Teodiano Bastos-Filho

Dr. Teodiano Bastos-Filho

Universidade Federal do Espírito Santo, Vitória, Espírito Santo, Brazil
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2008 in Control Engineering Practice
Verified
Journal Article
Closed access
Felipe Nascimento MartinsFelipe Nascimento Martins
Felipe Nascimento Martins
WCWanderley C. Celeste
Wanderley C. Celeste
RCRicardo Carelli
Ricardo Carelli
MSMário Sarcinelli-Filho
Mário Sarcinelli-Filho
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho

1 August 2013 in Medical Engineering & Physics
Verified
Journal Article
Closed access
PDPablo Diez
Pablo Diez
SMSandra M. Torres Müller
Sandra M. Torres Müller
VMVicente A. Mut
Vicente A. Mut
ELEric Laciar
Eric Laciar
EAEnrique Avila
Enrique Avila
MSMário Sarcinelli-Filho
Mário Sarcinelli-Filho
This work presents a brain-computer interface (BCI) used to operate a robotic wheelchair. The experiments were performed on 15 subjects (13 of them healthy). The BCI is based on steady-state visual-evoked potentials (SSVEP) and the stimuli flickering are performed at high frequency (37, 38, 39 and 40 Hz). This high frequency stimulation scheme can reduce or even eliminate visual fatigue, allowing the user to achieve a stable performance for long term BCI operation. The BCI system uses power-spectral density analysis associated to three bipolar electroencephalographic channels. As the results show, 2 subjects were reported as SSVEP-BCI illiterates (not able to use the BCI), and, consequently, 13 subjects (12 of them healthy) could navigate the wheelchair in a room with obstacles arranged in four distinct configurations. Volunteers expressed neither discomfort nor fatigue due to flickering stimulation. A transmission rate of up to 72.5 bits/min was obtained, with an average of 44.6 bits/min in four trials. These results show that people could effectively navigate a robotic wheelchair using a SSVEP-based BCI with high frequency flickering stimulation.

26 March 2008 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
AFAndre Ferreira
Andre Ferreira
WCWanderley C Celeste
Wanderley C Celeste
FCFernando Auat Cheein
Fernando Auat Cheein
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
MSMário Sarcinelli-Filho
Mário Sarcinelli-Filho
RCRicardo Carelli
Ricardo Carelli
Background: Two different Human-Machine Interfaces (HMIs) were developed, both based on electro-biological signals. One is based on the EMG signal and the other is based on the EEG signal. Two major features of such interfaces are their relatively simple data acquisition and processing systems, which need just a few hardware and software resources, so that they are, computationally and financially speaking, low cost solutions. Both interfaces were applied to robotic systems, and their performances are analyzed here. The EMG-based HMI was tested in a mobile robot, while the EEG-based HMI was tested in a mobile robot and a robotic manipulator as well. Results: Experiments using the EMG-based HMI were carried out by eight individuals, who were asked to accomplish ten eye blinks with each eye, in order to test the eye blink detection algorithm. An average rightness rate of about 95% reached by individuals with the ability to blink both eyes allowed to conclude that the system could be used to command devices. Experiments with EEG consisted of inviting 25 people (some of them had suffered cases of meningitis and epilepsy) to test the system. All of them managed to deal with the HMI in only one training session. Most of them learnt how to use such HMI in less than 15 minutes. The minimum and maximum training times observed were 3 and 50 minutes, respectively. Conclusion: Such works are the initial parts of a system to help people with neuromotor diseases, including those with severe dysfunctions. The next steps are to convert a commercial wheelchair in an autonomous mobile vehicle; to implement the HMI onboard the autonomous wheelchair thus obtained to assist people with motor diseases, and to explore the potentiality of EEG signals, making the EEG-based HMI more robust and faster, aiming at using it to help individuals with severe motor dysfunctions.

10 December 2016 in Sensors
Verified
Journal Article
Open access
PDF file
LVLaura Susana Vargas Valencia
Laura Susana Vargas Valencia
AEArlindo Elias
Arlindo Elias
EREduardo Rocon
Eduardo Rocon
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
ANAnselmo Frizera Neto
Anselmo Frizera Neto
This paper presents a novel calibration procedure as a simple, yet powerful, method to place and align inertial sensors with body segments. The calibration can be easily replicated without the need of any additional tools. The proposed method is validated in three different applications: a computer mathematical simulation; a simplified joint composed of two semi-spheres interconnected by a universal goniometer; and a real gait test with five able-bodied subjects. Simulation results demonstrate that, after the calibration method is applied, the joint angles are correctly measured independently of previous sensor placement on the joint, thus validating the proposed procedure. In the cases of a simplified joint and a real gait test with human volunteers, the method also performs correctly, although secondary plane errors appear when compared with the simulation results. We believe that such errors are caused by limitations of the current inertial measurement unit (IMU) technology and fusion algorithms. In conclusion, the presented calibration procedure is an interesting option to solve the alignment problem when using IMUs for gait analysis.

19 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ABAlexandre Luís Cardoso Bissoli
Alexandre Luís Cardoso Bissoli
DLDaniel Lavino-Junior
Daniel Lavino-Junior
MSMariana Sime
Mariana Sime
Lucas Frizera EncarnaçãoLucas Frizera Encarnação
Lucas Frizera Encarnação
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
People with severe disabilities may have difficulties when interacting with their home devices due to the limitations inherent to their disability. Simple home activities may even be impossible for this group of people. Although much work has been devoted to proposing new assistive technologies to improve the lives of people with disabilities, some studies have found that the abandonment of such technologies is quite high. This work presents a new assistive system based on eye tracking for controlling and monitoring a smart home, based on the Internet of Things, which was developed following concepts of user-centered design and usability. With this system, a person with severe disabilities was able to control everyday equipment in her residence, such as lamps, television, fan, and radio. In addition, her caregiver was able to monitor remotely, by Internet, her use of the system in real time. Additionally, the user interface developed here has some functionalities that allowed improving the usability of the system as a whole. The experiments were divided into two steps. In the first step, the assistive system was assembled in an actual home where tests were conducted with 29 participants without disabilities. In the second step, the system was tested with online monitoring for seven days by a person with severe disability (end-user), in her own home, not only to increase convenience and comfort, but also so that the system could be tested where it would in fact be used. At the end of both steps, all the participants answered the System Usability Scale (SUS) questionnaire, which showed that both the group of participants without disabilities and the person with severe disabilities evaluated the assistive system with mean scores of 89.9 and 92.5, respectively.

14 February 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MRMaria Alejandra Romero-Laiseca
Maria Alejandra Romero-Laiseca
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
VCVivianne Flávia Cardoso
Vivianne Flávia Cardoso
DGDharmendra Gurve
Dharmendra Gurve
FLFlavia Loterio
Flavia Loterio
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
A low-cost Brain-Machine Interface (BMI) based on electroencephalography for lower-limb motor recovery of post-stroke patients is proposed here, which provides passive pedaling as feedback, when patients trigger a Mini-Motorized Exercise Bike (MMEB) by executing pedaling motor imagery (MI). This system was validated in an On-line phase by eight healthy subjects and two post-stroke patients, which felt a closed-loop commanding the MMEB due to the fast response of our BMI. It was developed using methods of low-computational cost, such as Riemannian geometry for feature extraction, Pair-Wise Feature Proximity (PWFP) for feature selection, and Linear Discriminant Analysis (LDA) for pedaling imagery recognition. The On-line phase was composed of two sessions, where each participant completed a total of 12 trials per session executing pedaling MI for triggering the MMEB. As a result, the MMEB was successfully triggered by healthy subjects for almost all trials (ACC up to 100%), while the two post-stroke patients, PS1 and PS2, achieved their best performance (ACC of 41.67% and 91.67%, respectively) in Session #2. These patients improved their latency (2.03 ± 0.42 s and 1.99 ± 0.35 s, respectively) when triggering the MMEB, and their performance suggests the hypothesis that our system may be used with chronic stroke patients for lower-limb recovery, providing neural relearning and enhancing neuroplasticity.