Francesco Lestini

Francesco Lestini

Auto-generated profile, based on publicly available information

Francesco Lestini

DICII - Tor Vergata University of Rome, Rome, Italy

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2024 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Open access
Giovanni Andrea CasulaGiovanni Andrea Casula
Giovanni Andrea Casula
FLFrancesco Lestini
Francesco Lestini
Francesco Paolo ChieteraFrancesco Paolo Chietera
Francesco Paolo Chietera
Giacomo MuntoniGiacomo Muntoni
Giacomo Muntoni
COCecilia Occhiuzzi
Cecilia Occhiuzzi
GMGaetano Marrocco
Gaetano Marrocco
This paper presents a compact AMC structure used as a shielding element for a generic wearable RFID tag at UHF frequencies for on-body applications, with an overall footprint limited to an area of only 0.03 λ 0 2 (41.4 mm × 82.8 mm). Thanks to the isolation provided by the AMC planar structure, the tag antenna gain and reading range are increased of about one order of magnitude in comparison with the case of a conventional tag attached to the human body. The designed antenna is platform tolerant, with a very good robustness and isolation with respect to the human body, exhibiting a high reliability. The AMC structure is implemented on a thin, flexible and biocompatible high permittivity silicon-doped dielectric substrate, with apertures both in the substrate and in the ground plane to allow skin transpiration. Therefore, the presented device can be effectively used also as an epidermal antenna, allowing the “on-skin” sampling of the most typical health parameters. The presented configuration has been designed using CST Studio Suite. A prototype has been fabricated and fully characterized, and measured results are in very good agreement with simulations.

8 August 2023 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
FLFrancesco Lestini
Francesco Lestini
NPNicoletta Panunzio
Nicoletta Panunzio
GMGaetano Marrocco
Gaetano Marrocco
COCecilia Occhiuzzi
Cecilia Occhiuzzi
Hyperthermia is an anti-cancer treatment that exploits the interaction between high-power electromagnetic fields and restricted regions of human tissues releasing a great amount of power to locally increase tissues temperature. Due to the high power, dangerous hot-spots may occur on the skin so that continuous monitoring of superficial temperature distribution is required. Thermal Monitoring Sheets (TMSs), which are grids of several wired temperature sensors, are currently used in clinical practice; however, they have some limitations in terms of poor spatial resolution, thermal conduction errors, and complex application procedures. Epidermal electronics associated with passive Ultra High Frequency (UHF) Radio Frequency IDentification (RFID) sensing technology could represent an attractive alternative thanks to its wireless nature and limited invasiveness. In this framework, this article proposes an innovative TMS based on battery-less RFID sensors (R-TMS). It comprises a planar grid of circular loop antennas with temperature-sensing-oriented ICs that can sample skin temperature without interfering with hyperthermia treatment. The system proved capable of monitoring skin temperature via wireless data transmission with a higher spatial resolution that state-of-the-art devices. The physical rationale, the design, and the experimentation of the R-TMS are here presented to validate the proposed approach and evaluate its feasibility from the electromagnetic perspective.

17 April 2024 in IEEE Journal of Radio Frequency Identification
Verified
Journal Article
Closed access
FLFrancesco Lestini
Francesco Lestini
GMGaetano Marrocco
Gaetano Marrocco
COCecilia Occhiuzzi
Cecilia Occhiuzzi
Modern wireless communication systems are becoming increasingly necessary, emphasizing the need for electromagnetic devices that can flexibly operate under different conditions, e.g., under power constraints or in hostile environments where scattering objects randomly modify coverage areas and communication links. Due to their ability to dynamically change operating frequency, radiation pattern, bandwidth characteristics, and polarization, reconfigurable objects (especially antennas and backscattering surfaces) have received significant attention in this context. Electromagnetic features can be electronically selected by controlling the bias voltage of tunable elements adequately integrated into the layout. Usually, this is done by employing external programmable controllers that need power sources and wired connections, leading to unusable configurations for several scenarios. Thus, exploring alternative electronic tuning mechanisms becomes essential. This paper proposes RFID-Based Reconfigurable Electromagnetic Devices as a wireless, cost-effective, and low-power solution. The system’s operating principle, potential architectures, and applicability in practical scenarios are presented. Theoretical and experimental analysis validate the proposed architecture, whose capabilities are finally demonstrated by prototyping and testing two reconfigurable antenna arrays.

17 September 2025 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
FLFrancesco Lestini
Francesco Lestini
GMGaetano Marrocco
Gaetano Marrocco
COCecilia Occhiuzzi
Cecilia Occhiuzzi
Implantable Medical Devices (IMDs) such as pacemakers and defibrillators increasingly rely on wireless connectivity for remote monitoring and programming. However, this wireless access introduces significant cybersecurity and physical vulnerabilities, making IMDs susceptible to unauthorized access and electromagnetic interference (EMI). This paper proposes a wirelessly programmable smart shield based on a reconfigurable Frequency Selective Surface (P-FSS) as a novel defense mechanism for IMD security. The shield dynamically transitions between shielding and transparency states, passively controlled by an RFID-powered circuit, ensuring protection from malicious attacks while enabling authorized medical communication. This study extends prior theoretical investigations by introducing a fully functional prototype, realized with a rigorous design methodology and leveraging low-power varactor-based switching to enhance efficiency and miniaturize the size. The system demonstrates over 40 dB of shielding effectiveness in the Medical Implant Communication Service (MICS) band (401–406 MHz) while allowing controlled transparency via a battery-less RFID interface with an activation distance of 0.6 m. Experimental validation confirms the practical feasibility of the proposed approach, making it a viable solution for enhancing the cyber-physical security of IMDs.

16 July 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Emanuele RasoEmanuele Raso
Emanuele Raso
FNFrancesca Nanni
Francesca Nanni
FLFrancesco Lestini
Francesco Lestini
Lorenzo BraccialeLorenzo Bracciale
Lorenzo Bracciale
GPGiorgia Panico
Giorgia Panico
Pierpaolo LoretiPierpaolo Loreti
Pierpaolo Loreti
The healthcare industry is witnessing a rapid rise in the adoption of wearable and implantable medical devices, including advanced electrochemical sensors and other smart diagnostic technologies. These devices are increasingly used to enable real-time monitoring of physiological parameters, allowing for faster diagnosis and more personalized care plans. Their growing presence reflects a broader shift toward smart connected healthcare systems aimed at delivering immediate and actionable insights to both patients and medical professionals. At the same time, the healthcare industry is increasingly targeted by cyberattacks, primarily due to the high value of medical information; in addition, the growing integration of ICT technologies into medical devices has introduced new vulnerabilities that were previously absent in this sector. To mitigate these risks, new international guidelines advocate the adoption of best practices for secure software development, emphasizing a security-by-design approach in the design and implementation of such devices. However, the vast and fragmented nature of the information required to effectively support these development processes poses a challenge for the numerous stakeholders involved. In this paper, we demonstrate how key features of the Malware Information Sharing Platform (MISP) can be leveraged to systematically collect and structure vulnerability-related information for medical devices. We propose tailored structures, objects, and taxonomies specific to medical devices, facilitating a standardized data representation that enhances the security-by-design development of these devices.

18 August 2025 in IEEE Antennas and Propagation Magazine
Verified
Journal Article
Closed access
COCecilia Occhiuzzi
Cecilia Occhiuzzi
FLFrancesco Lestini
Francesco Lestini
AMAlessio Mostaccio
Alessio Mostaccio
FNFederica Naccarata
Federica Naccarata
FNFrancesca M. C. Nanni
Francesca M. C. Nanni
GMGaetano Marrocco
Gaetano Marrocco
The evolution of prosthetics has been significantly shaped by advancements in biomedical engineering and state-of-the-art technologies. A notable breakthrough in this domain is the emergence of wireless implantable devices, representing a transformative shift in implant design and functionality. These prostheses aim to restore lost functionalities and seamlessly integrate with the human body, offering therapeutic and diagnostic capabilities when equipped with embedded sensors. However, wireless prostheses require through-the-body communication links with external readers, achieved through minimal structural alterations to preserve core functionalities and without batteries and complex electronics for biocompatibility and miniaturization. Such challenges can be addressed through two approaches: utilizing the prosthesis structure as a radiating element according to the paradigm of structural antennas and employing passive battery-less communication platforms operating in backscattering. The feasibility of these approaches, focusing on the ultrahigh-frequency (UHF) band (860–960 MHz), is demonstrated in this article through theoretical formalization, case studies, and in vitro measurements, with insights into materials and manufacturing processes provided.