were subsequently processed extracting the DNA from the collected aerosols, which was further sequenced using the 3-rd generation sequencing technology. The core sampling was accompanied with daily and daytime sampling using standard filter collectors. The hourly aerosol concentrations at the Helsinki monitoring site were obtained with a Poleno flow cytometer, which could recognize some of the aerosol types. The sampling campaign was supported by numerical modelling. For every sample, SILAM model was applied to calculate its footprint and to predict anthropogenic and natural aerosol concentrations, at both observation sites. The first results confirmed the feasibility of the DNA collection by the applied techniques: all but one delivered sufficient amount of DNA for the following analysis, in over 40% of the cases sufficient for direct DNA sequencing without the PCR step. A substantial variability of the DNA yield has been noticed, generally not following the diurnal variations of the total-aerosol concentrations, which themselves showed variability not related to daytime. An expected upward trend of the biological material amount towards summer was observed but the day-to-day variability was large. The campaign DNA analysis produced the first high-resolution dataset of bioaerosol composition in the North-European spring. It also highlighted the deficiency of generic DNA databases in applications to atmospheric biota: about 40% of samples were not identified with standard bioinformatic methods.
3 September 2024 in Atmospheric Measurement Techniques
The study evaluated a new model of a Plair SA airflow cytometer, Rapid-E+, and assessed its suitability for airborne pollen monitoring within operational networks. Key features of the new model are compared with the previous one, Rapid-E. A machine learning algorithm is constructed and evaluated for (i) classification of reference pollen types in laboratory conditions and (ii) monitoring in real-life field campaigns. The second goal of the study was to evaluate the device usability in forthcoming monitoring networks, which would require similarity and reproducibility of the measurement signal across devices. We employed three devices and analysed (dis-)similarities of their measurements in laboratory conditions. The lab evaluation showed similar recognition performance to that of Rapid-E, but field measurements in conditions when several pollen types were present in the air simultaneously showed notably lower agreement of Rapid-E+ with manual Hirst-type observations than those of the older model. An exception was the total-pollen measurements. Comparison across the Rapid-E+ devices revealed noticeable differences in fluorescence measurements between the three devices tested. As a result, application of the recognition algorithm trained on the data from one device to another led to large errors. The study confirmed the potential of the fluorescence measurements for discrimination between different pollen classes, but each instrument needed to be trained individually to achieve acceptable skills. The large uncertainty of fluorescence measurements and their variability between different devices need to be addressed to improve the device usability.
The study evaluated a new model of a Plair SA air flow cytometer, Rapid-E+, and assessed its suitability for airborne pollen monitoring within operational networks. Key features of the new model are compared with the previous one, Rapid-E. A machine learning algorithm is constructed and evaluated for (i) classification of reference pollen types in laboratory conditions and (ii) monitoring in real-life field campaigns. The second goal of the study was to evaluate the device usability in forthcoming monitoring networks, which would require similarity and reproducibility of the measurement signal across devices. We employed three devices and analysed (dis-)similarities of their measurements in laboratory conditions. The lab evaluation showed similar recognition performance as that of Rapid-E, but field measurements in conditions when several pollen types are present in the air simultaneously, showed a notably lower agreement of Rapid-E+ with manual Hirst-type observations than those of the older model. An exception was the total-pollen measurements. Comparison across the Rapid-E+ devices revealed noticeable differences in fluorescence measurements between the three devices tested. As a result, application of the recognition algorithm trained on the data of one device to another one led to large errors. The study confirmed the potential of the fluorescence measurements for discrimination between different pollen classes, but each monitor needed to be trained individually to achieve acceptable skills. A large uncertainty of fluorescence measurements and their variability between different devices need to be addressed to improve the device usability.