Mathias Nittka

Mathias Nittka

Auto-generated profile, based on publicly available information

Mathias Nittka

MRI-sequence developer, Magnetic Resonance, Siemens Healthcare GmbH, Erlangen, Enkestraße 127, Erlangen 91052, Germany

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Radiology
Verified
Journal Article
Closed access
GKGregor Koerzdoerfer
Gregor Koerzdoerfer
RKRainer Kirsch
Rainer Kirsch
KLKecheng Liu
Kecheng Liu
JPJosef Pfeuffer
Josef Pfeuffer
BHBernhard Hensel
Bernhard Hensel
MNMathias Nittka
Mathias Nittka
Relaxation times in solid compartments of the human brain measured with fast imaging with steady-state free precession MR fingerprinting varied less than 8.0% (95% confidence intervals: −8.0%, 8.0%... Background Only sparse literature investigates the reproducibility and repeatability of relaxometry methods in MRI. However, statistical data on reproducibility and repeatability of any quantitativ...

1 June 2018 in European Journal of Radiology
Verified
Journal Article
Closed access
AGAlexandra Grimm
Alexandra Grimm
HMHeiko Meyer
Heiko Meyer
MNMarcel Dominik Nickel
Marcel Dominik Nickel
MNMathias Nittka
Mathias Nittka
EREsther Raithel
Esther Raithel
KEKlaus Engelke
Klaus Engelke

1 September 2021 in Magnetic Resonance Imaging
Verified
Journal Article
Closed access
ACAdrienne E. Campbell-Washburn
Adrienne E. Campbell-Washburn
YJYun Jiang
Yun Jiang
GKGregor Koerzdoerfer
Gregor Koerzdoerfer
MNMathias Nittka
Mathias Nittka
MGMark A. Griswold
Mark A. Griswold

30 January 2022 in Cancers
Verified
Journal Article
Open access
PDF file
ESElisabeth Springer
Elisabeth Springer
PCPedro De Lima Cardoso
Pedro De Lima Cardoso
BSBernhard Strasser
Bernhard Strasser
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
MPMatthias Preusser
Matthias Preusser
Siegfried TrattnigSiegfried Trattnig
Siegfried Trattnig
(1) Background: Advanced MR imaging (MRI) of brain tumors is mainly based on qualitative contrast images. MR Fingerprinting (MRF) offers a novel approach. The purpose of this study was to use MRF-derived T1 and T2 relaxation maps to differentiate diffuse gliomas according to isocitrate dehydrogenase (IDH) mutation. (2) Methods: Twenty-four patients with histologically verified diffuse gliomas (14 IDH-mutant, four 1p/19q-codeleted, 10 IDH-wildtype) were enrolled. MRF T1 and T2 relaxation times were compared to apparent diffusion coefficient (ADC), relative cerebral blood volume (rCBV) within solid tumor, peritumoral edema, and normal-appearing white matter (NAWM), using contrast-enhanced MRI, diffusion-, perfusion-, and susceptibility-weighted imaging. For perfusion imaging, a T2* weighted perfusion sequence with leakage correction was used. Correlations of MRF T1 and T2 times with two established conventional sequences for T1 and T2 mapping were assessed (a fast double inversion recovery-based MR sequence (‘MP2RAGE’) for T1 quantification and a multi-contrast spin echo-based sequence for T2 quantification). (3) Results: MRF T1 and T2 relaxation times were significantly higher in the IDH-mutant than in IDH-wildtype gliomas within the solid part of the tumor (p = 0.024 for MRF T1, p = 0.041 for MRF T2). MRF T1 and T2 relaxation times were significantly higher in the IDH-wildtype than in IDH-mutant gliomas within peritumoral edema less than or equal to 1cm adjacent to the tumor (p = 0.038 for MRF T1 mean, p = 0.010 for MRF T2 mean). In the solid part of the tumor, there was a high correlation between MRF and conventionally measured T1 and T2 values (r = 0.913, p < 0.001 for T1, r = 0.775, p < 0.001 for T2), as well as between MRF and ADC values (r = 0.813, p < 0.001 for T2, r = 0.697, p < 0.001 for T1). The correlation was weak between the MRF and rCBV values (r = −0.374, p = 0.005 for T2, r = −0.181, p = 0.181 for T1). (4) Conclusions: MRF enables fast, single-sequence based, multi-parametric, quantitative tissue characterization of diffuse gliomas and may have the potential to differentiate IDH-mutant from IDH-wildtype gliomas.


24 May 2018 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
THTim Hilgenfeld
Tim Hilgenfeld
MPM. Prager
M. Prager
FSFranz Sebastian Schwindling
Franz Sebastian Schwindling
MNM. Nittka
M. Nittka
PRPeter Rammelsberg
Peter Rammelsberg
AJA. Juerchott
A. Juerchott
BACKGROUND AND PURPOSE: The incidence of metallic dental restorations and implants is increasing, and head and neck MR imaging is becoming challenging regarding artifacts. Our aim was to evaluate whether multiple-slab acquisition with view angle tilting gradient based on a sampling perfection with application-optimized contrasts by using different flip angle evolution (MSVAT-SPACE)-STIR and slice-encoding for metal artifact correction (SEMAC)-STIR are beneficial regarding artifact suppression compared with the SPACE-STIR and TSE-STIR in vitro and in vivo. MATERIALS AND METHODS: At 3T, 3D artifacts of 2 dental implants, supporting different single crowns, were evaluated. Image quality was evaluated quantitatively (normalized signal-to-noise ratio) and qualitatively (2 reads by 2 blinded radiologists). Feasibility was tested in vivo in 5 volunteers and 5 patients, respectively. RESULTS: Maximum achievable resolution and the normalized signal-to-noise ratio of MSVAT-SPACE-STIR were higher compared with SEMAC-STIR. Performance in terms of artifact correction was dependent on the material composition. For highly paramagnetic materials, SEMAC-STIR was superior to MSVAT-SPACE-STIR (27.8% smaller artifact volume) and TSE-STIR (93.2% less slice distortion). However, MSVAT-SPACE-STIR reduced the artifact size compared with SPACE-STIR by 71.5%. For low-paramagnetic materials, MSVAT-SPACE-STIR performed as well as SEMAC-STIR. Furthermore, MSVAT-SPACE-STIR decreased artifact volume by 69.5% compared with SPACE-STIR. The image quality of all sequences did not differ systematically. In vivo results were comparable with in vitro results. CONCLUSIONS: Regarding susceptibility artifacts and acquisition time, MSVAT-SPACE-STIR might be advantageous over SPACE-STIR for high-resolution and isotropic head and neck imaging. Only for materials with high-susceptibility differences to soft tissue, the use of SEMAC-STIR might be beneficial. Within limited acquisition times, SEMAC-STIR cannot exploit its full advantage over TSE-STIR regarding artifact suppression.