1 May 2023 in Circulation: Cardiovascular Interventions
Background: The potential benefit of transcatheter aortic valve replacement (TAVR) in patients with nonsevere aortic stenosis (AS) and heart failure is controversial. This study aimed to assess outcomes of patients with nonsevere low-gradient AS (LGAS) and reduced left ventricular ejection fraction undergoing TAVR or medical management. Methods: Patients undergoing TAVR for LGAS and reduced left ventricular ejection fraction (<50%) were included in a multinational registry. True-severe low-gradient AS (TS-LGAS) and pseudo-severe low-gradient AS (PS-LGAS) were classified according to computed tomography-derived aortic valve calcification thresholds. A medical control group with reduced left ventricular ejection fraction and moderate AS or PS-LGAS was used (Medical-Mod). Adjusted outcomes between all groups were compared. Among patients with nonsevere AS (moderate or PS-LGAS), outcomes after TAVR and medical therapy were compared using propensity score-matching. Results: A total of 706 LGAS patients undergoing TAVR (TS-LGAS, N=527; PS-LGAS, N=179) and 470 Medical-Mod patients were included. After adjustment, both TAVR groups showed superior survival compared with Medical-Mod patients (all P <0.001), while no difference was found between TS-LGAS and PS-LGAS TAVR patients ( P =0.96). After propensity score-matching among patients with nonsevere AS, PS-LGAS TAVR patients showed superior 2-year overall (65.4%) and cardiovascular survival (80.4%) compared with Medical-Mod patients (48.8% and 58.5%, both P ≤0.004). In a multivariable analysis including all patients with nonsevere AS, TAVR was an independent predictor of survival (hazard ratio, 0.39 [95% CI, 0.27–0.55]; P <0.0001). Conclusions: Among patients with nonsevere AS and reduced left ventricular ejection fraction, TAVR represents a major predictor of superior survival. These results reinforce the need for randomized-controlled trials comparing TAVR versus medical management in heart failure patients with nonsevere AS. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04914481.
4 July 2023 in Journal of the American Heart Association
Background: Little is known about the impact of transcatheter mitral valve edge‐to‐edge repair on changes in left ventricular ejection fraction (LVEF) and the effect of an acute reduction in LVEF on prognosis. We aimed to assess changes in LVEF after transcatheter mitral valve edge‐to‐edge repair for both primary and secondary mitral regurgitation (PMR and SMR, respectively), identify rates and predictors of LVEF reduction, and estimate its impact on prognosis. Methods and Results: In this international multicenter registry, patients with both PMR and SMR undergoing transcatheter mitral valve edge‐to‐edge repair were included. We assessed rates of acute LVEF reduction (LVEFR), defined as an acute relative decrease of >15% in LVEF, its impact on all‐cause mortality, major adverse cardiac event (composite end point of all‐cause death, mitral valve surgery, and residual mitral regurgitation grade ≥2), and LVEF at 12 months, as well as predictors for LVEFR. Of 2534 patients included (727 with PMR, and 1807 with SMR), 469 (18.5%) developed LVEFR. Patients with PMR were older (79.0±9.2 versus 71.8±8.9 years; P <0.001) and had higher mean LVEF (54.8±14.0% versus 32.7±10.4%; P <0.001) at baseline. After 6 to 12 months (median, 9.9 months; interquartile range, 7.8–11.9 months), LVEF was significantly lower in patients with PMR (53.0% versus 56.0%; P <0.001) but not in patients with SMR. The 1‐year mortality was higher in patients with PMR with LVEFR (16.9% versus 9.7%; P <0.001) but not in those with SMR ( P =0.236). LVEF at baseline (odds ratio, 1.03 [95% CI, 1.01–1.05]; P =0.002) was predictive of LVEFR for patients with PMR, but not those with SMR ( P =0.092). Conclusions: Reduction in LVEF is not uncommon after transcatheter mitral valve edge‐to‐edge repair and is correlated with worsened prognosis in patients with PMR but not patients with SMR. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05311163.
18 May 2020 in Age and Ageing
Transcatheter aortic valve implantation (TAVI) brings symptom relief and improvement in health-related quality of life (HRQoL) in the majority of patients treated for symptomatic, severe aortic stenosis. However, there is a substantial group of patients that do not benefit from TAVI. The aim of this study is to investigate the impact of frailty on HRQoL 1 year after TAVI. The TAVI Care & Cure Program is an ongoing, prospective, observational study including patients referred for TAVI to our institution. A comprehensive geriatric assessment was performed to evaluate existence of frailty using the Erasmus Frailty Score (EFS). HRQoL was assessed using the EQ-5D-5 L at baseline and 1 year after TAVI. 239 patients underwent TAVI and completed HRQoL assessment 1 year after TAVI. Seventy (29.3%) patients were classified as frail (EFS ≥ 3). In non-frail patients, the EQ-5D-5 L index did not change (0.71(± 0.22) to 0.68(± 0.33) points, P = 0.22); in frail patients, the EQ-5D-5 L index decreased from 0.55(±0.26) to 0.44 points (±0.33) (P = 0.022). Frailty was an independent predictor of deteriorated HRQoL 1 year after TAVI (OR 2.24, 95% CI 1.07–4.70, P = 0.003). In frail patients, the absence of peripheral artery disease (OR 0.17, 95% 0.05–0.50, P = 0.001) and renal dysfunction (OR 0.13, 95% CI 0.04–0.41, P = <0.001) at baseline was associated with improved HRQoL 1 year after TAVI. Frailty is associated with deterioration of HRQoL 1 year after TAVI. Notably, HRQoL did improve in frail patients with no peripheral arterial disease or renal impairment at baseline.
3 February 2021 in Catheterization and Cardiovascular Interventions
Background: The MANTA vascular closure device (VCD) is dedicated to large bore access closure and associated with favorable results in selected study populations. Anatomical predictors for access site complications are lacking.Aim: To evaluate MANTA in a real‐world population and identify predictors for vascular complications.Methods: All patients undergoing transfemoral transcatheter aortic valve replacement (TAVR) between January 2016 and May 2020 with MANTA closure were included. Baseline characteristics were collected, pre‐procedural computed tomography and post‐deployment femoral angiograms were analyzed for anatomical differences. The primary endpoint was a composite of access site related major and minor vascular complications at 30 days follow‐up according to the VARC‐2 definitions. Secondary endpoints included bleeding, time to hemostasis, procedural length and incomplete arteriotomy closure or arterial occlusion by angiography. A Cox proportional hazards model was used to compare all‐cause mortality for patients with and without an access site complication.Results: The 512 patients underwent TAVR with MANTA access closure. Median age was 80 (IQR 75–85), 53% was male, median BMI was 26.4 kg/m2 (IQR 23.4–29.7). Access site related major‐ or minor vascular complication occurred in 20 (4%) and 23 (4%) of patients respectively. Median time to hemostasis was 42 s (IQR 28–98). Post deployment angiogram showed an occlusion in 24 patients (5%), incomplete closure in 60 patients (12%) or both in three patients (1%). Of these 87 patients, 36 (41%) had a vascular complication. Femoral artery diameter (OR 0.70 [0.53–0.93]), low‐ (OR 3.47 [1.21–10.00]) and high (OR 2.43 [1.16–5.10]) arteriotomies were independent predictors for vascular complications.Conclusion: In this contemporary TAVR population, access‐site related complications occurred in 8% of patients and were mainly due to percutaneous closure device failure. Small artery diameter and off‐target punctures were independent predictors.
15 April 2024 in Clinical Research in Cardiology
HWHarindra C. Wijeysundera
+10
Background: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. Aims: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. Methods: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. Results: A total of 252 patients were included. The median age was 82 [25th–75th percentile, 78–85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th–75th percentile, 1.6–3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th–75th percentile, 0.31–2.26], p = 0.73, and OR 0.97 [25th–75th percentile, 0.46–2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. Conclusion: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay. Graphical Safety and feasibility of early discharge after transcatheter aortic valve implantation with ACURATE Neo, an international multi-center, prospective observational single-arm study. OR, odds ratio (95% confidence interval); VARC, Valve Academic Research Consortium