Background: Breast cancer is the most common occurring cancer in women worldwide. To guide current breast cancer screening program, the level of knowledge about breast cancer should be evaluated. This study aims to ascertain the level of breast cancer knowledge including risk factors, signs and symptoms, and early detection methods, especially mammography screening. Methods: The study was conducted among 1353 Jordanian women from the public using a self-administered questionnaire. Responses to the knowledge test were summed for an overall knowledge score. Comparisons between socio-demographics and knowledge, attitude and practice were also measured using a Chi-square test. Results: About 76% of participants were aware that breast cancer is the most common cancer among women in Jordan. About 53.7% of our participants were rated as having an intermediate level of knowledge regarding risk factors, and 44% were rated as having a good to an excellent level of knowledge about breast cancer signs and symptoms. The participants’ level of education was the main factor identified as influencing the participants’ knowledge of the risk factors, signs and symptoms, and knowledge of early detection methods of breast cancer. The study sample was rated as having an intermediate level of knowledge regarding mammography screening; however, their participation in this screening method was low. Conclusion: Although Jordanian women had an acceptable level of knowledge of breast cancer, the screening rates for mammography were low. These findings suggest that there is a need to provide extra awareness programs for Jordanian women to improve their breast cancer knowledge and practice.
Our objective was to analyze the agreement between organ dose estimated by different digital mammography units and calculated dose for clinical data. Digital Imaging and Communication in Medicine header information was extracted from 52,405 anonymized mammograms. Data were filtered to include images with no breast implants, breast thicknesses 20 to 110 mm, and complete exposure and quality assurance data. Mean glandular dose was calculated using methods by Dance et al., Wu et al., and Boone et al. Bland–Altman analysis and regression were used to study the agreement and correlation between organ and calculated doses. Bland–Altman showed statistically significant bias between organ and calculated doses. The bias differed for different unit makes and models; Philips had the lowest bias, overestimating Dance method by 0.03 mGy, while general electric had the highest bias, overestimating Wu method by 0.20 mGy, the Hologic organ dose underestimated Boone method by 0.07 mGy, and the Fujifilm organ dose underestimated Dance method by 0.09 mGy. Organ dose was found to disagree with our calculated dose, yet organ dose is potentially beneficial for rapid dose audits. Conclusions drawn based on the organ dose alone come with a risk of over or underestimating the calculated dose to the patient and this error should be considered in any reported results.
The Imaging and Medical Beamline (IMBL) is a superconducting multipole wiggler-based beamline at the 3 GeV Australian Synchrotron operated by the Australian Nuclear Science and Technology Organisation (ANSTO). The beamline delivers hard X-rays in the 25–120 keV energy range and offers the potential for a range of biomedical X-ray applications, including radiotherapy and medical imaging experiments. One of the imaging modalities available at IMBL is propagation-based X-ray phase-contrast computed tomography (PCT). PCT produces superior results when imaging low-density materials such as soft tissue (e.g., breast mastectomies) and has the potential to be developed into a valuable medical imaging tool. We anticipate that PCT will be utilized for medical breast imaging in the near future with the advantage that it could provide better contrast than conventional X-ray absorption imaging. The unique properties of synchrotron X-ray sources such as high coherence, energy tunability, and high brightness are particularly well-suited for generating PCT data using very short exposure times on the order of less than 1 min. The coherence of synchrotron radiation allows for phase-contrast imaging with superior sensitivity to small differences in soft-tissue density. Here we also compare the results of PCT using two different detectors, as these unique source characteristics need to be complemented with a highly efficient detector. Moreover, the application of phase retrieval for PCT image reconstruction enables the use of noisier images, potentially significantly reducing the total dose received by patients during acquisition. This work is part of ongoing research into innovative tomographic methods aimed at the introduction of 3D X-ray medical imaging at the IMBL to improve the detection and diagnosis of breast cancer. Major progress in this area at the IMBL includes the characterization of a large number of mastectomy samples, both normal and cancerous, which have been scanned at clinically acceptable radiation dose levels and evaluated by expert radiologists with respect to both image quality and cancer diagnosis.
Visual search, the process of detecting and identifying objects using eye movements (saccades) and foveal vision, has been studied for identification of root causes of errors in the interpretation of mammograms. The aim of this study is to model visual search behavior of radiologists and their interpretation of mammograms using deep machine learning approaches. Our model is based on a deep convolutional neural network, a biologically inspired multilayer perceptron that simulates the visual cortex and is reinforced with transfer learning techniques. Eye-tracking data were obtained from eight radiologists (of varying experience levels in reading mammograms) reviewing 120 two-view digital mammography cases (59 cancers), and it has been used to train the model, which was pretrained with the ImageNet dataset for transfer learning. Areas of the mammogram that received direct (foveally fixated), indirect (peripherally fixated), or no (never fixated) visual attention were extracted from radiologists’ visual search maps (obtained by a head mounted eye-tracking device). These areas along with the radiologists’ assessment (including confidence in the assessment) of the presence of suspected malignancy were used to model: (1) radiologists’ decision, (2) radiologists’ confidence in such decisions, and (3) the attentional level (i.e., foveal, peripheral, or none) in an area of the mammogram. Our results indicate high accuracy and low misclassification in modeling such behaviors.
13 August 2018 in Journal of Synchrotron Radiation