19 February 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
High-performance insulation pull rods are crucial for ensuring the safe and stable operation of gas insulated switchgear (GIS). Currently, light-weight and high-strength aramid fibers serve as the primary reinforcement material in epoxy resin composites for insulation pull rods. However, the smooth surface and low chemical reactivity of aramid fibers severely limit their widespread application. This study proposes using the coordination of Ca2+ to graft fluorine-containing silane coupling agents (AFS) targeted on the surface of aramid fibers, thereby roughening the fiber surface and activating surface activity. This enhances the interfacial bond strength and insulation performance of aramid fiber/epoxy resin (AFEP) composites. The electrical and mechanical properties demonstrate that the flashover voltage, breakdown field strength, and shear strength are increased by 37.97%, 78.47%, and 78.44% respectively. The mechanism whereby Ca2+ coordination targets and enhances the insulation properties of AFEP was elucidated using combined DFT calculations and MD simulations.
15 January 2025 in IEEE Transactions on Power Delivery
Incremental fault diagnosis is an effective way to address the discrepancies between the actual diagnosis data distribution and the trained model. However, the traditional incremental learning method has the problem of forgetting the feature of historical faults and reducing the diagnostic accuracy when applied. A transformer incremental fault diagnosis method using lossless estimation and balanced training is proposed in this study. Firstly, this method achieves lossless estimation of historical task gradients in incremental updates based on Gaussian–Hermite transformation, thereby preserving historical task information as much as possible. Then, to enhance the “anti-forgetting” capability of historical features while ensuring the ability to learn new features, the method balances the weights between the loss functions of new and historical tasks to optimize the update direction of the network training. Finally, the verification results using real data collected from multiple locations indicate that the proposed method has both “anti-forgetting” ability for historical tasks and the ability to learn new tasks effectively. Moreover, the lowest accuracy rate is 97.04% in the test, and the incremental training efficiency is relatively high.
7 April 2025 in IEEE Transactions on Dielectrics and Electrical Insulation
In order to solve the problem of poor prediction of dissolved gas concentration in transformer oil under a defective state caused by a “small-sample” problem, a prediction method for dissolved gas in power transformer oil based on transfer learning and mutation detection is proposed. First, the domain adversarial-transfer learning method is used to train the prediction models under normal and defective states, respectively. A large number of normal state samples are used to assist in training to solve the problem of inaccurate prediction caused by the “small-sample” characteristics of the defective state. Then, taking the prediction error as the criterion, a transformer state mutation detection method is proposed to determine the transformer state for selecting the required model during online prediction. Finally, the online monitoring data of dissolved gas concentration in transformer oil collected on site is used for testing. The results showed that the proposed method can adapt to the prediction tasks under normal and defective states at the same time. Compared with the comparison method, MAPE is reduced by more than 6.504%, and RMSE is reduced by more than $73.295~\mu $ L/L.
20 February 2025 in Physica Scripta
According to the problems of poor insulation and local temperature rise of polypropylene film, a new nano-filler was studied, and the mechanism of improving insulation and thermal conductivity was analyzed. TiO2 with high dielectric constant is combined with Al2O3 with excellent thermal conductivity in the form of a core–shell structure. TiO2 increases the dielectric constant of polypropylene films, and shell Al2O3 introduces high thermal conductivity and assumes the role of dielectric buffer layer. Compared with pure PP, the breakdown voltage of PP/TiO2 is increased by 6.05%, the thermal diffusivty coefficient is increased by 110.67%, the breakdown voltage of PP/TiO2@Al2O3 is increased by 37.05%, and the thermal diffusivity coefficient is increased by 266.85%. Experimental and simulation results show that TiO2 introduces low-density traps, TiO2@Al2O3 introduces high-density deep traps, and Al2O3 modifies the surface defects of high-dielectric nanoparticles and increases the equivalent interface region. Based on the analysis of the experimental results with different mass fractions, this paper proposes the optimal filling ratio of the new core–shell, which provides a new method for the composite dielectric to improve the insulation and thermal conductivity at the same time.
25 June 2026 in Electric Power Systems Research
2 June 2026 in Journal of the Electrochemical Society
Complex correlations among health indicators (HIs) critically impact prediction accuracy, yet existing State-of-Health (SOH) estimation methods struggle to simultaneously model their time-varying coupling relationships and cross-feature dependencies. To address this, this paper proposes an Explicit–Implicit Graph Fusion based Spatiotemporal Graph Convolution Network (EIGF-STGCN). Specifically, regularized graph structure learning is employed to generate sparse implicit graphs for mining latent correlations. These are dynamically fused with explicit mechanism-based prior graphs via self-attention to construct a structure adaptable to degradation evolution. Subsequently, a GCN-TCN model jointly captures spatial dependencies and temporal degradation patterns. Experimental results on NASA and CALCE datasets demonstrate that EIGF-STGCN outperforms LSTM, Transformer, and GCN-TCN. On the NASA dataset, the average MAE and RMSE are reduced by 32.67% and 36.78%, respectively, and by 18.10% and 24.39% on the CALCE dataset. Furthermore, interpretability analysis confirms that the implicit graph uncovers cross-group couplings missed by explicit mechanisms, while the dynamic fusion accurately characterizes time-varying dependencies throughout the lifecycle.