Fossil energy sources are dwindling. It is necessary to develop alternative energy sources for future energy. The solar cell is an alternative energy that can be used in Indonesia. The current challenge is utilizing solar panels for the best possible power production. This research gives the solution to design an increase in solar cell output power by using mirrors, cooling, and a double-axis solar tracking control system. The results show that using a mirror, cooling, and double-axis solar tracking produces optimal output power with a current and power are 2.43 amperes and 40.3 watts, respectively. Meanwhile, several factors can affect this solar panel's efficiency. Specifically, the amount of solar radiation that the solar panel can receive depends on the climate on the day and location of the research and the solar panel's dimensions.
15 August 2022 in IEEE Transactions on Plasma Science
We have developed a portable ozone-mist spraying system as one of the potential ozone applications in agriculture because ozone effectively sterilizes viruses, bacteria, and pests. The previous works developed the ozone-mist spraying system using dielectric barrier discharge (DBD) and a nozzle. The study confirmed that ozone-mist spray could control the pest in a short time with a very high ozone concentration that becomes a possible promising insecticidal method for agriculture. However, it is required to improve the ozone-mist spray system by controlling it to a target plant easily and effectively. This work developed a water-cooling DBD spraying nozzle, which improves the conventional ozone-mist spraying system by applying an electric field to the ring electrode. The ozone-mist nozzle’s ozone concentration and sterilization effect in which a water-cooling grounded electrode and a high-voltage electrode were incorporated were evaluated. Additionally, the specific charge of ozone-mist was studied by placing a ring electrode for induction charging. It was found that induction charging of ozone-mist could increase the efficient attachment of ozone ist to targets by applying a dc voltage to the additional ring electrode.
1 April 2024 in International Journal of Electrical and Computer Engineering (IJECE)
Power quality is a major issue in the power transfer process. This is caused by disturbances such as voltage sags, voltage spikes, and harmonics. Voltage sag is the most common disturbance in the electric power system. However, the dynamic voltage restorer (DVR) is the most effective device for voltage sags. This research uses the DVR to overcome voltage sags using fuzzy logic controller (FLC) and battery energy storage system (BESS) to improve the performance of the DVR. The results showed that DVR using FLC improved the quality of voltage recovery compared to BESS because FLC injected a greater voltage of 0.0991 pu than BESS.
1 August 2023 in International Journal of Electrical and Computer Engineering (IJECE)
Poor performance of the motor drive system is caused when the direct current-link (DC-link) capacitor voltages of the inverter are not sufficiently generated. This is mainly because of the various load torque changes and input voltage fluctuation. The qZ-source inverter operates with a fully shoot-through technique. This technique causes mismatching between the upper and lower DC-link capacitor voltages. Without capacitor voltage-balancing function, the desired DC-link capacitor voltages could not be provided or maintained when there are load and speed changes. A Sawtooth carrier-based simple boost triple-sixty-degree (TSD) pulse width modulation (PWM) technique is used to drive the qZ-source T-type inverter because this technique can give a more significant boost DC-link voltage than a traditional simple boost PWM technique. Proportional integral (PI) controller is applied for the DC-link voltage controller to achieve the fast response and less steady-state error. The simulation model was constructed for a 4 kW, 400 V, 1,400 rpm induction motor (IM) drive system used in rolling mill using MATLAB/Simulink with and without voltage balancing function. As a result, DC-link voltages of the qZ-source T-type inverter fed the induction motor drive system could be controlled using a capacitor voltage-balancing function and the output power of the motor from the simulation result is approximately equal to 4 kW.