Christine Damases Kasi

Christine Damases Kasi

Auto-generated profile, based on publicly available information

Christine Damases Kasi

The Univ. of Sydney (Australia)

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2020 in Radiology
Verified
Journal Article
Closed access
AGAimilia Gastounioti
Aimilia Gastounioti
CKChristine Damases Kasi
Christine Damases Kasi
CSChristopher Scott
Christopher Scott
KBKathleen R. Brandt
Kathleen R. Brandt
MJMatthew R. Jensen
Matthew R. Jensen
CVCeline Vachon
Celine Vachon
Automated measures by the Laboratory for Individualized Breast Radiodensity Assessment correlated with established area and volumetric density measures and showed comparable breast cancer associati... Background The associations of density measures from the publicly available Laboratory for Individualized Breast Radiodensity Assessment (LIBRA) software with breast cancer have primarily focused o...

1 January 2016 in Academic Radiology
Verified
Journal Article
Closed access
CDChristine N. Damases
Christine N. Damases
PBPatrick C. Brennan
Patrick C. Brennan
CMClaudia Regina Mello-Thoms
Claudia Regina Mello-Thoms
MMMark F McEntee
Mark F McEntee

1 January 2015 in Journal of Medical Imaging
Verified
Journal Article
Open access
PDF file
CDChristine N. Damases
Christine N. Damases
PBPatrick C. Brennan
Patrick C. Brennan
MMMark F McEntee
Mark F McEntee
Mammographic density (MD) is a significant risk factor for breast cancer and has been shown to reduce the sensitivity of mammography screening. Knowledge of a woman’s density can be used to predict her risk of developing breast cancer and personalize her imaging pathway. However, measurement of breast density has proven to be troublesome with wide variations in density recorded using radiologists’ visual Breast Imaging Reporting and Data System (BIRADS). Several automated methods for assessing breast density have been proposed, each with their own source of measurement error. The use of differing mammographic imaging systems further complicates MD measurement, especially for the same women imaged over time. The purpose of this study was to investigate whether having a mammogram on differing manufacturer’s equipment affects a woman’s MD measurement. Raw mammographic images were acquired on two mammography imaging systems (General Electric and Hologic) one year apart and processed using VolparaDensity™ to obtain the Volpara Density Grade (VDG) and average volumetric breast density percentage (AvBD%). Visual BIRADS scores were also obtained from 20 expert readers. BIRADS scores for both systems showed strong positive correlation (ρ=0.904; p<0.001), while the VDG (ρ=0.978; p<0.001) and AvBD% (ρ=0.973; p<0.001) showed stronger positive correlations. Substantial agreement was shown between the systems for BIRADS (κ=0.692; p<0.001), however, the systems demonstrated an almost perfect agreement for VDG (κ=0.933; p<0.001).

1 August 2017 in British Journal of Radiology
Verified
Journal Article
Closed access
CDChristine N. Damases
Christine N. Damases
PHPeter Hogg
Peter Hogg
MMMark F McEntee
Mark F McEntee
Disagreement in mammographic breast density (MBD) assessment can impact breast cancer risk stratification, choices of further breast cancer screening intervals and pathways. This study examines whether inter-country MBD expectations and assessment approaches are associated with differences in MBD assessment. Twenty American Board of Radiology (ABR) examiners and 24 United Kingdom (UK) practitioners using the 4th edition BI-RADS® lexicon assessed 40 mammogram cases of 20 women. Twenty-six Royal Australian and New Zealand College of Radiologists (RANZCR) registered radiologists also assessed the same cases. Inter-observer correlation and agreement were assessed using a Spearman’s correlation (ρ) and weighted Kappa (κw) respectively. Strong positive correlation was observed between the study cohorts on a binary scale (1–2 vs. 3–4) [ABR examiners and RANZCR radiologists (ρ = 0.950); ABR examiners and UK practitioners (ρ = 0.940); RANZCR radiologists and UK practitioners (ρ = 0.958)]. ABR and RANZCR radiologists demonstrated slight agreement [κw = 0.10; 95% CI = -1.13 - 0.43] while ABR and UK practitioners showed a fair agreement [κw = 0.25; 95% CI = -0.42 - 0.61], and an almost perfect agreement was observed between RANZCR radiologists and UK practitioners [κw = 0.95; 95% CI = 0.91 - 0.97]. Findings demonstrate wide international and inter-observer variability in MBD assessment. This level of variability underscores the need for automation and standardisation of MBD assessment. Inter country analysis of mammographic breast density assessment shows variations, with less variation on binary scale than on 4-point scale. With this level of variation automation and standardisation of mammographic breast density assessment becomes more appropriate.

5 April 2016 in Journal of Medical Imaging and Radiation Oncology
Verified
Journal Article
Closed access
PDF file
CDChristine N Damases
Christine N Damases
CMClaudia Regina Mello-Thoms
Claudia Regina Mello-Thoms
MMMark F McEntee
Mark F McEntee