Lucas Lampier

Lucas Lampier

Auto-generated profile, based on publicly available information

Lucas Lampier

Federal University of Espírito Santo, Vitória, Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2022 in Physiological Measurement
Verified
Journal Article
Closed access
LLLucas Côgo Lampier
Lucas Côgo Lampier
CVCarlos Torturella Valadão
Carlos Torturella Valadão
LSLeticia Araújo Silva
Leticia Araújo Silva
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
ECEliete Maria de Oliveira Caldeira
Eliete Maria de Oliveira Caldeira
TBTeodiano Freire Bastos-Filho
Teodiano Freire Bastos-Filho
Objective. This study proposes a U-net shaped Deep Neural Network (DNN) model to extract remote photoplethysmography (rPPG) signals from skin color signals to estimate Pulse Rate (PR). Approach. Three input window sizes are used in the DNN: 256 samples (5.12 s), 512 samples (10.24 s), and 1024 (20.48 s). A data augmentation algorithm based on interpolation is also used here to artificially increase the number of training samples. Main results. The proposed model outperformed a prior-knowledge rPPG method by using input signals with window of 256 and 512 samples. Also, it was found that the data augmentation procedure only increased the performance for the window of 1024 samples. The trained model achieved a Mean Absolute Error (MAE) of 3.97 Beats per Minute (BPM) and Root Mean Squared Error (RMSE) of 6.47 BPM, for the 256 samples window, and MAE of 3.00 BPM and RMSE of 5.45 BPM for the window of 512 samples. On the other hand, the prior-knowledge rPPG method got a MAE of 8.04 BPM and RMSE of 16.63 BPM for the window of 256 samples, and MAE of 3.49 BPM and RMSE of 7.92 BPM for the window of 512 samples. For the longest window (1024 samples), the concordance of the predicted PRs from the DNNs and the true PRs was higher when applying the data augmentation procedure. Significance. These results demonstrate a big potential of this technique for PR estimation, showing that the DNN proposed here may generate reliable rPPG signals even with short window lengths (5.12 s and 10.24 s), suggesting that it needs less data for a faster rPPG measurement and PR estimation.

8 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
ICIsmael Criollo
Ismael Criollo
CVCarlos Valadão
Carlos Valadão
Leticia SilvaLeticia Silva
Leticia Silva
YCYves Coelho
Yves Coelho
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
COVID-19 occurs due to infection through respiratory droplets containing the SARS-CoV-2 virus, which are released when someone sneezes, coughs, or talks. The gold-standard exam to detect the virus is Real-Time Polymerase Chain Reaction (RT-PCR); however, this is an expensive test and may require up to 3 days after infection for a reliable result, and if there is high demand, the labs could be overwhelmed, which can cause significant delays in providing results. Biomedical data (oxygen saturation level—SpO2, body temperature, heart rate, and cough) are acquired from individuals and are used to help infer infection by COVID-19, using machine learning algorithms. The goal of this study is to introduce the Integrated Portable Medical Assistant (IPMA), which is a multimodal piece of equipment that can collect biomedical data, such as oxygen saturation level, body temperature, heart rate, and cough sound, and helps infer the diagnosis of COVID-19 through machine learning algorithms. The IPMA has the capacity to store the biomedical data for continuous studies and can be used to infer other respiratory diseases. Quadratic kernel-free non-linear Support Vector Machine (QSVM) and Decision Tree (DT) were applied on three datasets with data of cough, speech, body temperature, heart rate, and SpO2, obtaining an Accuracy rate (ACC) and Area Under the Curve (AUC) of approximately up to 88.0% and 0.85, respectively, as well as an ACC up to 99% and AUC = 0.94, respectively, for COVID-19 infection inference. When applied to the data acquired with the IMPA, these algorithms achieved 100% accuracy. Regarding the easiness of using the equipment, 36 volunteers reported that the IPMA has a high usability, according to results from two metrics used for evaluation: System Usability Scale (SUS) and Post Study System Usability Questionnaire (PSSUQ), with scores of 85.5 and 1.41, respectively. In light of the worldwide needs for smart equipment to help fight the COVID-19 pandemic, this new equipment may help with the screening of COVID-19 through data collected from biomedical signals and cough sounds, as well as the use of machine learning algorithms.

8 December 2021 in INGENIUS
Verified
Journal Article
Open access
PDF file
LLLucas C. Lampier
Lucas C. Lampier
YCYves Coelho
Yves Coelho
ECEliete Caldeira
Eliete Caldeira
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
This article describes the methodology used to train and test a Deep Neural Network (DNN) with Photoplethysmography (PPG) data performing a regression task to estimate the Respiratory Rate (RR). The DNN architecture is based on a model used to infer the heart rate (HR) from noisy PPG signals, which is optimized to the RR problem using genetic optimization. Two open-access datasets were used in the tests, the BIDMC and the CapnoBase. With the CapnoBase dataset, the DNN achieved a median error of 1.16 breaths/min, which is comparable with analytical methods in the literature, in which the best error found is 1.1 breaths/min (excluding the 8 % noisiest data). The BIDMC dataset seems to be more challenging, as the minimum median error of the literature’s methods is 2.3 breaths/min (excluding 6 % of the noisiest data), and the DNN based approach achieved a median error of 1.52 breaths/min with the whole dataset.

1 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LLLucas C. Lampier
Lucas C. Lampier
AFAlan Floriano
Alan Floriano
CVCarlos Valadão
Carlos Valadão
Leticia SilvaLeticia Silva
Leticia Silva
ECEliete Caldeira
Eliete Caldeira
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
The COVID-19 pandemic has highlighted the significance of both telemedicine and measuring physiological signals as peripheral Oxygen Saturation (SpO 2 ) at home. Aiming to increase the confiability of SpO 2 readings performed by smartphones, this study presents a novel Deep Neural Network (DNN) model that predicts SpO 2 levels using fingertip videos captured by smartphones. The model was trained and evaluated using the leave-one-out method, and compared against the SpO 2 values measured by a set of oximeters. The dataset used in this work is a differential of the study, unlike most of similar studies which use a breath-holding protocol that presents only a few samples of low SpO 2 values, our tests were evaluated using a publicly available dataset in which volunteers’ SpO 2 levels were measured in a range from almost 100% to approximately 70% by manipulating the percentage of oxygen inhaled by the volunteers, and the SpO 2 levels were kept on lower values for a considerable period of time. The proposed DNN model was compared against multiple variations of the Ratio-of-Rations (RoR) method and the model proposed by the dataset creators. The results show that the DNN outputs have a strong relationship with the true SpO 2 measurements, as indicated by a Pearson coefficient (PC) of 0.95 and a Concordance Correlation Coefficient (CCC) of 0.95, and also a small error, measured by a Root Mean Squared Error (RMSE) of 2.92% and a Mean Absolute Error (MAE) of 1.97%. Compared to the RoR method, which achieved a PC of 0.29, CCC of 0.21, RMSE of 8.83% and MAE of 7.03%, the proposed DNN model exhibits superior performance. Moreover, the proposed DNN model outperforms the model proposed by the dataset authors, which achieved a MAE of 5.00%. These findings demonstrate that the proposed DNN model can accurately predict SpO 2 levels using smartphone-recorded fingertip videos with lower error and higher precision than a widely used classical method.

15 April 2022
Verified
Book Chapter
Closed access
PDF file
LLL. C. Lampier
L. C. Lampier
ECE. Caldeira
E. Caldeira
DDD. Delisle-Rodriguez
D. Delisle-Rodriguez
AFA. Floriano
A. Floriano
TBT. F. Bastos-Filho
T. F. Bastos-Filho

2 March 2021 in Polytechnica
Verified
Journal Article
Closed access
PDF file
AFAlan Floriano
Alan Floriano
LLLucas Lampier
Lucas Lampier
RRRoger S. Rosa
Roger S. Rosa
ECEliete Caldeira
Eliete Caldeira
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho