The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
JT-60SA is one of the largest superconducting tokamaks in the world, and its commissioning is ongoing to achieve the first plasma. The power supply (PS) for superconducting coils consists of ac/dc converter, switching network unit, and quench protection circuit. These subcomponents are required for each coil, and therefore, multiple subcomponents are used in JT-60SA. For plasma discharge, these many subcomponents need to be operated simultaneously, and this commissioning for system integration is an important issue. In the commissioning so far, the toroidal field (TF) coils were energized up to the rated current of 25.7 kA, and plasma was generated by the electron cyclotron range of frequency (ECRF) injection. In TF coils, fast discharge for quench protection was successfully achieved at a high current of 18 kA, which is 70% of the rated current. PF coils have been energized one by one up to $\pm$ 5 kA, which is 25% of the rated current, and a high voltage of $\pm$ 5 kV required for inductive plasma initiation was applied to the coils. The commissioning strategy for system integration of the coil PSs and these initial results are described in this article.
Recently, in especially private college in Japan, dispersion of students' educational achievement is distinguished, and fundamental educations for freshmen become more important. The education materials, which raise the level of low-achievement students and interest other students simultaneously, are required. Then we present a teaching material system and project-style education of fundamental mathematics for freshmen, which was demonstrated in our department. It is highlighted that using this system we assign each student each data composing a project, so that we succeed in not only improving education effect but also constructing the decentralized data-making/acquisition system with students
28 February 2023 in IEEE Transactions on Applied Superconductivity
For the large research Tokamak JT-60SA, evaluating the withstand voltage between conductors is one of the most critical factors for the coil design. The power supply feeding the coil injects a wide spectrum of frequency components. The transient response and resonance phenomena induce a non-uniform voltage distribution in the coil. The transiently concentrated voltage can cause the insulation breakdown between conductors, and JT-60SA may not be able to operate safely. This study conducted an impulse test to evaluate the withstand voltage between adjacent conductors for an equilibrium field (EF) coil. The actual power supply voltage for the EF coil was measured to investigate the ramp rate (dv/dt) and frequency spectrum. In addition, based on the results of a resonance test of the EF dummy coil, a circuit simulation model for the EF coil was developed to evaluate the effect of the transient response and resonance phenomenon on the voltage in the coil. The results of this study provide fundamental data that can be used to ensure that the EF coil does not cause insulation breakdown.
24 January 2024 in IEEE Transactions on Applied Superconductivity
The JT-60SA Poloidal Field (PF) coils system comprises four Central Solenoid (CS) modules and six Equilibrium Field (EF) coils, and the cryostat, vacuum vessel (VV), and stabilizing plate (SP) are installed around the PF coil. Evaluating the voltage between conductors in the PF coils is one of the most critical factors in the energized coil operation and the insulation design. The power supply voltage of the PF coils has some frequency components caused by the voltage control system. The resonance phenomena caused by the voltage fluctuations of the power supply induce a non-uniform voltage distribution in the coil. The locally concentrated voltage may exceed the withstand voltage of the insulation, affecting the operation of the JT-60SA. In this study, a circuital model was assembled including four CS modules and six EF coils, to estimate the resonance frequency effect into the coil voltage distribution. In addition, the effects of the cryostat, VV, and SP on the voltage between conductors in the PF coils were evaluated.