Nikta Pournoori

Nikta Pournoori

Auto-generated profile, based on publicly available information

Nikta Pournoori

Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2021 in International Journal of Antennas and Propagation
Verified
Journal Article
Open access
PDF file
NPNikta Pournoori
Nikta Pournoori
LSLauri Sydänheimo
Lauri Sydänheimo
YRYahya Rahmat-Samii
Yahya Rahmat-Samii
LULeena Ukkonen
Leena Ukkonen
TBToni Björninen
Toni Björninen
We present a meandered triple-band planar-inverted-F antenna (PIFA) for integration into brain-implantable biotelemetric systems. The target applications are wireless data communication, far-field wireless power transfer, and switching control between sleep/wake-up mode at the Medical Device Radiocommunication Service (MedRadio) band (401406MHz) and Industrial, Scientific and Medical (ISM) bands (902928MHz and 24002483.5MHz), respectively. By embedding meandered slots into the radiator and shorting it to the ground, we downsized the antenna to the volume of 11×20.5×1.8mm3. We optimized the antenna using a 7-layer numerical human head model using full-wave electromagnetic field simulation. In the simulation, we placed the implant in the cerebrospinal fluid (CSF) at a depth of 13.25mm from the body surface, which is deeper than in most works on implantable antennas. We manufactured and tested the antenna in a liquid phantom which we replicated in the simulator for further comparison. The measured gain of the antenna reached the state-of-the-art values of 43.6 dBi, 25.8 dBi, and 20.1 dBi at 402MHz, 902MHz, and 2400MHz, respectively.

1 July 2019
Verified
Conference Paper
Closed access
NPNikta Pournoori
Nikta Pournoori
SMShubin Ma
Shubin Ma
LSLauri Sydanheimo
Lauri Sydanheimo
LULeena Ukkonen
Leena Ukkonen
TBToni Björninen
Toni Björninen
YRYahya Rahmat-Samii
Yahya Rahmat-Samii
We present a miniaturized dual-band implantable antenna using the planar inverted-F antenna (PIFA) structure for head-implant in biomedical telemetry systems resonating at 902 MHz and 2.4 GHz, the industrial, scientific and medical (ISM) bands. The topology of inserting slots into radiating patch and shorting it to the ground plane result in compact antenna size of 11×19×1.25 mm 3 . The proposed antenna is characterized and optimized based on full wave numerical simulations in the seven- layer human head model considering various parameters effects on the PIFAs design. Overall, we were able to achieve a broadband implantable antenna with the −26.71 dBi gain and radiation efficiency of 0.2% at 902 MHz and obtain −17.5 dBi gain with radiation efficiency of 0.31% at 2.4 GHz.

1 September 2019
Verified
Conference Paper
Closed access
SMShubin Ma
Shubin Ma
NPNikta Pournoori
Nikta Pournoori
LSLauri Sydanheimo
Lauri Sydanheimo
LULeena Ukkonen
Leena Ukkonen
TBToni Björninen
Toni Björninen
AGApostolos Georgiadis
Apostolos Georgiadis
Semi-passive RFID sensor possesses longer interrogation distance and advanced functionalities compared with the fully passive ones. Utilizing the wireless energy harvesting, we present a semi-passive RFID sensor platform without the reliance on the external battery. We outline the sensor system development and conduct the wireless measurement of the prototype to demonstrate its performance and functionality.

1 September 2018
Verified
Conference Paper
Closed access
NPNikta Pournoori
Nikta Pournoori
MKM. Waqas A. Khan
M. Waqas A. Khan
LULeena Ukkonen
Leena Ukkonen
TBToni Björninen
Toni Björninen
Radio frequency (RF) energy scavenging is a compelling approach to energize the low-power wireless devices. We present an energy harvesting system consists of a low-power RF switch circuitry and a passive UHF RFID tag. When the voltage at the storage capacitor terminals exceeds 0.58 V, RF switch connects the UHF RFID microchip to a dipole-type tag antenna. This way, an RFID reader can detect the charge storage level wirelessly with minimal power consumption at the harvester. In this paper, we detail the development of the system and present results from both simulations and measurement. Overall, we were able to achieve 0.58 V at the storage capacitor and detect the storage level indicator tag at the distance of 5.1 m in an experiment where regular 8.7 dBi patch antennas were connected to the harvester input and output of an RFID reader emitting 2.5 W EIRP.

1 July 2018
Verified
Conference Paper
Closed access
NPNikta Pournoori
Nikta Pournoori
MKM. Waqas. A. Khan
M. Waqas. A. Khan
LULeena Ukkonen
Leena Ukkonen
TBToni Björninen
Toni Björninen
This paper presents a radio frequency (RF) energy harvesting unit integrating a passive UHF RFID tag as a charge storage indicator. In this system, an energy harvesting unit converts the RF signal to DC and charges a storage capacitor. The RF switch, consists of a pin diode and UHF RFID tag, monitors the capacitor voltage and transmits signal to RFID reader if voltage at the capacitor terminals approaches 0.633 V. The proposed RF energy harvesting system operates at European UHF RFID spectrum from 865.7 MHz to 867.7 MHz. The experimental results indicate that 0.633 V at the capacitor terminals can be achieved with -5.5 dBm RF input power to the energy harvesting unit.

1 July 2026 in IEEE Journal of Microwaves
Verified
Journal Article
Open access
NPNikta Pournoori
Nikta Pournoori
AAAHMED ALBELTAGI
AHMED ALBELTAGI
TBToni Björninen
Toni Björninen
NONeea Oinas
Neea Oinas
JTJarkko Tolvanen
Jarkko Tolvanen
LULeena Ukkonen
Leena Ukkonen
Self-healing materials have emerged as key enablers for flexible and stretchable electronics, particularly in applications requiring resilience under repeated mechanical stress and autonomous recovery. In this work, we present the development and characterization of two fully self-healing passive UHF RFID elastomeric tag antennas, designed with diamond and elliptical slot geometries. Both antennas are fabricated on a soft self-healing elastomer substrate, and an electrically conductive liquid metal-based elastomer is employed as the conductive element. Compared to previous studies, a significant advancement in our work is the increase of the electrical conductivity of the self-healing radiator to ∼20 kS/m, which provides improved antenna impedance characteristics and proper radiation performance. Both antenna prototypes achieve read ranges between 5 to 6.7 m within the 860–960 MHz frequency band, aligning well with simulated results. Measurements after full antenna bisection show sub-minute recovery, with read range restored to 93–100% of the initial level within 60 seconds. The RFID chip is directly mounted onto the conductor without adhesives, preserving both electrical properties and mechanical recovery after physical damage. The attained results demonstrate the feasibility of constructing reliable and recoverable antenna systems entirely from self-healing materials and highlight their potential in the long-term deployment of soft and resilient wireless systems.