Zihuan Liu

Zihuan Liu

Auto-generated profile, based on publicly available information

Zihuan Liu

University of Texas at Austin

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YMYuqi Meng
Yuqi Meng
EVEhsan Vatankhah
Ehsan Vatankhah
XNXiaoyu Niu
Xiaoyu Niu
ZLZihuan Liu
Zihuan Liu
NHNeal A. Hall
Neal A. Hall
Silicon photonics has emerged as a popular platform for building sensors that can perform a wide range of measurements with high sensitivity. Here an optical accelerometer in silicon photonics platform was designed, and a fabricated device’s performance was characterized using integrated thermal electric modulators and shaker tests. The device operation is based on the balanced Mach-Zehnder interferometer (MZI) that resides in the top layers of a silicon chip. The chip is packaged to form a cantilever beam. As the chip undergoes acceleration, the reference arm of an MZI maintains stationary phase while the sensing arm bends. Multiple loops of serpentine waveguides were used to increase sensitivity. When light from the reference and sensing arms are combined, the output light has an intensity that is modulated by the imparted acceleration. These intensity variations are detected by a fiber coupled photodetector. An analytical model is presented combining optical and mechanical subsystems and is used to identify small designs with sub 10ng/√Hz noise floor. The sensor can transmit analog sensor data over long distances via the attached fiber array, making the sensor attractive for deep subsurface seismic measurements running several kms underground at elevated temperatures.

2 April 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
VCVakhtang Chulukhadze
Vakhtang Chulukhadze
ZLZihuan Liu
Zihuan Liu
ZYZiqian Yao
Ziqian Yao
LMLezli Matto
Lezli Matto
THTzu-Hsuan Hsu
Tzu-Hsuan Hsu
RLRuochen Lu
Ruochen Lu
Piezoelectric micromachined ultrasonic transducers (PMUTs) are widely utilized in applications that demand mechanical resilience, thermal stability, and compact form factors. Recent efforts have sought to demonstrate that single-crystal lithium niobate (LN) is a promising PMUT material platform, offering high electromechanical coupling (k2) and bidi-rectional performance. In addition, advances in LN film transfer technology have enabled high quality periodically poled piezoelectric films (P3F), facilitating a bimorph piezoelectric stack without intermediate electrodes. In this work, we showcase a bimorph PMUT incorporating a mechanically robust, 20 μm thick P3F LN active layer. We establish the motivation for LN PMUTs through a material comparison, followed by extensive membrane geometry optimization and subsequent enhancement of the PMUT’s k2. We demonstrate a 775 kHz flexural mode device with a quality factor (Q) of 200 and an extracted k2 of 6.4%, yielding a high transmit efficiency of 65 nm/V with a mechanically robust active layer. We leverage the high performance to demonstrate extreme-temperature resilience, showcasing stable device operation up to 600 °C and survival up to 900 °C, highlighting LN’s potential as a resilient PMUT platform.

3 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XNXiaoyu Niu
Xiaoyu Niu
VCVakhtang Chulukhadze
Vakhtang Chulukhadze
ZLZihuan Liu
Zihuan Liu
EVEhsan Vatankhah
Ehsan Vatankhah
YWYinan Wang
Yinan Wang
NHNeal A. Hall
Neal A. Hall
A bimorph lithium niobate (LiNbO3, LN) transducer has been proposed as a microphone. Surface electrodes sense the lateral in-plane electric field in thin LN films resulting from out-of-plane deformation due to acoustic pressure. The bimorph is implemented using LN films with opposing polarization, achieved with a wafer bonding approach. The article summarizes our work on an LN microphone using an LN diaphragm with $300~\mu $ m thickness and a quarter-inch diameter. Laser Doppler vibrometer (LDV) measurements are performed using piezoelectric excitation of the diaphragm to characterize mode shapes of the diaphragm. Pitch-catch acoustic measurements are performed in the air using tone burst waveforms. We characterized acoustic sensitivity and noise floor. Lumped element and finite element analysis (FEA) are used to predict the acoustical performance. This is the first work demonstrating LN material in microphone applications. We ultimately envision using a bimorph LN film with $2~\mu $ m thickness in total on the silicon substrate, where an approximately $1\times 1$ mm diaphragm is formed via a backside through wafer etch. A rigorous lumped element model is used to simulate the LN microelectromechanical systems (MEMS) microphone with a 73.58-dB signal-to-noise ratio (SNR). Improving MEMS microphone SNR beyond the current state-of-the-art is challenging. LN microphones may be a viable path.

1 May 2023 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
EVEhsan Vatankhah
Ehsan Vatankhah
YMYuqi Meng
Yuqi Meng
ZLZihuan Liu
Zihuan Liu
XNXiaoyu Niu
Xiaoyu Niu
NHNeal A. Hall
Neal A. Hall
The majority of reported measurements on high intensity ultrasound beams in air are below 40 kHz and performed on standing waves inside of a guide. Here, experimental characterization of high intensity progressive and divergent sound beams in air at 300 kHz are presented. Measurements in this frequency range are challenging. Accurate characterization of high intensity sound beams requires a measurement bandwidth at least ten times the beam's primary frequency, as high intensity soundwaves steepen and form shocks and, therefore, contain significant signal power at harmonic frequencies. Hence, a measurement bandwidth of at least 3 MHz is required. Calibrated measurement microphones are generally not available in this frequency range. This limitation has been overcome by using a hydrophone with a calibrated response from 250 kHz to 20 MHz. A narrowband piezoelectric transducer is used as the source in this study, and it is capable of generating tone burst waveforms centered at 300 kHz with 160 dB sound pressure level surface pressure. Cumulative wave steepening and shock formation are observed in on-axis measurements. The source's surface vibration profile is measured using a scanning laser Doppler vibrometer, and the vibration profile is imported into a numerical wide-angle Khokhlov-Zabolotskaya-Kuznetsov simulation for comparison against measured on-axis waveforms.

14 May 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XNXiaoyu Niu
Xiaoyu Niu
CSCarly A. Stalder
Carly A. Stalder
ZLZihuan Liu
Zihuan Liu
YMYuqi Meng
Yuqi Meng
EVEhsan Vatankhah
Ehsan Vatankhah
NHNeal A. Hall
Neal A. Hall
The remarkable directional hearing capabilities of the fly Ormia ochracea have inspired advancements in acoustic sensing technologies. Despite the small size of the fly’s ear relative to the wavelength of audible sound, it can precisely locate crickets by detecting their chirps. This article presents the design, fabrication, testing, andmodeling of a biologically inspired MEMS microphone that leverages the fly’s unique hearing mechanism. The device consists of a two-sided cantilever beam that rotates about torsional pivots, producing two primary vibration modes: (1) a rocking mode, which responds to pressure gradients with out-of-phase motion for sound localization, and (2) a bending mode, which reacts to omnidirectional sound pressure with in-phase motion. The microphone is fabricated using a silicon-on-insulator wafer with a 2-μm-thick device layer and incorporates a 500-nm-thick aluminum nitride piezoelectric film for transduction. Multipoint scans validate the sensing modes, which are accurately modeled using finite element analysis. Signal readout is achieved through an integrated circuit amplifier with high bias resistance. Acoustic measurements in air are performed across audible and ultrasonic frequencies, with sensitivity results compared to simulations. The initial prototypes demonstrate optimal performance at ultrasonic frequencies near 20 kHz. Simulations further explore potential designs for broadband applications spanning the audio frequency range of 20 Hz to 20 kHz.

20 October 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XNXiaoyu Niu
Xiaoyu Niu
ZLZihuan Liu
Zihuan Liu
YMYuqi Meng
Yuqi Meng
EVEhsan Vatankhah
Ehsan Vatankhah
DKDonghwan Kim
Donghwan Kim
NHNeal A. Hall
Neal A. Hall
This work presents a novel MEMS microphone inspired by the mechanically coupled tympana of the parasitoid fly Ormia ochracea, capable of simultaneously measuring omnidirectional pressure and two orthogonal in-plane pressure gradients. The device features a circular lead zirconate titanate (PZT)-on-silicon diaphragm supported by circumferential springs, with integrated piezoelectric sensing elements operating in the 3–1 mode. Using a laser Doppler vibrometer (LDV), we identified and imaged three distinct vibration modes at 1490, 2055, and 4255 Hz, each selectively responsive to either omnidirectional pressure or pressure gradients along orthogonal axes. The microphone was integrated with commercial low-noise integrated circuit amplifiers (ICAs) and packaged within a custom Faraday cage for electromagnetic shielding. Acoustic characterization in an anechoic chamber demonstrated the ability to decouple and independently measure the three pressure components, with sensitivity and directivity modeled and validated against experimental results. To our knowledge, this is the first MEMS microphone to achieve simultaneous measurement of pressure and its gradients along two orthogonal axes, enabling advanced source localization and improved performance in noisy environments.