Ana Cecilia Villa-Parra

Ms. Ana Cecilia Villa-Parra

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
JLJessica Lima
Jessica Lima
ANAnselmo Frizera Neto
Anselmo Frizera Neto
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
Robotic devices for rehabilitation and gait assistance have greatly advanced with the objective of improving both the mobility and quality of life of people with motion impairments. To encourage active participation of the user, the use of admittance control strategy is one of the most appropriate approaches, which requires methods for online adjustment of impedance components. Such approach is cited by the literature as a challenge to guaranteeing a suitable dynamic performance. This work proposes a method for online knee impedance modulation, which generates variable gains through the gait cycle according to the users’ anthropometric data and gait sub-phases recognized with footswitch signals. This approach was evaluated in an active knee orthosis with three variable gain patterns to obtain a suitable condition to implement a stance controller: two different gain patterns to support the knee in stance phase, and a third pattern for gait without knee support. The knee angle and torque were measured during the experimental protocol to compare both temporospatial parameters and kinematics data with other studies of gait with knee exoskeletons. The users rated scores related to their satisfaction with both the device and controller through QUEST questionnaires. Experimental results showed that the admittance controller proposed here offered knee support in 50% of the gait cycle, and the walking speed was not significantly different between the three gain patterns (p = 0.067). A positive effect of the controller on users regarding safety during gait was found with a score of 4 in a scale of 5. Therefore, the approach demonstrates good performance to adjust impedance components providing knee support in stance phase.

30 July 2018 in Research on Biomedical Engineering
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
TBThomaz Botelho
Thomaz Botelho
JMJohn Jairo Villarejo Mayor
John Jairo Villarejo Mayor
ADAlberto López Delis
Alberto López Delis
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
Keywords Robotic knee exoskeleton; Electromyography; Trunk muscles; User intention recognition; Admittance control

1 January 2015 in Procedia Manufacturing
Verified
Journal Article
Open access
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
ALA. López-Delis
A. López-Delis
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
Roberto sagaro zamoraRoberto sagaro zamora
Roberto sagaro zamora
ANAnselmo Frizera Neto
Anselmo Frizera Neto
The integration of lower limb exoskeletons with robotic walkers allows obtaining a system to improve mobility and security during gait rehabilitation. In this work, the evaluation of human motion intention (HMI) based on electroencephalogram (EEG) and surface electromyography (sEMG) signals are analyzed for a knee exoskeleton control as a preliminary study for gait neuro-rehabilitation with a hybrid robotic system. This system consists of the knee exoskeleton H2 and the UFES's Smart Walker, which are used to restore the neuromotor control function of subjects with neural injuries. An experimental protocol was developed to identify patterns to control the exoskeleton in accordance with the HMI-based on EEG/sEMG. The EEG and sEMG signals are recorded during the following activities: stand-up/sit-down and knee flexion/extension. HMI is analyzed through both event-related desynchronization/synchronization (ERD/ERS) and slow cortical potential, as well as the myoelectric pattern classification related to lower limb. The feature extraction from sEMG signals is based on vector combinations in time and frequency domain which are used for a pattern classification stage trough an artificial neural network with Levenberg Marquadt training algorithm and support vector machine. Preliminary results shown that a combination of EEG/sEMG signals can be used to define a control strategy for the robotic system

25 November 2017 in Sensors
Verified
Journal Article
Open access
PDF file
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
ALAlberto López-Delis
Alberto López-Delis
ANAnselmo Frizera Neto
Anselmo Frizera Neto
EREduardo Rocon
Eduardo Rocon
This work presents a new on-line adaptive filter, which is based on a similarity analysis between standard electrode locations, in order to reduce artifacts and common interferences throughout electroencephalography (EEG) signals, but preserving the useful information. Standard deviation and Concordance Correlation Coefficient (CCC) between target electrodes and its correspondent neighbor electrodes are analyzed on sliding windows to select those neighbors that are highly correlated. Afterwards, a model based on CCC is applied to provide higher values of weight to those correlated electrodes with lower similarity to the target electrode. The approach was applied to brain computer-interfaces (BCIs) based on Canonical Correlation Analysis (CCA) to recognize 40 targets of steady-state visual evoked potential (SSVEP), providing an accuracy (ACC) of 86.44 ± 2.81%. In addition, also using this approach, features of low frequency were selected in the pre-processing stage of another BCI to recognize gait planning. In this case, the recognition was significantly ( p < 0.01 ) improved for most of the subjects ( A C C ≥ 74.79 % ) , when compared with other BCIs based on Common Spatial Pattern, Filter Bank-Common Spatial Pattern, and Riemannian Geometry.

26 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
JLJessica Lima
Jessica Lima
DRDenis Delisle Rodriguez
Denis Delisle Rodriguez
LVLaura Susana Vargas Valencia
Laura Susana Vargas Valencia
ANAnselmo Frizera Neto
Anselmo Frizera Neto
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
The goal of this study is the assessment of an assistive control approach applied to an active knee orthosis plus a walker for gait rehabilitation. The study evaluates post-stroke patients and healthy subjects (control group) in terms of kinematics, kinetics, and muscle activity. Muscle and gait information of interest were acquired from their lower limbs and trunk, and a comparison was conducted between patients and control group. Signals from plantar pressure, gait phase, and knee angle and torque were acquired during gait, which allowed us to verify that the stance control strategy proposed here was efficient at improving the patients’ gaits (comparing their results to the control group), without the necessity of imposing a fixed knee trajectory. An innovative evaluation of trunk muscles related to the maintenance of dynamic postural equilibrium during gait assisted by our active knee orthosis plus walker was also conducted through inertial sensors. An increase in gait cycle (stance phase) was also observed when comparing the results of this study to our previous work. Regarding the kinematics, the maximum knee torque was lower for patients when compared to the control group, which implies that our orthosis did not demand from the patients a knee torque greater than that for healthy subjects. Through surface electromyography (sEMG) analysis, a significant reduction in trunk muscle activation and fatigability, before and during the use of our orthosis by patients, was also observed. This suggest that our orthosis, together with the assistive control approach proposed here, is promising and could be considered to complement post-stroke patient gait rehabilitation.

8 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
AVAna Cecilia Villa-Parra
Ana Cecilia Villa-Parra
ICIsmael Criollo
Ismael Criollo
CVCarlos Valadão
Carlos Valadão
Leticia SilvaLeticia Silva
Leticia Silva
YCYves Coelho
Yves Coelho
TBTeodiano Bastos-Filho
Teodiano Bastos-Filho
COVID-19 occurs due to infection through respiratory droplets containing the SARS-CoV-2 virus, which are released when someone sneezes, coughs, or talks. The gold-standard exam to detect the virus is Real-Time Polymerase Chain Reaction (RT-PCR); however, this is an expensive test and may require up to 3 days after infection for a reliable result, and if there is high demand, the labs could be overwhelmed, which can cause significant delays in providing results. Biomedical data (oxygen saturation level—SpO2, body temperature, heart rate, and cough) are acquired from individuals and are used to help infer infection by COVID-19, using machine learning algorithms. The goal of this study is to introduce the Integrated Portable Medical Assistant (IPMA), which is a multimodal piece of equipment that can collect biomedical data, such as oxygen saturation level, body temperature, heart rate, and cough sound, and helps infer the diagnosis of COVID-19 through machine learning algorithms. The IPMA has the capacity to store the biomedical data for continuous studies and can be used to infer other respiratory diseases. Quadratic kernel-free non-linear Support Vector Machine (QSVM) and Decision Tree (DT) were applied on three datasets with data of cough, speech, body temperature, heart rate, and SpO2, obtaining an Accuracy rate (ACC) and Area Under the Curve (AUC) of approximately up to 88.0% and 0.85, respectively, as well as an ACC up to 99% and AUC = 0.94, respectively, for COVID-19 infection inference. When applied to the data acquired with the IMPA, these algorithms achieved 100% accuracy. Regarding the easiness of using the equipment, 36 volunteers reported that the IPMA has a high usability, according to results from two metrics used for evaluation: System Usability Scale (SUS) and Post Study System Usability Questionnaire (PSSUQ), with scores of 85.5 and 1.41, respectively. In light of the worldwide needs for smart equipment to help fight the COVID-19 pandemic, this new equipment may help with the screening of COVID-19 through data collected from biomedical signals and cough sounds, as well as the use of machine learning algorithms.