Yulin Yang

Yulin Yang

Auto-generated profile, based on publicly available information

Yulin Yang

Department of Biomedical Engineering, Xiangya School of Basic Medical Sciences, Central South University, Changsha, 410013, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2025 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MDMingming Ding
Mingming Ding
YYYulin Yang
Yulin Yang
NSNan Sun
Nan Sun
YHYilong He
Yilong He
ZDZhuxin Dong
Zhuxin Dong
BTBo Tian
Bo Tian

16 December 2024 in Applied Physics Letters
Verified
Journal Article
Closed access
YYYulin Yang
Yulin Yang
JCJiajun Cui
Jiajun Cui
XCXinchao Cui
Xinchao Cui
WLWenzhong Liu
Wenzhong Liu
BTBo Tian
Bo Tian
JZJing Zhong
Jing Zhong
Magnetic nanoparticle (MNP) agglutination-based optomagnetic biosensing has been applied for rapid and sensitive detection of various biomolecules. However, the underlying physics of optomagnetic biosensing remains a hurdle, especially when the size of MNPs approaches the laser wavelength, i.e., the scattering enters the Mie regime. In this study, we propose a numerical model by combining the Fokker–Planck equation and the T-matrix to explain the effect of Mie scattering on the optomagnetic signal of the agglutinated MNPs. It indicates that the orientation-dependent Mie scattering of the MNP dimer leads to an inverse optomagnetic response compared to that of the MNP monomer. The inverse optomagnetic response can dominate with the enhancement of Mie scattering. To verify the numerical model, biotinylated bovine serum albumin (biotin-BSA) is applied to agglomerate streptavidin-coated MNPs in a standard biosensing strategy representing the immuno-agglutination assay. Guided by the model, a proportion-based signal analysis is proposed to improve the performance of the MNP agglutination-based optomagnetic biosensor, which provides a picomolar detection limit for biotin-BSA (∼0.1 ng/mL) with a total assay time of 8 min, paving the way for more accurate point-of-care diagnosis.

17 September 2025 in Analytica Chimica Acta
Verified
Journal Article
Closed access
NSNan Sun
Nan Sun
TLTingting Li
Tingting Li
YYYulin Yang
Yulin Yang
ZCZhenhua Chen
Zhenhua Chen
QGQian Gao
Qian Gao
BTBo Tian
Bo Tian

9 April 2026 in Analytical Chemistry
Verified
Journal Article
Closed access
QBQin Bi
Qin Bi
YYYulin Yang
Yulin Yang
LSLiyang Shi
Liyang Shi
XLXinli Liu
Xinli Liu
ZZZheyuan Zhou
Zheyuan Zhou
BTBo Tian
Bo Tian

16 July 2026 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
QBQin Bi
Qin Bi
YYYulin Yang
Yulin Yang
BTBing Tan
Bing Tan
BTBo Tian
Bo Tian
WLWenen Liu
Wenen Liu

7 October 2026 in ACS Nano
Verified
Journal Article
Closed access
YYYulin Yang
Yulin Yang
QBQin Bi
Qin Bi
KQKe Qin
Ke Qin
GJGuang Jia
Guang Jia
QGQian Gao
Qian Gao
BTBo Tian
Bo Tian