Mathias Langer

Mathias Langer

Auto-generated profile, based on publicly available information

Mathias Langer

Department of Radiology, University Hospital of Freiburg, Freiburg, Germany

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2007 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
MMMichael Markl
Michael Markl
AHAndreas Harloff
Andreas Harloff
TBThorsten A. Bley
Thorsten A. Bley
MZMaxim Zaitsev
Maxim Zaitsev
BJBernd Jung
Bernd Jung
AFAlex Frydrychowicz
Alex Frydrychowicz
Purpose: To evaluate an improved image acquisition and data‐processing strategy for assessing aortic vascular geometry and 3D blood flow at 3T.Materials and Methods: In a study with five normal volunteers and seven patients with known aortic pathology, prospectively ECG‐gated cine three‐dimensional (3D) MR velocity mapping with improved navigator gating, real‐time adaptive k‐space ordering and dynamic adjustment of the navigator acceptance criteria was performed. In addition to morphological information and three‐directional blood flow velocities, phase‐contrast (PC)‐MRA images were derived from the same data set, which permitted 3D isosurface rendering of vascular boundaries in combination with visualization of blood‐flow patterns.Results: Analysis of navigator performance and image quality revealed improved scan efficiencies of 63.6% ± 10.5% and temporal resolution (<50 msec) compared to previous implementations. Semiquantitative evaluation of image quality by three independent observers demonstrated excellent general image appearance with moderate blurring and minor ghosting artifacts. Results from volunteer and patient examinations illustrate the potential of the improved image acquisition and data‐processing strategy for identifying normal and pathological blood‐flow characteristics.Conclusion: Navigator‐gated time‐resolved 3D MR velocity mapping at 3T in combination with advanced data processing is a powerful tool for performing detailed assessments of global and local blood‐flow characteristics in the aorta to describe or exclude vascular alterations. J. Magn. Reson. Imaging 2007.

1 August 2010 in Radiology
Verified
Journal Article
Closed access
GPGregor Pache
Gregor Pache
BKBernhard Krauss
Bernhard Krauss
PSPeter Strohm
Peter Strohm
USUlrich Saueressig
Ulrich Saueressig
PBPhilipp Blanke
Philipp Blanke
TBTobias Baumann
Tobias Baumann
To evaluate traumatized bone marrow with a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique. In this prospective institutional review board-approved study, 21 patients with an acute knee trauma underwent DE CT and magnetic resonance (MR) imaging. A software application was used to virtually subtract calcium from the images. Presence of fractures was noted, and presence of bone bruise was rated on a four-point scale for six femoral and tibial regions by two radiologists. CT numbers were obtained in the same regions. Consensus reading of independently read MR images served as the reference standard. Image ratings and CT numbers were subjected to receiver operating characteristic curve analysis. After exclusion of 16 regions owing to artifacts, MR imaging revealed 59 bone bruises in the remaining 236 regions (19 of 114 femoral, 40 of 122 tibial). Fractures were present in eight patients. Visual rating revealed areas under the curve of 0.886 and 0.897 in the femur and 0.974 and 0.953 in the tibia for observers 1 and 2, respectively. For CT numbers, the respective areas under the curve were 0.922 and 0.974. If scores of 1 and 2 (strong or mild bone bruise) were counted as positive, sensitivities were 86.4% and 86.4% and specificities were 94.4% and 95.5% for observers 1 and 2, respectively. The kappa statistic demonstrated good to excellent agreement (femur, kappa = 0.78; tibia, kappa = 0.87). This DE CT virtual noncalcium technique can subtract calcium from cancellous bone, allowing bone marrow assessment and potentially making posttraumatic bone bruises of the knee detectable with CT.

1 January 2012 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
JBJonas Bürk
Jonas Bürk
PBPhilipp Blanke
Philipp Blanke
ZSZoran Stankovic
Zoran Stankovic
ABAlex Barker
Alex Barker
MRMaximilian Russe
Maximilian Russe
MMMichael Markl
Michael Markl
The purpose of this study was to investigate 3D flow patterns and vessel wall parameters in patients with dilated ascending aorta, age-matched subjects, and healthy volunteers. Thoracic time-resolved 3D phase contrast CMR with 3-directional velocity encoding was applied to 33 patients with dilated ascending aorta (diameter ≥40 mm, age=60±16 years), 15 age-matched normal controls (diameter ≤37 mm, age=68±7.5 years) and 15 young healthy volunteers (diameter ≤30 mm, age=23±2 years). 3D blood flow was visualized and flow patterns were graded regarding presence of supra-physiologic-helix and vortex flow using a semi-quantitative 3-point grading scale. Blood flow velocities, regional wall shear stress (WSS), and oscillatory shear index (OSI) were quantified. Incidence and strength of supra-physiologic-helix and vortex flow in the ascending aorta (AAo) was significantly higher in patients with dilated AAo (16/33 and 31/33, grade 0.9±1.0 and 1.5±0.6) than in controls (2/15 and 7/15, grade 0.2 ± 0.6 and 0.6 ± 0.7, P<.05) or healthy volunteers (1/15 and 0/15, grade 0.1 ± 0.3 P<.05). Greater strength of the ascending aortic helix and vortex flow were associated with significant differences in AAo diameters (P<.05). Peak systolic WSS in the ascending aorta and aortic arch was significantly lower in patients with dilated AAo (P<.0157-.0488). AAo diameter positively correlated to time to peak systolic velocities (r=0.30-0.53, P<.04), OSI (r=0.33-0.49, P<0.02) and inversely correlated to peak systolic WSS (r=0.32-0.40, P<.03). Peak systolic WSS was significantly lower in AAo aneurysms at the right and outer curvature within the AAo and proximal arch (P<.01-.05). Increase in AAo diameter is significantly correlated with the presence and strength of supra-physiologic-helix and vortex formation in the AAo, as well with decrease in systolic WSS and increase in OSI.

1 January 2005 in American Journal of Roentgenology
Verified
Journal Article
Closed access
TBThorsten A. Bley
Thorsten A. Bley
OWOliver Wieben
Oliver Wieben
MUMarkus Uhl
Markus Uhl
JTJens Thiel
Jens Thiel
DSDieter Schmidt
Dieter Schmidt
MLMathias Langer
Mathias Langer
OBJECTIVE. This study investigated the hypothesis that high-resolution MRI can reveal mural inflammatory changes of the superficial temporal artery in giant cell arteritis (GCA).SUBJECTS AND METHODS. MRI of the temporal artery of 20 patients with suspected GCA was performed on a 1.5-T scanner using a dedicated eight-element phased-array head coil. Contrast-enhanced multislice T1-weighted spin-echo sequences were acquired perpendicular to the orientation of the vessel, with a submillimeter spatial resolution of 0.2 × 0.3 mm and a slice thickness of 3 mm. Mural thickness and lumen diameter of the temporal artery were measured, and mural contrast enhancement was graded on a four-point scale by two radiologists. For all patients, the MRI results were compared with the findings of clinical examination and laboratory tests. In addition, biopsy samples of the temporal artery were taken from 16 of these patients.RESULTS. MRI sharply demonstrated the superficial temporal artery, allowing an evaluation of its lumen...

25 June 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
AFAlex Frydrychowicz
Alex Frydrychowicz
ASAurélien F. Stalder
Aurélien F. Stalder
MRMaximilian F. Russe
Maximilian F. Russe
JBJelena Bock
Jelena Bock
SBSimon Bauer
Simon Bauer
MMMichael Markl
Michael Markl
Purpose: To assess the distribution and regional differences of flow and vessel wall parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) in the entire thoracic aorta.Materials and Methods: Thirty‐one healthy volunteers (mean age = 23.7 ± 3.3 years) were examined by flow‐sensitive four‐dimensional (4D)‐MRI at 3T. For eight retrospectively positioned 2D analysis planes distributed along the thoracic aorta, flow parameters and vectorial WSS and OSI were assessed in 12 segments along the vascular circumference.Results: Mean absolute time‐averaged WSS ranged between 0.25 ± 0.04 N/m2 and 0.33 ± 0.07 N/m2 and incorporated a substantial circumferential component (–0.05 ± 0.04 to 0.07 ± 0.02 N/m2). For each analysis plane, a segment with lowest absolute WSS and highest OSI was identified which differed significantly from mean values within the plane (P < 0.05). The distribution of atherogenic low WSS and high OSI closely resembled typical locations of atherosclerotic lesions at the inner aortic curvature and supraaortic branches.Conclusion: The normal distribution of vectorial WSS and OSI in the entire thoracic aorta derived from flow‐sensitive 4D‐MRI data provides a reference constituting an important perquisite for the examination of patients with aortic disease. Marked regional differences in absolute WSS and OSI may help explaining why atherosclerotic lesions predominantly develop and progress at specific locations in the aorta. J. Magn. Reson. Imaging 2009;30:77–84.

1 August 2012 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
PBPhilipp Blanke
Philipp Blanke
JRJochen Reinöhl
Jochen Reinöhl
CSChristian Schlensak
Christian Schlensak
MSMatthias Siepe
Matthias Siepe
GPGregor Pache
Gregor Pache
MZManfred Zehender
Manfred Zehender
Background—: To retrospectively investigate the potential cause of contained rupture of the aortic root in balloon-expandable transcatheter aortic valve implantation (TAVI) by means of pre- and postinterventional multislice computed tomography. Methods and Results—: Seventy-two patients (mean age 82±7 years, mean aortic valve area 0.69±0.19 cm 2 ) underwent balloon-expandable TAVI using the EdwardsSAPIEN Transcatheter Heart Valve (23 mm, n=19; 26 mm, n=50; 29 mm, n=3). Aortic annulus dimensions were quantified by multislice computed tomography–based cross-sectional area assessment and average diameter calculation (CAAD) before and after TAVI. Post-TAVI multislice computed tomography data sets were available in 65 patients; contained aortic root rupture was diagnosed in 3 patients. Pre-TAVI CAAD was 23.1±1.8 mm; post-TAVI CAAD was 22.9±1.3 mm. Median relative change in CAAD pre- and post-TAVI was −0.5% (interquartile range, 3.6%). Relative increase of 5% to 10% was observed in 4 patients (1 with contained rupture), relative increase >10% in 2 patients, both with contained rupture. Mean relative oversizing, calculated as the relative difference in diameter between pre-TAVI CAAD and nominal diameter of the selected prosthesis, was 9.8%±7.8%. Relative oversizing was significantly higher in patients with contained rupture compared with patients without contained rupture (24.6%±5.4% versus 9.1%±6.6%; P <0.001). Relative oversizing ≥20% occurred in 6 patients (3 with contained rupture). Conclusions—: Contained rupture of the aortic root in balloon-expandable TAVI is associated with severe prosthesis oversizing. Multislice computed tomography–based assessment of aortic annulus dimension in conjunction with adapted sizing guidelines may reduce the incidence of severe oversizing.