Nicholaos Limberopoulos

Nicholaos Limberopoulos

Auto-generated profile, based on publicly available information

Nicholaos Limberopoulos

Air Force Research Laboratory, Sensors Directorate, Wright-Patterson AFB, OH 45433

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2018 in IEEE Photonics Journal
Verified
Journal Article
Open access
ASAndrew Sarangan
Andrew Sarangan
JDJosh Duran
Josh Duran
VVVladimir Vasilyev
Vladimir Vasilyev
NLNicholaos Limberopoulos
Nicholaos Limberopoulos
IVIlya Vitebskiy
Ilya Vitebskiy
IAIgor Anisimov
Igor Anisimov
We experimentally demonstrate a thermally induced reflective optical limiter using Ge 2 Sb 2 Te 5 (GST) and SiO 2 in a multilayer photonic bandgap edge-filter configuration. In the PASS state, greater than 80% transmission was achieved at λ ~ 1500 nm over a 300 nm spectral bandwidth and ±45° angles of incidence. In the BLOCK state, extinction ratios higher than 30 dB were achieved. By comparison, all previous optical limiters based on nonlinear photonic crystals have severe spectral bandwidth and/or angle of incidence limitations in either the PASS or BLOCK states. A nine-layer implementation of this device was fabricated and tested in this paper. Numerical modeling results show reasonable agreement with measured values. To the best of our knowledge, this is the first demonstration of optical limiting over a broad spectral band using phase change materials with this level of performance. However, it should be noted that although GST can be switched in both directions, the experimental results demonstrated in this paper are limited to PASS-to-BLOCK switching only.

20 June 2016 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
JVJarrett H. Vella
Jarrett H. Vella
JGJohn H. Goldsmith
John H. Goldsmith
ABAndrew T. Browning
Andrew T. Browning
NLNicholaos I. Limberopoulos
Nicholaos I. Limberopoulos
IVIlya Vitebskiy
Ilya Vitebskiy
TKTsampikos Kottos
Tsampikos Kottos
Optical limiters transmit low-intensity light, while blocking laser radiation with excessively high irradiance or fluence. A typical optical limiter involves a nonlinear material which is transparent at low light intensity and becomes opaque when the light intensity exceeds a certain level. Most of the high-level radiation is absorbed by the nonlinear material causing irreversible damage. This fundamental problem could be solved if the state of the nonlinear material changed from transparent to highly reflective (not absorptive) when the intensity becomes too high. None of the known nonlinear optical materials display such a property. A solution can be provided by a nonlinear photonic structure. In this communication, we report the experimental realization of a reflective optical limiter. The design is based on a planar microcavity composed of alternating SiO2 and Si3N4 layers with a single GaAs defect layer in the middle. At low intensity, the planar microcavity displays a strong resonant transmission via a cavity mode. As the intensity increases, two-photon absorption in GaAs kicks in, initially resulting in the microcavity-enhanced light absorption. A further increase in light intensity, though, suppresses the cavity mode along with the resonant transmission; the entire planar microcavity turns highly reflective within a broad frequency range covering the entire photonic band gap. This seemingly counterintuitive behavior is a general feature of resonant transmission via a cavity mode with purely nonlinear absorption.

8 June 2018 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
BTBrian B. Tierney
Brian B. Tierney
NLNicholaos I. Limberopoulos
Nicholaos I. Limberopoulos
RERobert L. Ewing
Robert L. Ewing
AGAnthony Grbic
Anthony Grbic
A broadband, 7-port beamformer is designed and fabricated using printed-circuit, tensor transmission-line metamaterials. The beamformer is first modeled as a 2D medium with an unknown inhomogeneous, anisotropic material distribution: scalar permittivity ϵ(x, y) and tensor permeability μ(x, y). Then, a recently-developed optimization procedure is employed to determine ϵ(x, y) and μ(x, y) and subsequently realized using tensor transmission-line metamaterials. The beamformer is designed to switch beams in 10° increments from -30° to 30° in azimuth, over a broad range of frequencies. Measurement results exhibit good agreement with the prescribed design goals. The reported beamformer offers several advantages compared to traditional beamformers, including the stipulation of arbitrary output fields, flat input/output interfaces, and broad bandwidth performance.

23 February 2017
Verified
Conference Paper
Closed access
PDF file
VAV. N. Astratov
V. N. Astratov
AMA. V. Maslov
A. V. Maslov
ABA. Brettin
A. Brettin
KBK. F. Blanchette
K. F. Blanchette
YNYuri Nesmelov
Yuri Nesmelov
AUA. M. Urbas
A. M. Urbas

1 June 2017
Verified
Conference Paper
Closed access
DMD. B. Megherbi
D. B. Megherbi
JDJ. DiZoglio
J. DiZoglio
PMP. Mack
P. Mack
MVM. I. Vakil
M. I. Vakil
NLN. Limberopoulos
N. Limberopoulos
AUA. Urbas
A. Urbas
In this paper we focus on using signal processing techniques and mathematically-derived photo-detector models, with or without microsphere-lens-enhancement, to analyze, characterize and estimate the effect of integrated aberrations on microsphere-lens-enhanced single photo-detector sensitivity. One of the difficulties here relates to the noisy nature of detector FTIR experimental signals in the MWIR band. We show how modeling of the detector spectral response signal, combined with signal boundary-absorption partial replacement, is successfully effective in estimating integrated detector system aberrations. With the detector FTIR spectral data, considered, our findings show that (a) not all four microsphere materials, considered in this work, namely, Sapphire, SLG (Soda, Lime Glass), PS (Polystyrene) and BTG (Barium Titanate Glass) necessarily result in detector sensitivity increase at all MWIR wavelengths. The PS-microsphere-lens-enhanced detector sensitivity turns out to be less than that of the detector without enhancement in the 2700-3200 wavenumber band. This is due to the fact at this band the PS material exhibits additional significant spectral absorptions. (b) there seems to exist some global detector integrated aberrations introduced by factors such as the microsphere lens material and misalignment, silicone-or-rubber adhesive material, photo-detector system and others, that we globally extracted/estimated using the detector experimental FTIR spectral responses and their corresponding generated detector mathematical models. (c) comparison of single detector raw experimental spectral responses (with and without microsphere-lenses of different sizes and material types) to their respective resulting models, shows realistic synthesized detector FTIR data models. With the help of theses resulting detector FTIR response models, we are able to confirm our findings that, relatively independently of the increase in the sensitivity, the microsphere lens significantly decreases the sphere-enhanced-detector Noise to Signal Ratio (NSR), including in spectral bands of high absorption, noise, and aberration. That is, based on the data considered, (1) the resulting microsphere-enhanced photo-detector is generally less sensitive to noise in the MWIR than the mesa and (2) this, seemingly is so, independently of the detector sensitivity increase, for example, due to the microsphere size of a certain material type.

1 June 2017
Verified
Conference Paper
Closed access
DMD. B. Megherbi
D. B. Megherbi
PMP. Mack
P. Mack
JDJ. DiZoglio
J. DiZoglio
MVM. I. Vakil
M. I. Vakil
NLN. Limberopoulos
N. Limberopoulos
AUA. Urbas
A. Urbas
In our prior work we have analyzed, proposed global performance metrics, and shown how MWIR microsphere lens-enhanced single detectors have exhibited an increase in detector sensitivity and reduction in Noise to Signal Ratio (NSR). We have shown that, in general, the microsphere lens reduces the detector NSR independently of the increase in the enhanced detector sensitivity. We have also shown how microsphere lens material absorptions and misalignments can affect and reduce the microsphere lens-enhanced MWIR detector sensitivity. When placing a microsphere lens on a photo-detector, usually an optical silicone-or rubber adhesive is used to adhere and hold the microsphere lens on the single photo-detector. In this paper, we present a novel hybrid model-based and experimental data driven-based technique for analysis and characterization of the effect of the adhesive material on microsphere-lens-enhanced SLS single photo-detector sensitivity. In this work these adhesive material characteristics are modeled and compared to experimental microsphere-enhanced single detector FTIR spectral data. As we demonstrate here, based on the data considered, the results show that the adhesive material appears to adversely affect and decrease the detector overall sensitivity, and in some instances, by more than 40% depending on the adhesive material index of refraction, even with a high adhesive material transmittance/transparency.