Matteo Tropeano

Matteo Tropeano

Auto-generated profile, based on publicly available information

Matteo Tropeano

ASG Superconductors S.p.A., Genova, Italy

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2009 in Physical Review B
Verified
Journal Article
Open access
PDF file
MTM. Tropeano
M. Tropeano
CFCarlo Fanciulli
Carlo Fanciulli
FCFabio Canepa
Fabio Canepa
MCM. R. Cimberle
M. R. Cimberle
CFCarlo Ferdeghini
Carlo Ferdeghini
APA. Palenzona
A. Palenzona
We present a study concerning the partial substitution of yttrium at the lanthanum site of the undoped LaFeAsO and superconducting LaFeAsO0.85F0.15 compounds. We prepared samples with a nominal yttrium content up to 70% producing simultaneous shrinkage of both the a- and c-lattice parameters by 1.8% and 1.7%, respectively. The chemical pressure provided by the partial substitution with this smaller ion size causes a lowering of the spin density wave temperature in the undoped compounds, as well as an increase in the superconducting transition temperatures in the doped ones. The 15% fluorine-doped samples reach a maximum critical temperature of 40.2 K for the 50% yttrium substitution. Comparison with literature data indicates that chemical pressure cannot be the only mechanism which tunes drastically both TSDW and Tc in 1111 compounds. Our data suggest that the structural disorder induced by the partial substitution in the La site or by doping could play an important role as well.

3 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
CBChristian E. Bruzek
Christian E. Bruzek
TSTiziana Spina
Tiziana Spina
UMUmberto Melaccio
Umberto Melaccio
MTMatteo Tropeano
Matteo Tropeano
AMAdela Marian
Adela Marian
NMNiklas Magnusson
Niklas Magnusson
The combination of liquid hydrogen and superconducting cables presents a unique opportunity to distribute both hydrogen and bulk electricity in the same infrastructure. In particular, liquid hydrogen around 20 K is ideally suited for cooling the MgB 2 superconductor, resulting in a compact power cable that also leaves sufficient place for the hydrogen flow. Such a hybrid system operating in the MVDC range at 25 kV and 20 kA constitutes one of the main goals of the European project SCARLET. After a description of the rationale and benefits of the electricity – hydrogen system, various possible applications and a first distribution system are presented. Furthermore, the different cable components already designed are discussed along with the research challenges and general strategy for the development.

12 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
TSTiziana Spina
Tiziana Spina
AAAlberto Ansaldo
Alberto Ansaldo
ATAndrea Tumino
Andrea Tumino
MPMauceri Paola
Mauceri Paola
SPSimone Pasini
Simone Pasini
GGGiovanni Grasso
Giovanni Grasso
Nowadays, ex-situ Powder-In-Tube (PIT) MgB 2 multifilamentary wires are commercially available in long length and can reach self-field critical current (I c ) values above 1000 A at 20 K; moreover, thanks to its high critical temperature T c (38 K) such wires are good candidates for cryogen-free applications and devices required for the future. In the past, MRI system has already profited from these advantages and turned out to a series production of open MRI systems. Recently, this type of conductor has been chosen in the European project SCARLET for demonstrating the feasibility of a 500 MW DC monopolar cable system transferring 20 kA at 25 kV and, at the same time, distributes LH 2 . In addition, MgB 2 is the most lightweight superconductor among the realm of practical superconductors, thus to be also suitable for aircraft components. In this work, the current state-of-the-art of the commercial ex-situ PIT MgB 2 wires at ASG superconductors is reported and perspectives and challenges for their improvements over the next years is discussed.

27 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
Laura SavoldiLaura Savoldi
Laura Savoldi
ABAlessandro Balbo
Alessandro Balbo
CBChristian E. Bruzek
Christian E. Bruzek
GGGianni Grasso
Gianni Grasso
MPMatteo Patti
Matteo Patti
MTMatteo Tropeano
Matteo Tropeano
The design of a single-pole MgB 2 superconducting hydrogen-cooled cable for DC current transmission at low voltage (10 kV) is presented here. The cable consists of a former made of MgB 2 superconducting wires, a dielectric layer and an annular region that allows for the passage of hydrogen at inlet pressures above the critical one. The cable is contained within a corrugated cryostat, insulated from the external environment. The use of MgB 2 as a superconducting material allows for the operation of the cable in the range 15-27 K, which reduces the cooling requirements and increases the efficiency of the system. The hydrogen-cooled annular region, acting as a pipeline for the cryogen transport, allows at the same time the efficient cooling of the cable, while the corrugated cryostat provides additional insulation and structural support, together with a relief volume in the case of an accident. The results of this study, mainly performed with a simplified model, benchmarked against the OPENSC2 software, show that the cable is able to support DC current transmission at 10 kV, with maximum cable lengths of several tens of km for inner diameters of the cryostat > 120 mm, supporting a H 2 mass flow rate > 1 kg/s. Overall, this study demonstrates the feasibility of combining the DC current transmission at low-medium voltage by MgB 2 to the transport of liquid hydrogen, providing at the same time instantaneous storage of chemical power.

21 November 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MTMatteo Tropeano
Matteo Tropeano
LSLuca Soldati
Luca Soldati
AAAlberto Ansaldo
Alberto Ansaldo
CBChristian-Eric Bruzek
Christian-Eric Bruzek
GGGiovanni Grasso
Giovanni Grasso
ATAndrea Tumino
Andrea Tumino
The MgB2 wire manufacturing process at ASG Superconductors has reached a high level of maturity in terms of reproducibility and homogeneity of long length superconducting wires and tapes, available with different size and layout configuration in single unit length up to 6–7 km. Due to the good mechanical properties, tuned by the selection of the materials used as sheaths, and by the final heat treatment parameters, the reacted wires are well suitable for magnet winding and cable manufacturing using industrial machinery. Thanks to these characteristics, MgB2 technology covers a wide range of potential applications: magnets for MRI systems, accelerators and detectors, as well as cable for transmission-distribution network and bus-bars for industrial or fusion applications. Furthermore, the affordable cost and the possibility to use liquid hydrogen as coolant, make MgB2 wires, the most suitable solution to implement superconductivity as a mean to address low carbon and energy transition challenges. In this report, the status of the MgB2 wires manufacturing will be presented, giving an overview of the available wire characteristics and their current and future implementation in magnet and cable applications.

5 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
Antonio MorandiAntonio Morandi
Antonio Morandi
MFMassimo Fabbri
Massimo Fabbri
PRPier Luigi Ribani
Pier Luigi Ribani
Francesco Lo FrancoFrancesco Lo Franco
Francesco Lo Franco
Riccardo MandrioliRiccardo Mandrioli
Riccardo Mandrioli
CGChiara Gandolfi
Chiara Gandolfi
SMES technology based on MgB2 superconductor and cryogenic-free cooling can offer a viable solution to power-intensive storage in the short term. One of the main obstacles to the development of dry-cooled SMES systems is the heat load removal due to the AC loss of the superconductor during fast charging and discharging cycles at high power. Accurate knowledge of the amount and distribution of AC loss in the coil is of paramount importance for the sizing and the design of the cooling system and for assessing the possible operational limits of the technology. In this manuscript, the AC loss of a 500 kJ/200 kW multifilamentary MgB2 SMES during charge–discharge cycling at full power is numerically investigated. The methodology and assumptions of the calculation are briefly resumed, and numerical results are reported and discussed in detail. In particular, the time profile and the distribution of the dissipated power all over the coil are reported. An average dissipation of 85.5 mW/m is found all over the coil during one charge–discharge cycle at full power, with a peak of 150.1 mW/m in the turns lying at the ends of the coil.