Augustine Urbas

Augustine Urbas

Auto-generated profile, based on publicly available information

Augustine Urbas

Air Force Research Lab. (United States)

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2008 in Journal of the Optical Society of America A
Verified
Journal Article
Closed access
PDF file
RSRichard L. Sutherland
Richard L. Sutherland
LMLydia M. Mäthger
Lydia M. Mäthger
RHRoger T. Hanlon
Roger T. Hanlon
AUAugustine M. Urbas
Augustine M. Urbas
MSMorley O. Stone
Morley O. Stone
A mathematical model of multiple layer skin coloration in cephalopods, a class of aquatic animals, is presented. The model incorporates diffuse and specular reflection from both pigment and structural photonic components found in the skin of these animals. Specific physical processes of this coloration are identified and modeled utilizing available biological materials data. Several examples of combination spectra are calculated to illustrate multiple layer and incident light effects as well as the potentially rich repertoire of color schemes available to these animals. A detailed understanding of the physical principles underlying cephalopod coloration is expected to yield insights into their possible functions.

23 May 2012 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
JVJarrett H. Vella
Jarrett H. Vella
AUAugustine M. Urbas
Augustine M. Urbas

1 July 2003 in Applied Optics
Verified
Journal Article
Closed access
PDF file
LGLori S. Goldner
Lori S. Goldner
MFMichael J. Fasolka
Michael J. Fasolka
SNSophie Nougier
Sophie Nougier
HNHoang-Phi Nguyen
Hoang-Phi Nguyen
GBGarnett W. Bryant
Garnett W. Bryant
ETEdwin L. Thomas
Edwin L. Thomas
We present measurements of the local diattenuation and retardance of thin-film specimens by using techniques that combine near-field scanning optical microscopy (NSOM) and a novel polarization-modulation (PM) polarimetry utilizing Fourier analysis of the detected intensity signal. Generally, quantitative near-field polarimetry is hampered by the optical anisotropy of NSOM probes. For example, widely used aluminum-coated pulled-fiber aperture probes typically exhibit a diattenuation near 10%. Our analysis of aperture diattenuation demonstrates that the usual techniques for nulling a PM polarimeter result in a nonzero residual probe retardance in the presence of a diattenuating tip. However, we show that both diattenuation and retardance of the sample can be determined if the corresponding tip properties are explicitly measured and accounted for in the data. In addition, in thin films (<100 nm thick), where the sample retardance and diattenuation are often small, we show how to determine these polarimetric quantities without requiring alignment of the fast and diattenuating axes, which is a more general case than has been previously discussed. We demonstrate our techniques by using two types of polymer-film specimens: ultrahigh molecular weight block copolymers (recently noted for their photonic activity) and isotactic polystyrene spherulites. Finally, we discuss how changes in the tip diattenuation during data collection can limit the accuracy of near-field polarimetry and what steps can be taken to improve these techniques.

1 June 2017
Verified
Conference Paper
Closed access
DMD. B. Megherbi
D. B. Megherbi
JDJ. DiZoglio
J. DiZoglio
PMP. Mack
P. Mack
MVM. I. Vakil
M. I. Vakil
NLN. Limberopoulos
N. Limberopoulos
AUA. Urbas
A. Urbas
In this paper we focus on using signal processing techniques and mathematically-derived photo-detector models, with or without microsphere-lens-enhancement, to analyze, characterize and estimate the effect of integrated aberrations on microsphere-lens-enhanced single photo-detector sensitivity. One of the difficulties here relates to the noisy nature of detector FTIR experimental signals in the MWIR band. We show how modeling of the detector spectral response signal, combined with signal boundary-absorption partial replacement, is successfully effective in estimating integrated detector system aberrations. With the detector FTIR spectral data, considered, our findings show that (a) not all four microsphere materials, considered in this work, namely, Sapphire, SLG (Soda, Lime Glass), PS (Polystyrene) and BTG (Barium Titanate Glass) necessarily result in detector sensitivity increase at all MWIR wavelengths. The PS-microsphere-lens-enhanced detector sensitivity turns out to be less than that of the detector without enhancement in the 2700-3200 wavenumber band. This is due to the fact at this band the PS material exhibits additional significant spectral absorptions. (b) there seems to exist some global detector integrated aberrations introduced by factors such as the microsphere lens material and misalignment, silicone-or-rubber adhesive material, photo-detector system and others, that we globally extracted/estimated using the detector experimental FTIR spectral responses and their corresponding generated detector mathematical models. (c) comparison of single detector raw experimental spectral responses (with and without microsphere-lenses of different sizes and material types) to their respective resulting models, shows realistic synthesized detector FTIR data models. With the help of theses resulting detector FTIR response models, we are able to confirm our findings that, relatively independently of the increase in the sensitivity, the microsphere lens significantly decreases the sphere-enhanced-detector Noise to Signal Ratio (NSR), including in spectral bands of high absorption, noise, and aberration. That is, based on the data considered, (1) the resulting microsphere-enhanced photo-detector is generally less sensitive to noise in the MWIR than the mesa and (2) this, seemingly is so, independently of the detector sensitivity increase, for example, due to the microsphere size of a certain material type.

1 June 2017
Verified
Conference Paper
Closed access
DMD. B. Megherbi
D. B. Megherbi
PMP. Mack
P. Mack
JDJ. DiZoglio
J. DiZoglio
MVM. I. Vakil
M. I. Vakil
NLN. Limberopoulos
N. Limberopoulos
AUA. Urbas
A. Urbas
In our prior work we have analyzed, proposed global performance metrics, and shown how MWIR microsphere lens-enhanced single detectors have exhibited an increase in detector sensitivity and reduction in Noise to Signal Ratio (NSR). We have shown that, in general, the microsphere lens reduces the detector NSR independently of the increase in the enhanced detector sensitivity. We have also shown how microsphere lens material absorptions and misalignments can affect and reduce the microsphere lens-enhanced MWIR detector sensitivity. When placing a microsphere lens on a photo-detector, usually an optical silicone-or rubber adhesive is used to adhere and hold the microsphere lens on the single photo-detector. In this paper, we present a novel hybrid model-based and experimental data driven-based technique for analysis and characterization of the effect of the adhesive material on microsphere-lens-enhanced SLS single photo-detector sensitivity. In this work these adhesive material characteristics are modeled and compared to experimental microsphere-enhanced single detector FTIR spectral data. As we demonstrate here, based on the data considered, the results show that the adhesive material appears to adversely affect and decrease the detector overall sensitivity, and in some instances, by more than 40% depending on the adhesive material index of refraction, even with a high adhesive material transmittance/transparency.