7 February 2021 in European Journal of Nuclear Medicine and Molecular Imaging
Purpose: CXCR4 (over)expression is found in multiple human cancer types, while expression is low or absent in healthy tissue. In glioblastoma it is associated with a poor prognosis and more extensive infiltrative phenotype. CXCR4 can be targeted by the diagnostic PET agent [68Ga]Ga-Pentixafor and its therapeutic counterpart [177Lu]Lu-Pentixather. We aimed to investigate the expression of CXCR4 in glioblastoma tissue to further examine the potential of these PET agents. Methods: CXCR4 mRNA expression was examined using the R2 genomics platform. Glioblastoma tissue cores were stained for CXCR4. CXCR4 staining in tumor cells was scored. Stained tissue components (cytoplasm and/or nuclei of the tumor cells and blood vessels) were documented. Clinical characteristics and information on IDH and MGMT promoter methylation status were collected. Seven pilot patients with recurrent glioblastoma underwent [68Ga]Ga-Pentixafor PET; residual resected tissue was stained for CXCR4. Results: Two large mRNA datasets (N = 284; N = 540) were assesed. Of the 191 glioblastomas, 426 cores were analyzed using immunohistochemistry. Seventy-eight cores (23 tumors) were CXCR4 negative, while 18 cores (5 tumors) had both strong and extensive staining. The remaining 330 cores (163 tumors) showed a large inter- and intra-tumor variation for CXCR4 expression; also seen in the resected tissue of the seven pilot patients—not directly translatable to [68Ga]Ga-Pentixafor PET results. Both mRNA and immunohistochemical analysis showed CXCR4 negative normal brain tissue and no significant correlation between CXCR4 expression and IDH or MGMT status or survival. Conclusion: Using immunohistochemistry, high CXCR4 expression was found in a subset of glioblastomas as well as a large inter- and intra-tumor variation. Caution should be exercised in directly translating ex vivo CXCR4 expression to PET agent uptake. However, when high CXCR4 expression can be identified with [68Ga]Ga-Pentixafor, these patients might be good candidates for targeted radionuclide therapy with [177Lu]Lu-Pentixather in the future.
6 June 2024 in NMR in Biomedicine
The neuronal tricarboxylic acid and glutamate/glutamine (Glu/Gln) cycles play important roles in brain function. These processes can be measured in vivo using dynamic 1H–[13C] MRS during administration of 13C‐labeled glucose. Proton‐observed carbon‐edited (POCE) MRS enhances the signal‐to‐noise ratio (SNR) compared with direct 13C‐MRS. Ultra‐high field further boosts the SNR and increases spectral dispersion; however, even at 7 T, Glu and Gln 1H‐resonances may overlap. Further gain can be obtained with selective POCE (selPOCE). Our aim was to create a setup for indirect dynamic 1H–[13C] MRS in the human brain at 7 T. A home‐built non‐shielded transmit–receive 13C‐birdcage head coil with eight transmit–receive 1H‐dipole antennas was used together with a 32‐channel 1H‐receive array. Electromagnetic simulations were carried out to ensure that acquisitions remained within local and global head SAR limits. POCE‐MRS was performed using slice‐selective excitation with semi‐localization by adiabatic selective refocusing (sLASER) and stimulated echo acquisition mode (STEAM) localization, and selPOCE‐MRS using STEAM. Sequences were tested in a phantom containing non‐enriched Glu and Gln, and in three healthy volunteers during uniformly labeled 13C‐glucose infusions. In one subject the voxel position was alternated between bi‐frontal and bi‐occipital placement within one session. [4‐13C]Glu‐H4 and [4‐13C]Gln‐H4 signals could be separately detected using both STEAM‐POCE and STEAM‐selPOCE in the phantom. In vivo, [4,5‐13C]Glx could be detected using both sLASER‐POCE and STEAM‐POCE, with similar sensitivities, but [4,5‐13C]Glu and [4,5‐13C]Gln signals could not be completely resolved. STEAM‐POCE was alternately performed bi‐frontal and bi‐occipital within a single session without repositioning of the subject, yielding similar results. With STEAM‐selPOCE, [4,5‐13C]Glu and [4,5‐13C]Gln could be clearly separated. We have shown that with our setup indirect dynamic 1H–[13C] MRS at 7 T is feasible in different locations in the brain within one session, and by using STEAM‐selPOCE it is possible to separate Glu from Gln in vivo while obtaining high quality spectra.
31 August 2022 in European Radiology Experimental
Objectives: Acoustic noise in magnetic resonance imaging (MRI) negatively impacts patients. We assessed a silent gradient coil switched at 20 kHz combined with a T1-weighted magnetisation prepared rapid gradient-echo (MPRAGE) sequence at 7 T. Methods: Five healthy subjects (21–29 years; three females) without previous 7-T MRI experience underwent both a quiet MPRAGE (Q-MPRAGE) and conventional MPRAGE (C-MPRAGE) sequence twice. Image quality was assessed quantitatively, and qualitatively by two neuroradiologists. Sound level was measured objectively and rated subjectively on a 0 to 10 scale by all subjects immediately following each sequence and after the whole examination (delayed). All subjects also reported comfort level, overall experience and willingness to undergo the sequence again. Results: Compared to C-MPRAGE, Q-MPRAGE showed higher signal-to-noise ratio (10%; p = 0.012) and lower contrast-to-noise ratio (20%; p < 0.001) as well as acceptable to good image quality. Q-MPRAGE produced 27 dB lower sound level (76 versus 103 dB). Subjects reported lower sound level for Q-MPRAGE both immediate (4.4 ± 1.4 versus 6.4 ± 1.3; p = 0.007) and delayed (4.6 ± 1.4 versus 6.3 ± 1.3; p = 0.005), while they rated comfort level (7.4 ± 1.0 versus 6.1 ± 1.7; p = 0.016) and overall experience (7.6 ± 1.0 versus 6.0 ± 0.9; p = 0.005) higher. Willingness to undergo the sequence again was also higher, however not significantly (8.1 ± 1.0 versus 7.2 ± 1.3; p = 0.066). Conclusion: Q-MPRAGE using a silent gradient coil reduced sound level by 27 dB compared to C-MPRAGE at 7 T while featuring acceptable-to-good image quality and a quieter and more pleasant subject experience.
9 April 2025 in NMR in Biomedicine
Glutamate (Glu) is the major excitatory neurotransmitter in the central nervous system. The measurement of Glu/glutamine (Gln) neurotransmitters in the brain provides valuable insights into the dynamic aspects of neuroenergetics and neurotransmitter cycles and can be accomplished through the detection of 13C‐labeling of Glu and Gln during the administration of 13C‐labeled glucose. Our goal is to evaluate the reproducibility of selective proton‐observed, carbon‐edited (selPOCE) MRS at 7 T for the detection of 13C‐labeled Glu and Gln in the human brain. Data of three healthy participants, who were scanned twice at 7 T while undergoing [U‐13C]‐glucose infusion for 120 min, were used to detect 13C‐labeled Glu and Gln in the brain, using selPOCE‐STEAM‐MRS. There was a rapid increase of plasma glucose 13C fractional enrichment (FE) during the first 20 min of infusion, followed by a steady state of plasma glucose 13C FE until the end of the [U‐13C]‐glucose infusion. The time courses of 13C‐labeling of Glu and Gln were similar for test/retest. The test/retest variability was 15.8% for 13C‐Glu and 33.3% for 13C‐Gln. Knowing the variability of these readings using selPOCE‐STEAM‐MRS can inform the application to future studies on disease‐specific alterations in Glu/Gln cycling.
1 September 2021 in Epilepsie, periodiek voor professionals
De relatief lage sensitiviteit en specificiteit van conventionele MRI zorgt voor suboptimale beeldvorming van het epileptogene gebied. 7T metabole MRI kan hier verandering in brengen door middel van een hogere magnetische veldsterkte en de mogelijkheid tot het afbeelden van specifieke moleculen/metabolieten die behoren tot het metabole fenotype van de oorzaak van de epilepsie.
12 January 2026 in Neuro-Oncology Advances
Background: Magnetic resonance spectroscopy (MRS) complements conventional MRI in brain tumor diagnosis by measuring metabolites associated with various molecular pathways. However, inconsistent and inaccurate voxel placement, due to limited experience and time constraints, has hindered its clinical use. There is a critical need for greater precision and efficiency in MRS voxel placement, which could be addressed by an algorithm leveraging tumor anatomy to facilitate the automation of this process. This pilot study aimed to design and validate an automated, AI-driven MRS voxel placement tool to evaluate suspected diffuse gliomas. Methods: In this pilot study, the MRS single voxel auto-placement algorithm utilizes tumor sub-compartment segmentation from a pre-trained deep learning model. Preprocessing involves co-registration and isotropic resampling of multiparametric MRI. The algorithm iteratively adjusts the position and rotation of an MRS voxel mask over the segmented images to maximize enhancing tumor core inclusion while excluding necrosis. Two board-certified neuroradiologists independently and blindly assessed algorithm- and clinically-placed MRS voxels (n = 14) using a Likert scale. Results: Fourteen cases of MRS single-voxel placement were evaluated (median age and interquartile range, 47 years [24-64 years]; male, 10 patients [71%]). Overall quality ratings of 4 or 5 were assigned to 75% of clinically placed voxels and 79% of algorithm-placed voxels, without any statistical difference (P = .56). Similarly, no statistically significant differences were observed in position ratings (P = .30) or rotation ratings (P = .51). Conclusions: No statistically significant differences were observed between algorithm- and clinically placed voxels, highlighting the promise of AI-based automated MRS single-voxel placement.