Geraint Chaffey

Geraint Chaffey

Auto-generated profile, based on publicly available information

Geraint Chaffey

Research Group ELECTA, Department of Electrical Engineering, KU Leuven, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
MWMian Wang
Mian Wang
WLWillem Leterme
Willem Leterme
GCGeraint Chaffey
Geraint Chaffey
JBJef Beerten
Jef Beerten
DHDirk Van Hertem
Dirk Van Hertem
Pole rebalancing in symmetrical monopolar HVDC grids is necessary to remove pole imbalances resulting from pole-to-ground faults. For selective protection employing DC breakers, the interaction between DC breakers and pole rebalancing methods have not been studied. This paper proposes new strategies for pole rebalancing methods to deal with DC breaker operation in HVDC grids. A complete analysis of pole rebalancing using equipment at DC or AC side is performed for all stages of the fault clearing process. Based on the analysis, new control strategies are proposed to optimize the use of the pole rebalancing equipment. The proposed control methods are shown to enable the pole rebalancing equipment to meet the required high protection speed and low losses. Both DC and AC side equipment such as dynamic braking systems and AC groundings are investigated and proven to be applicable for pole rebalancing in selective protection strategies. The impact of the breaker technology on the interaction between DC breaker requirements and pole rebalancing needs is investigated in detail. The conclusions are validated using EMTP simulation on a four terminal test grid.

17 March 2021 in IEEE Access
Verified
Journal Article
Open access
THTheodor Heath
Theodor Heath
MBMike Barnes
Mike Barnes
PJPaul D. Judge
Paul D. Judge
GCGeraint Chaffey
Geraint Chaffey
PCPhil Clemow
Phil Clemow
JAJack Andrews
Jack Andrews
The increasing importance of cascaded multilevel converters (CMCs), and the sub-category of modular multilevel converters (MMCs), is illustrated by their wide use in high voltage DC connections and in static compensators. Research is being undertaken into the use of these complex pieces of hardware and software for a variety of grid support services, on top of fundamental frequency power injection, requiring improved control for non-traditional duties. To validate these results, small-scale laboratory hardware prototypes are often required. Such systems have been built by many research teams around the globe and are also increasingly commercially available. Few publications go into detail on the construction options for prototype CMCs, and there is a lack of information on both design considerations and lessons learned from the build process, which will hinder research and the best application of these important units. This paper reviews options, gives key examples from leading research teams, and summarizes knowledge gained in the development of test rigs to clarify design considerations when constructing laboratory-scale CMCs.

12 March 2021 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
MWMian Wang
Mian Wang
WLWillem Leterme
Willem Leterme
GCGeraint Chaffey
Geraint Chaffey
JBJef Beerten
Jef Beerten
DHDirk Van Hertem
Dirk Van Hertem
Multi‐vendor interoperable HVDC grid protection is key to build large‐scale HVDC grids in a step‐by‐step manner. On the one hand, various protection strategies and technologies have been developed in the past decade to address the challenges associated with HVDC grid protection. On the other hand, state‐of‐the‐art HVDC technologies are often vendor‐specific and there is a general lack of standardisation on HVDC systems as the majority of existing HVDC systems have been built by single vendors as turn‐key projects. In recent years, driven by the need to develop multi‐vendor HVDC grids, both national and international standardisation bodies have been working on guidelines and pre‐standardisation for HVDC systems. This paper provides a comprehensive review of the recent progress on HVDC grid protection focusing on multi‐vendor interoperability and identifies the main challenges to achieve interoperable HVDC grid protection. Compared to AC system protection, the fundamental differences of multi‐vendor interoperability in HVDC grid protection are the possible co‐existence of multiple protection philosophies and the extended scope of the fault clearing process in terms of protection and control. The challenges and research needs related to multi‐vendor HVDC grid protection due to these fundamental differences are identified.

30 January 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
IJIlka Jahn
Ilka Jahn
FHFabian Hohn
Fabian Hohn
GCGeraint Chaffey
Geraint Chaffey
SNStaffan Norrga
Staffan Norrga
The integration of large amounts of renewable energy will require multiterminal high-voltage direct-current (MTDC) grids to reliably transport the energy over long distances. However, before building an MTDC grid, a functional protection system design is needed. Realistic and industrial studies are required to validate the functionality of such a system. In addition, further academic research as well as education in the field are needed. This paper presents an open-source, low-cost protection intelligent electronic device (IED) prototype for use in a laboratory environment. In particular, the IED design, its fastest measured performance, example results for different fault scenarios, and an assessment of its use in education are shown. The open-source IED is useful to accelerate industrial and academic research, as well as to enable education in protection for MTDC grids.

21 July 2020 in IEEE Transactions on Circuits and Systems I: Regular Papers
Verified
Journal Article
Closed access
XXXin Xiang
Xin Xiang
XZXiaotian Zhang
Xiaotian Zhang
YGYunjie Gu
Yunjie Gu
GCGeraint P. Chaffey
Geraint P. Chaffey
TGTimothy C. Green
Timothy C. Green
Chain-link modular multilevel direct dc-dc converters (CLMMCs) have attracted much interest recently in for dc power systems because they achieve higher device utilization, lower power losses and they are physically more compact than the alternative front-to-front modular multilevel dc-ac-dc converters (FFMMCs). The CLMMCs rely on circulating an internal ac current to manage energy balance of the sub-module (SM) stacks but this current inevitably contributes to extra current stresses for circuit components and can also lead to excess reactive power circulation within the converter. This paper presents a circuit analysis that there exists a frequency value for the internal ac components that may minimize the current stresses and avoid excessive reactive power circulation. For illustration, the circuit analysis is applied to one of the base formats, the buck-boost CLMMC as an example. The key relationship between the CLMMC and the standard dc-ac modular multilevel converter is explored and established. The equivalent circuits for their dc and ac components with consideration of SM capacitance and SM voltage ripples are created and analyzed in detail, and a full derivation is provided for the specific ac frequency. From this example, this analytical method is extended and applied to other base formats of CLMMCs. The theoretical analysis and results are verified by a set of full-scale simulation examples and down-scaled experiments on a laboratory prototype.

10 May 2017 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Verified
Journal Article
Closed access
JTJulien Thomas
Julien Thomas
GCGeraint P. Chaffey
Geraint P. Chaffey
CFChristian M. Franck
Christian M. Franck
Circuit breakers are anticipated for fault isolation in multiterminal HVdc networks. However, there are remaining challenges concerning the circuit breaker topology and operation. The passive oscillation principle circuit breaker is one of the topologies under consideration, the design of which requires examination of the arc characteristics. The design process is therefore presented, with the aim of constructing a small-scale prototype. First, a horizontal nozzle constricted arc setup with a blowing capability is built in order to study the stationary and transient arc characteristics P(g) and τ(g), which are essential for the design of this type of breaker. Second, after their extraction from measurements, these two arc parameters are inserted into a simulation model based on the Mayr-Schwarz arc equation, which predicts an effective breaker operation. Finally, a passive oscillation principle breaker is constructed and successfully tested with both an arbitrary current source and on a scaled voltage source converter network.