Patrick Schuenke

Patrick Schuenke

Auto-generated profile, based on publicly available information

Patrick Schuenke

Physikalisch‐Technische Bundesanstalt (PTB) Braunschweig and Berlin Germany

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2018 in Neuro-Oncology
Verified
Journal Article
Open access
PDF file
Daniel PaechDaniel Paech
Daniel Paech
JWJohannes Windschuh
Johannes Windschuh
JOJohanna Oberhollenzer
Johanna Oberhollenzer
CDConstantin Dreher
Constantin Dreher
FSFelix Sahm
Felix Sahm
ARAlexander Radbruch
Alexander Radbruch
Early identification of prognostic superior characteristics in glioma patients such as isocitrate dehydrogenase (IDH) mutation and O6-methylguanine-DNA-methyltransferase (MGMT) promoter methylation status is of great clinical importance. The study purpose was to investigate the non-invasive predictability of IDH mutation status, MGMT promoter methylation, and differentiation of low-grade versus high-grade glioma (LGG vs HGG) in newly diagnosed patients employing relaxation-compensated multipool chemical exchange saturation transfer (CEST) MRI at 7.0 Tesla. Thirty-one patients with newly diagnosed glioma were included in this prospective study. CEST MRI was performed at a 7T whole-body scanner. Nuclear Overhauser effect (NOE) and isolated amide proton transfer (APT; downfield NOE-suppressed APT = dns-APT) CEST signals (mean value and 90th signal percentile) were quantitatively investigated in the whole tumor area with regard to predictability of IDH mutation, MGMT promoter methylation status, and differentiation of LGG versus HGG. Statistics were performed using receiver operating characteristic (ROC) and area under the curve (AUC) analysis. Results were compared with advanced MRI methods (apparent diffusion coefficient and relative cerebral blood volume ROC/AUC analysis) obtained at 3T. dns-APT CEST yielded highest AUCs in IDH mutation status prediction (dns-APTmean = 91.84%, P < 0.01; dns-APT90 = 97.96%, P < 0.001). Furthermore, dns-APT metrics enabled significant differentiation of LGG versus HGG (AUC: dns-APTmean = 0.78, P < 0.05; dns-APT90 = 0.83, P < 0.05). There was no significant difference regarding MGMT promoter methylation status at any contrast (P > 0.05). Relaxation-compensated multipool CEST MRI, particularly dns-APT imaging, enabled prediction of IDH mutation status and differentiation of LGG versus HGG and should therefore be considered as a non-invasive MR biomarker in the diagnostic workup.

15 December 2014 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
MZMoritz Zaiss
Moritz Zaiss
ZZZhongliang Zu
Zhongliang Zu
JXJunzhong Xu
Junzhong Xu
PSPatrick Schuenke
Patrick Schuenke
DGDaniel F. Gochberg
Daniel F. Gochberg
PBPeter Bachert
Peter Bachert

9 February 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PSPatrick Schuenke
Patrick Schuenke
JWJohannes Windschuh
Johannes Windschuh
VRVolkert Roeloffs
Volkert Roeloffs
MLMark E. Ladd
Mark E. Ladd
PBPeter Bachert
Peter Bachert
MZMoritz Zaiss
Moritz Zaiss

1 December 2017 in Radiology
Verified
Journal Article
Closed access
Daniel PaechDaniel Paech
Daniel Paech
PSPatrick Schuenke
Patrick Schuenke
CKChristina Koehler
Christina Koehler
JWJohannes Windschuh
Johannes Windschuh
SMSibu Mundiyanapurath
Sibu Mundiyanapurath
ARAlexander Radbruch
Alexander Radbruch
T1ρ-weighted dynamic glucose-enhanced contrast can be obtained with sufficient sensitivity and temporal resolution to quantitatively image brain glucose physiology in healthy humans and pathophysiologically increased glucose uptake of tumors in patients with glioblastoma at 7.0 T. PurposeTo evaluate the ability to detect intracerebral regions of increased glucose concentration at T1ρ-weighted dynamic glucose-enhanced (DGE) magnetic resonance (MR) imaging at 7.0 T.Materials and MethodsThis prospective study was approved by the institutional review board. Nine patients with newly diagnosed glioblastoma and four healthy volunteers were included in this study from October 2015 to July 2016. Adiabatically prepared chemical exchange–sensitive spin-lock imaging was performed with a 7.0-T whole-body unit with a temporal resolution of approximately 7 seconds, yielding the time-resolved DGE contrast. T1ρ-weighted DGE MR imaging was performed with injection of 100 mL of 20% d-glucose via the cubital vein. Glucose enhancement, given by the relative signal intensity change at T1ρ-weighted MR imaging (DGEρ), was quantitatively investigated in brain gray matter versus white matter of healthy volunteers and in tumor tissue versus normal-appearing white matter of patients with glioblastoma. The med...

13 August 2016 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
PSPatrick Schuenke
Patrick Schuenke
CKChristina Koehler
Christina Koehler
AKAndreas Korzowski
Andreas Korzowski
JWJohannes Windschuh
Johannes Windschuh
PBPeter Bachert
Peter Bachert
MZMoritz Zaiss
Moritz Zaiss

7 May 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KHKai Herz
Kai Herz
SMSebastian Mueller
Sebastian Mueller
Or PerlmanOr Perlman
Or Perlman
MZMaxim Zaitsev
Maxim Zaitsev
LKLinda Knutsson
Linda Knutsson
MZMoritz Zaiss
Moritz Zaiss
Purpose: As the field of CEST grows, various novel preparation periods using different parameters are being introduced. At the same time, large, multisite clinical studies require clearly defined protocols, especially across different vendors. Here, we propose a CEST definition standard using the open Pulseq format for a shareable, simple, and exact definition of CEST protocols.Methods: We present the benefits of such a standard in three ways: (1) an open database on GitHub, where fully defined, human‐readable CEST protocols can be shared; (2) an open‐source Bloch‐McConnell simulation to test and optimize CEST preparation periods in silico; and (3) a hybrid MR sequence that plays out the CEST preparation period and can be combined with any existing readout module.Results: The exact definition of the CEST preparation period, in combination with the flexible simulation, leads to a good match between simulations and measurements. The standard allowed finding consensus on three amide proton transfer–weighted protocols that could be compared in healthy subjects and a tumor patient. In addition, we could show coherent multisite results for a sophisticated CEST method, highlighting the benefits regarding protocol sharing and reproducibility.Conclusion: With Pulseq‐CEST, we provide a straightforward approach to standardize, share, simulate, and measure different CEST preparation schemes, which are inherently completely defined.